Computer-aided diagnosis for 3-dimensional breast ultrasonography

被引:26
|
作者
Chen, DR
Chang, RF
Chen, WM
Moon, WK
机构
[1] China Med Coll & Hosp, Dept Gen Surg, Taichung, Taiwan
[2] Natl Chung Cheng Univ, Dept Comp Sci & Informat Engn, Chiayi, Taiwan
[3] Seoul Natl Univ Hosp, Dept Diagnost Radiol, Seoul 110744, South Korea
关键词
D O I
10.1001/archsurg.138.3.296
中图分类号
R61 [外科手术学];
学科分类号
摘要
Hypothesis: Using 3-dimensional (3-D) over 2-dimensional (2-D) ultrasonographic (US) images of the breast represents a potentially significant advantage for computer-aided diagnosis (CAD). Background: Although conventional 2-D US images of the breast are increasingly used in surgical, clinical practice, 3-D US imaging of the breast, a newly introduced technique, can offer more information than 2-D US images do. Design: This study deals with a I CAD method for use with the proposed 3-D US images of the breast and compares its performance with conventional 2-D US versions. Methods: The test databases included 3-D US images of 107 benign and 54 malignant breast tumors for a total of 161 US images. All solid nodules at US belong to categories above C3 (ie, probably benign). The 3-D US imaging was performed using a scanner (Voluson 530; kretz Technik, Zipf, Austria). New 3-D autocorrelation coefficients extended from the traditional 2-D autocorrelations were developed to extract the texture characteristics of the 3-D US images. The extracted texture features of the 3-D US images were used to classify the tumor as benign or malignant using the neural network. Results: At the receiver operating characteristic analysis, 3-D and 2-D autocorrelation calculating schemes yielded Az values (ie, area under the receiver operating characteristic curve) of 0.97 and 0.85 in distinguishing between benign and malignant lesions, respectively. Accuracy, sensitivity, specificity, positive predictive value, and negative predictive value are statistically significantly improved using 3-D instead of 2-D US images for CAD. Conclusions: The proposed system (for 3-D and 2-D CAD) is expected. to be a useful computer-aided diagnostic tool for classifying benign and malignant tumors on ultrasonograms and can provide a second reading to help reduce misdiagnosis. Findings from this study suggest that using 3-D over 2-D US images for CAD represents a potentially significant advantage.
引用
收藏
页码:296 / 302
页数:7
相关论文
共 50 条
  • [41] COMPUTER-AIDED 3-DIMENSIONAL RECONSTRUCTION OF GUINEA-PIG COCHLEAR AQUEDUCT
    TORIYA, R
    ARIMA, T
    KURAOKA, A
    UEMURA, T
    ACTA OTO-LARYNGOLOGICA, 1991, 111 (05) : 917 - 920
  • [42] COMPUTER-AIDED 3-DIMENSIONAL RECONSTRUCTION AND MEASUREMENT OF THE VESTIBULAR END-ORGANS
    TAKAGI, A
    SANDO, I
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1988, 98 (03) : 195 - 202
  • [43] COMPUTER-AIDED ANALYSIS OF 3-DIMENSIONAL RADIOPHARMACEUTICAL DISTRIBUTIONS IN SERIAL ECT ACQUISITIONS
    SCHLUSSELBERG, DS
    LEWIS, MH
    SIMON, TR
    JOURNAL OF NUCLEAR MEDICINE, 1984, 25 (05) : P90 - P91
  • [44] BLASTCAD - NORANDA 3-DIMENSIONAL COMPUTER-AIDED UNDERGROUND BLAST DESIGN SYSTEM
    FAVREAU, P
    ANDRIEUX, P
    CIM BULLETIN, 1993, 86 (967): : 62 - 68
  • [45] COMPUTER-AIDED 3-DIMENSIONAL RECONSTRUCTION SYSTEM FROM SERIAL SECTION IMAGES
    BABA, N
    BABA, M
    IMAMURA, M
    KOGA, M
    OSUMI, M
    KANAYA, K
    JOURNAL OF ELECTRON MICROSCOPY, 1987, 36 (05): : 336 - 336
  • [46] Computer-aided 3-dimensional reconstruction study of plexiform lesions in pulmonary hypertension
    Cool, CD
    Stewart, JS
    Werahera, P
    Miller, G
    Voelkel, N
    Tuder, R
    MODERN PATHOLOGY, 1998, 11 (01) : 4A - 4A
  • [47] COMPUTER-AIDED 3-DIMENSIONAL RECONSTRUCTIONS OF BIOLOGICAL OBJECTS USING SIMPLE FACILITIES
    SPACEK, J
    DOLEZAL, T
    HANUS, J
    HARTMANN, M
    FOLIA BIOLOGICA, 1989, 35 (05) : 329 - &
  • [48] The reproducibility of the virtual organ computer-aided analysis program for evaluating 3-dimensional power Doppler ultrasonography of diffuse thyroid disorders
    S. C. Chiou
    M. H. Hsieh
    H. Y. Chen
    J. D. Lin
    C. C. Chen
    W. H. Hsu
    L. B. Jeng
    C. T. Chang
    R. H. Chen
    T. Y. Wang
    W. L. Haung
    Journal of Endocrinological Investigation, 2009, 32 : 139 - 146
  • [49] The reproducibility of the virtual organ computer-aided analysis program for evaluating 3-dimensional power Doppler ultrasonography of diffuse thyroid disorders
    Chiou, S. -C.
    Hsieh, M. -H.
    Chen, H. -Y.
    Lin, J. -D.
    Chen, C. -C.
    Hsu, W. -H.
    Jeng, L. -B.
    Chang, C. -T.
    Chen, R. -H.
    Wang, T. -Y.
    Haung, W. -L.
    JOURNAL OF ENDOCRINOLOGICAL INVESTIGATION, 2009, 32 (02) : 139 - 146
  • [50] A nomogram of fetal lung volumes estimated by 3-dimensional ultrasonography using the rotational technique (virtual organ computer-aided analysis)
    Ruano, R
    Joubin, L
    Aubry, MC
    Thalabard, JC
    Dommergues, M
    Dumez, Y
    Benachi, A
    JOURNAL OF ULTRASOUND IN MEDICINE, 2006, 25 (06) : 701 - 709