Commercial Screen-Printed Electrodes Based on Carbon Nanomaterials for a Fast and Cost-Effective Voltammetric Determination of Paracetamol, Ibuprofen and Caffeine in Water Samples

被引:50
|
作者
Serrano, Nuria [1 ]
Castilla, Oscar [1 ]
Arino, Cristina [1 ,2 ]
Silvia Diaz-Cruz, M. [3 ]
Manuel Diaz-Cruz, Jose [1 ]
机构
[1] Univ Barcelona, Dept Chem Engn & Analyt Chem, Marti i Franques 1-11, E-08028 Barcelona, Spain
[2] Univ Barcelona, Inst Recerca Aigua IdRA, E-08028 Barcelona, Spain
[3] CSIC, Spanish Council Sci Res, Inst Environm Assessment & Water Res, Dept Environm Chem,IDAEA, Jordi Girona 18-26, Barcelona 08034, Spain
关键词
screen-printed electrodes; carbon nanomaterials; voltammetry; ibuprofen; paracetamol; caffeine; TANDEM MASS-SPECTROMETRY; LIQUID-CHROMATOGRAPHY; PHARMACEUTICALS; PASTE;
D O I
10.3390/s19184039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Carbon screen-printed electrode (SPCE), multi-walled carbon nanotubes modified screen-printed electrode (SPCNTE), carbon nanofibers modified screen-printed electrode (SPCNFE), and graphene modified screen-printed electrode (SPGPHE) were in a pioneer way tested as sensors for the simultaneous determination of the two most consumed pain-killers, paracetamol (PA) and ibuprofen (IB), and the stimulant caffeine (CF) in water by differential pulse voltammetry (DPV). Their analytical performances were compared, and the resulting sensitivities (2.50, 0.074, and 0.24 mu A V mg(-1) L for PA, IB, and CF, respectively), detection limits (0.03, 0.6, and 0.05 mg L-1 for PA, IB, and CF, respectively) and quantification limits (0.09, 2.2, and 0.2 mg L-1 for PA, IB, and CF, respectively) suggested that the SPCNFE was the most suitable carbon-based electrode for the voltammetric determination of the selected analytes in water at trace levels. The methodology was validated using both spiked tap water and hospital wastewater samples. The results were compared to those achieved by liquid chromatography-tandem mass spectrometry (LC-MS/MS), the technique of choice for the determination of the target analytes.
引用
收藏
页数:16
相关论文
共 38 条
  • [21] Electrochemical study and flow injection analysis of paracetamol in pharmaceutical formulations based on screen-printed electrodes and carbon nanotubes
    Fanjul-Bolado, Pablo
    Jose Lamas-Ardisana, Pedro
    Hernandez-Santos, David
    Costa-Garcia, Agustin
    ANALYTICA CHIMICA ACTA, 2009, 638 (02) : 133 - 138
  • [22] Adsorptive stripping voltammetric method for the determination of caffeine at integrated three-electrode screen-printed sensor with carbon/carbon nanofibers working electrode
    Tyszczuk-Rotko, Katarzyna
    Pietrzak, Karolina
    Sasal, Agnieszka
    ADSORPTION-JOURNAL OF THE INTERNATIONAL ADSORPTION SOCIETY, 2019, 25 (04): : 913 - 921
  • [23] Portable and Cost-Effective Detection of Perfluorooctanesulfonate in Water Using a Screen-Printed Electrode Modified with Molecularly Imprinted Polymer
    Wang, Shangqing
    Ma, Lulu
    Feng, Xiaonan
    Zhang, Kun
    Chen, Zheqian
    Hu, Min
    Zheng, Guomao
    Zheng, Yan
    Zhang, Bintian
    ACS ES&T WATER, 2025, 5 (03): : 1261 - 1269
  • [24] Low-cost screen-printed electrodes based on electrochemically reduced graphene oxide-carbon black nanocomposites for dopamine, epinephrine and paracetamol detection
    Ibanez-Redin, G.
    Wilson, D.
    Goncalves, D.
    Oliveira, O. N., Jr.
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2018, 515 : 101 - 108
  • [25] Uric Acid Determination by Adsorptive Stripping Voltammetry on Multiwall Carbon Nanotubes Based Screen-Printed Electrodes
    Fanjul-Bolado, Pablo
    Hernandez Santos, David
    Macho Montoya, Virgilio
    Costa-Garcia, Agustin
    ELECTROANALYSIS, 2015, 27 (05) : 1276 - 1281
  • [26] Effective electrochemical sensor based on screen-printed electrodes modified with a carbon black-Au nanoparticles composite
    Arduini, F.
    Zanardi, C.
    Cinti, S.
    Terzi, F.
    Moscone, D.
    Palleschi, G.
    Seeber, R.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 212 : 536 - 543
  • [27] Indirect determination of Escherichia coli based on β-D-glucuronidase activity and the voltammetric oxidation of phenolphthalein at graphite screen-printed electrodes
    Poulouxi, Stela
    Prodromidis, Mamas I.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 879
  • [28] A customizable cost-effective design for printed circuit board-based nanolayered gold screen-printed electrode: From fabrication to bioapplications
    Ghorbanzadeh, Sadegh
    Naghib, Seyed Morteza
    Sadr, Ali
    Molaabasi, Fatemeh
    Zhang, Wei
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [29] Square wave voltammetric determination of paracetamol at chitosan modified carbon paste electrode: Application in natural water samples, commercial tablets and human urines
    El Bouabi, Y.
    Farahi, A.
    Labjar, N.
    El Hajjaji, S.
    Bakasse, M.
    El Mhammedi, M. A.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 58 : 70 - 77
  • [30] A new voltammetric method for the simultaneous determination of the antioxidants TBHQ and BHA in biodiesel using multi-walled carbon nanotube screen-printed electrodes
    Caramit, Ricardo Pini
    de Freitas Andrade, Adriana Garabini
    Gomes de Souza, Joao Batista
    de Araujo, Tatiane Alfonso
    Viana, Luiz Henrique
    Goncalves Trindade, Magno Aparecido
    Ferreira, Valdir Souza
    FUEL, 2013, 105 : 306 - 313