Debris production in bovine bone during implant site preparation. A comparative in vitro study: ultrasonic and drilling procedures

被引:0
作者
Rebaudi, A.
Rebaudi, F.
Tinarelli, V
Barberis, F. [1 ]
Giacomello, M. S. [2 ]
Lo Russo, F. [3 ,4 ]
Lucchina, A. Greco [5 ]
Sammartino, P.
Marenzi, G. [6 ]
机构
[1] Univ Genoa, Dept Civil Environm & Chem Engn, Genoa, Italy
[2] Univ Milano Bicocca, Dept Med & Surg, Milan, Italy
[3] Univ G dAnnunzio, Dept Innovat Technol Med & Dent, Chieti, Italy
[4] Univ G dAnnunzio, CAST, BioClinLab, Chieti, Italy
[5] St Camillus Int Univ Hlth Sci, Rome, Italy
[6] Univ Naples Federico II, Dept Neurosci Reprod & Odontostomatol Sci, Via Pansini 5, I-80131 Naples, Italy
关键词
ultrasonic implant site preparation; surgical drill; implant preparation; bone damage; osseointegration; PRIMARY STABILITY; PIEZOELECTRIC SURGERY; TITANIUM IMPLANTS; DENTAL IMPLANTS; HEAT-PRODUCTION; OSSEOINTEGRATION; INSERTION; VIVO; CLASSIFICATION; PIEZOSURGERY;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to compare the size and shape of bone fragments produced by the ultrasonic and drilling procedures in implant site preparation. Six pieces of rib selected as experimental animal model of 15 cm in length and at least 13 mm of thickness were used. The samples were treated and divided into 2 groups as follows: group A (GA) ultrasonic implant site preparation technique; group B (GB) traditional surgical drill technique. Ultrasonic implant site preparation (GA) was carried out using a sequence of progressive diameter (1.00 mm, 2.00 mm and 3.00 mm) conical inserts at a depth of 10 mm. Standard drill implant site procedure (GB) was carried out with a sequence of 1.00 mm, 2.00 mm, and 3.00 mm cylindrical twist drills, for preparing an implant site at a depth of 10 mm. From each group bone fragments (0.1 gr) were collected from both cortical and cancellous bone preparation and their dimensions were evaluated by optic microscope analysis. The bone debris dimensions procured by cortical bone of Group A and Group B were, respectively, 0.14x0.16 mm (+/- 0.13) and 1.15 x0.92 mm (+/- 0.68). The bone debris dimensions procured by cancellous bone of Group A and Group B were, respectively, 0.15x0.10 mm (+/- 0.10) and 1.98x1.27 mm (+/- 0.94). Ultrasonic implant site preparation technique was able to micronize bone and to remove all debris with cooling system. Surgical drills tend to fracture bone, creating a weaker structure and fragments of larger size, which remain in considerable quantity over bone walls during site preparation. Within the limits of the present study, the ultrasonic implant preparation was able to produce reduced bone sediments and a clear bed implant favoring osseointegration.
引用
收藏
页码:323 / 329
页数:7
相关论文
共 37 条
[31]   Effect of the Combination of Low-Speed Drilling and Cooled Irrigation Fluid on Intraosseous Heat Generation During Guided Surgical Implant Site Preparation: An In Vitro Study [J].
Barrak, Ibrahim ;
Joo-Fancsaly, Arpad ;
Varga, Endre ;
Boa, Kristof ;
Piffko, Jozsef .
IMPLANT DENTISTRY, 2017, 26 (04) :541-546
[32]   Influence of bone density, drill diameter, drilling speed, and irrigation on temperature changes during implant osteotomies: an in vitro study [J].
Salomo-Coll, Oscar ;
Auriol-Muerza, Beatriz ;
Lozano-Carrascal, Naroa ;
Hernandez-Alfaro, Federico ;
Wang, Hom-Lay ;
Gargallo-Albiol, Jordi .
CLINICAL ORAL INVESTIGATIONS, 2021, 25 (03) :1047-1053
[33]   Influence of Bone Quality, Drilling Protocol, Implant Diameter/Length on Primary Stability: An In Vitro Comparative Study on Insertion Torque and Resonance Frequency Analysis [J].
Farronato, Davide ;
Manfredini, Mattia ;
Stocchero, Michele ;
Caccia, Mattia ;
Azzi, Lorenzo ;
Farronato, Marco .
JOURNAL OF ORAL IMPLANTOLOGY, 2020, 46 (03) :182-189
[34]   The Assessment of the Maximum Heat Production and Cooling Effectiveness of Three Different Drill Types (Conical vs. Cylindrical vs. Horizontal) during Implant Bed Preparation-An In Vitro Study [J].
Ihde, Stefan ;
Dalewski, Bartosz ;
Palka, Lukasz .
APPLIED SCIENCES-BASEL, 2021, 11 (21)
[35]   A Comparative In Vitro Study on Heat Generation with Static Guided and Conventional Implant Bed Preparation Using Stainless Steel Twist Drills and a Standardized Bovine Model [J].
Tur, Dino ;
Tian, Zhiwei ;
Giannis, Katharina ;
Unger, Ewald ;
Mittlboeck, Martina ;
Rausch-Fan, Xiaohui ;
Strbac, Georg D. .
MATERIALS, 2025, 18 (06)
[36]   Comparison of heat production and bone architecture changes in the implant site preparation with compressive osteotomes, osseodensification technique, piezoelectric devices, and standard drills: an ex vivo study on porcine ribs [J].
Nishith Bhargava ;
Vittoria Perrotti ;
Vito Carlo Alberto Caponio ;
Victor Haruo Matsubara ;
Diana Patalwala ;
Alessandro Quaranta .
Odontology, 2023, 111 :142-153
[37]   Thermal changes during implant site preparation with a digital surgical guide and slot design drill: an ex vivo study using a bovine rib model [J].
Choi, Yoon-Sil ;
Oh, Jae-Woon ;
Lee, Young ;
Lee, Dong-Woon .
JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2022, 52 (05) :411-421