Computer-aided diagnosis for 3-dimensional breast ultrasonography

被引:26
|
作者
Chen, DR
Chang, RF
Chen, WM
Moon, WK
机构
[1] China Med Coll & Hosp, Dept Gen Surg, Taichung, Taiwan
[2] Natl Chung Cheng Univ, Dept Comp Sci & Informat Engn, Chiayi, Taiwan
[3] Seoul Natl Univ Hosp, Dept Diagnost Radiol, Seoul 110744, South Korea
关键词
D O I
10.1001/archsurg.138.3.296
中图分类号
R61 [外科手术学];
学科分类号
摘要
Hypothesis: Using 3-dimensional (3-D) over 2-dimensional (2-D) ultrasonographic (US) images of the breast represents a potentially significant advantage for computer-aided diagnosis (CAD). Background: Although conventional 2-D US images of the breast are increasingly used in surgical, clinical practice, 3-D US imaging of the breast, a newly introduced technique, can offer more information than 2-D US images do. Design: This study deals with a I CAD method for use with the proposed 3-D US images of the breast and compares its performance with conventional 2-D US versions. Methods: The test databases included 3-D US images of 107 benign and 54 malignant breast tumors for a total of 161 US images. All solid nodules at US belong to categories above C3 (ie, probably benign). The 3-D US imaging was performed using a scanner (Voluson 530; kretz Technik, Zipf, Austria). New 3-D autocorrelation coefficients extended from the traditional 2-D autocorrelations were developed to extract the texture characteristics of the 3-D US images. The extracted texture features of the 3-D US images were used to classify the tumor as benign or malignant using the neural network. Results: At the receiver operating characteristic analysis, 3-D and 2-D autocorrelation calculating schemes yielded Az values (ie, area under the receiver operating characteristic curve) of 0.97 and 0.85 in distinguishing between benign and malignant lesions, respectively. Accuracy, sensitivity, specificity, positive predictive value, and negative predictive value are statistically significantly improved using 3-D instead of 2-D US images for CAD. Conclusions: The proposed system (for 3-D and 2-D CAD) is expected. to be a useful computer-aided diagnostic tool for classifying benign and malignant tumors on ultrasonograms and can provide a second reading to help reduce misdiagnosis. Findings from this study suggest that using 3-D over 2-D US images for CAD represents a potentially significant advantage.
引用
收藏
页码:296 / 302
页数:7
相关论文
共 50 条
  • [31] Advances in computer-aided diagnosis for breast cancer
    Hadjiiski, Lubomir
    Sahiner, Berkman
    Chan, Heang-Ping
    CURRENT OPINION IN OBSTETRICS & GYNECOLOGY, 2006, 18 (01) : 64 - 70
  • [32] Computer-aided diagnosis system of thyroid nodules ultrasonography Diagnostic performance difference between computer-aided diagnosis and 111 radiologists
    Li, Tingting
    Jiang, Zirui
    Lu, Man
    Zou, Shibin
    Wu, Minggang
    Wei, Ting
    Wang, Lu
    Li, Juan
    Hu, Ziyue
    Cheng, Xueqing
    Liao, Jifen
    MEDICINE, 2020, 99 (23)
  • [33] Computer-aided Diagnosis of Various Diseases Using Ultrasonography Images
    Mohit, Kumar
    Gupta, Rajeev
    Kumar, Basant
    CURRENT MEDICAL IMAGING, 2024, 20
  • [34] Computer-Aided tumor diagnosis in 3-D breast elastography
    Huang, Yao-Sian
    Takada, Etsuo
    Konno, Sachiyo
    Huang, Chiun-Shen
    Kuo, Ming-Hao
    Chang, Ruey-Feng
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2018, 153 : 201 - 209
  • [35] COMPUTER-AIDED 3-DIMENSIONAL RECONSTRUCTION AND MEASUREMENT OF THE ROUND WINDOW AND ITS MEMBRANE
    TAKAHASHI, H
    TAKAGI, A
    SANDO, I
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1989, 101 (05) : 517 - 521
  • [36] Computer-aided 3-dimensional reconstruction study of plexiform lesions in pulmonary hypertension
    Cool, CD
    Stewart, JS
    Werahera, P
    Miller, G
    Voelkel, N
    Tuder, R
    LABORATORY INVESTIGATION, 1998, 78 (01) : 4A - 4A
  • [37] 3-DIMENSIONAL COMPUTER-AIDED RECONSTRUCTION AND MEASUREMENT OF THE TEMPORAL BONE FOR SINGULAR NEURECTOMY
    TAKAHASHI, H
    SANDO, I
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 1992, 249 (02) : 74 - 78
  • [38] 3-DIMENSIONAL SURGICAL ANATOMY FOR STAPES SURGERY COMPUTER-AIDED RECONSTRUCTION AND MEASUREMENT
    TAKAHASHI, H
    SANDO, I
    LARYNGOSCOPE, 1992, 102 (10): : 1159 - 1164
  • [39] USE OF A COMPUTER-AIDED RECONSTRUCTION SYSTEM TO EXAMINE THE 3-DIMENSIONAL ARCHITECTURE OF CYANOBACTERIA
    NIERZWICKIBAUER, SA
    BALKWILL, DL
    STEVENS, SE
    JOURNAL OF ULTRASTRUCTURE RESEARCH, 1983, 84 (01): : 73 - 82
  • [40] COMPUTER-AIDED 3-DIMENSIONAL RECONSTRUCTION AND MEASUREMENT OF SEMICIRCULAR CANALS AND THEIR CRISTAE IN MAN
    TAKAGI, A
    SANDO, I
    TAKAHASHI, H
    ACTA OTO-LARYNGOLOGICA, 1989, 107 (5-6) : 362 - 365