Large eddy simulation of wind-induced interunit dispersion around multistory buildings

被引:54
作者
Ai, Z. T. [1 ]
Mak, C. M. [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
关键词
Interunit dispersion; Airborne infection; Timescales; Multistory buildings; Large eddy simulation; Computational fluid dynamics; HIGHRISE RESIDENTIAL BUILDINGS; INDUCED AIR-FLOW; POLLUTANT DISPERSION; AIRBORNE TRANSMISSION; INDOOR ENVIRONMENTS; CFD SIMULATION; NUMERICAL-SIMULATION; AEROSOL TRANSMISSION; NATURAL VENTILATION; MEAN CONCENTRATION;
D O I
10.1111/ina.12200
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Previous studies regarding interunit dispersion used Reynolds-averaged Navier-Stokes (RANS) models and thus obtained only mean dispersion routes and re-entry ratios. Given that the envelope flow around a building is highly fluctuating, mean values could be insufficient to describe interunit dispersion. This study investigates the wind-induced interunit dispersion around multistory buildings using the large eddy simulation (LES) method. This is the first time interunit dispersion has been investigated transiently using a LES model. The quality of the selected LES model is seriously assured through both experimental validation and sensitivity analyses. Two aspects are paid special attention: (i) comparison of dispersion routes with those provided by previous RANS simulations and (ii) comparison of timescales with those of natural ventilation and the survival times of pathogens. The LES results reveal larger dispersion scopes than the RANS results. Such larger scopes could be caused by the fluctuating and stochastic nature of envelope flows, which, however, is canceled out by the inherent Reynolds-averaged treatment of RANS models. The timescales of interunit dispersion are comparable with those of natural ventilation. They are much shorter than the survival time of most pathogens under ordinary physical environments, indicating that interunit dispersion is a valid route for disease transmission.
引用
收藏
页码:259 / 273
页数:15
相关论文
共 77 条
[1]   On-site measurements of ventilation performance and indoor air quality in naturally ventilated high-rise residential buildings in Hong Kong [J].
Ai, Z. T. ;
Mak, C. M. ;
Cui, D. J. .
INDOOR AND BUILT ENVIRONMENT, 2015, 24 (02) :214-224
[2]   Modeling of coupled urban wind flow and indoor air flow on a high-density near-wall mesh: Sensitivity analyses and case study for single-sided ventilation [J].
Ai, Z. T. ;
Mak, C. M. .
ENVIRONMENTAL MODELLING & SOFTWARE, 2014, 60 :57-68
[3]   Analysis of fluctuating characteristics of wind-induced airflow through a single opening using LES modeling and the tracer gas technique [J].
Ai, Z. T. ;
Mak, C. M. .
BUILDING AND ENVIRONMENT, 2014, 80 :249-258
[4]   A study of interunit dispersion around multistory buildings with single-sided ventilation under different wind directions [J].
Ai, Z. T. ;
Mak, C. M. .
ATMOSPHERIC ENVIRONMENT, 2014, 88 :1-13
[5]   CFD simulation of flow and dispersion around an isolated building: Effect of inhomogeneous ABL and near-wall treatment [J].
Ai, Z. T. ;
Mak, C. M. .
ATMOSPHERIC ENVIRONMENT, 2013, 77 :568-578
[6]   Numerical investigation of wind-induced airflow and interunit dispersion characteristics in multistory residential buildings [J].
Ai, Z. T. ;
Mak, C. M. ;
Niu, J. L. .
INDOOR AIR, 2013, 23 (05) :417-429
[7]  
[Anonymous], 1994, MMWR Recomm Rep, V43, P1
[8]  
[Anonymous], 2010, ANSYS FLUENT 13 0 TH
[9]  
[Anonymous], 1975, TURBULENCE
[10]   Spread and prevention of some common viral infections in community facilities and domestic homes [J].
Barker, J ;
Stevens, D ;
Bloomfield, SF .
JOURNAL OF APPLIED MICROBIOLOGY, 2001, 91 (01) :7-21