Debris production in bovine bone during implant site preparation. A comparative in vitro study: ultrasonic and drilling procedures

被引:0
作者
Rebaudi, A.
Rebaudi, F.
Tinarelli, V
Barberis, F. [1 ]
Giacomello, M. S. [2 ]
Lo Russo, F. [3 ,4 ]
Lucchina, A. Greco [5 ]
Sammartino, P.
Marenzi, G. [6 ]
机构
[1] Univ Genoa, Dept Civil Environm & Chem Engn, Genoa, Italy
[2] Univ Milano Bicocca, Dept Med & Surg, Milan, Italy
[3] Univ G dAnnunzio, Dept Innovat Technol Med & Dent, Chieti, Italy
[4] Univ G dAnnunzio, CAST, BioClinLab, Chieti, Italy
[5] St Camillus Int Univ Hlth Sci, Rome, Italy
[6] Univ Naples Federico II, Dept Neurosci Reprod & Odontostomatol Sci, Via Pansini 5, I-80131 Naples, Italy
关键词
ultrasonic implant site preparation; surgical drill; implant preparation; bone damage; osseointegration; PRIMARY STABILITY; PIEZOELECTRIC SURGERY; TITANIUM IMPLANTS; DENTAL IMPLANTS; HEAT-PRODUCTION; OSSEOINTEGRATION; INSERTION; VIVO; CLASSIFICATION; PIEZOSURGERY;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to compare the size and shape of bone fragments produced by the ultrasonic and drilling procedures in implant site preparation. Six pieces of rib selected as experimental animal model of 15 cm in length and at least 13 mm of thickness were used. The samples were treated and divided into 2 groups as follows: group A (GA) ultrasonic implant site preparation technique; group B (GB) traditional surgical drill technique. Ultrasonic implant site preparation (GA) was carried out using a sequence of progressive diameter (1.00 mm, 2.00 mm and 3.00 mm) conical inserts at a depth of 10 mm. Standard drill implant site procedure (GB) was carried out with a sequence of 1.00 mm, 2.00 mm, and 3.00 mm cylindrical twist drills, for preparing an implant site at a depth of 10 mm. From each group bone fragments (0.1 gr) were collected from both cortical and cancellous bone preparation and their dimensions were evaluated by optic microscope analysis. The bone debris dimensions procured by cortical bone of Group A and Group B were, respectively, 0.14x0.16 mm (+/- 0.13) and 1.15 x0.92 mm (+/- 0.68). The bone debris dimensions procured by cancellous bone of Group A and Group B were, respectively, 0.15x0.10 mm (+/- 0.10) and 1.98x1.27 mm (+/- 0.94). Ultrasonic implant site preparation technique was able to micronize bone and to remove all debris with cooling system. Surgical drills tend to fracture bone, creating a weaker structure and fragments of larger size, which remain in considerable quantity over bone walls during site preparation. Within the limits of the present study, the ultrasonic implant preparation was able to produce reduced bone sediments and a clear bed implant favoring osseointegration.
引用
收藏
页码:323 / 329
页数:7
相关论文
共 37 条
[21]   The impact of surgical guide design and bone quality on heat generation during pilot implant site preparation: an in vitro study [J].
Eman Abuhajar ;
Nesreen A. Salim ;
Malik Sallam ;
Fadi Jarab ;
Julian D. Satterthwaite .
BMC Oral Health, 23
[22]   An in vitro study of temperature changes in type 4 bone during implant placement: bone condensing versus bone drilling [J].
Misic, Tijana ;
Markovic, Aleksa ;
Todorovic, Aleksandar ;
Colic, Snjezana ;
Miodrag, Scepanovic ;
Milicic, Biljana .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2011, 112 (01) :28-33
[23]   A site-specific intraoperative measurement of bone-to-implant contact during implant insertion: A study on bovine ribs using a computerized implant motor [J].
Lezzi, Giovanna ;
Filippone, Antonella ;
Di Stefano, Danilo ;
Arosio, Paolo ;
Piattelli, Adriano ;
Scarano, Antonio ;
Perrotti, Vittoria .
JOURNAL OF DENTAL SCIENCES, 2015, 10 (01) :21-27
[24]   The Influence of Various Preparation Parameters on the Histological Image of Bone Tissue during Implant Bed Preparation-An In Vitro Study [J].
Kosior, Piotr ;
Kuropka, Piotr ;
Janeczek, Maciej ;
Mikulewicz, Marcin ;
Zakrzewski, Wojciech ;
Dobrzynski, Maciej .
APPLIED SCIENCES-BASEL, 2021, 11 (04) :1-11
[25]   Heat Generation During Initial Osteotomy for Implant Site Preparation: An In Vitro Measurement Study [J].
Luca Aquilanti ;
Luca Antognoli ;
Giorgio Rappelli ;
Roberto Di Felice ;
Lorenzo Scalise .
Journal of Maxillofacial and Oral Surgery, 2023, 22 :313-320
[26]   Heat Generation During Initial Osteotomy for Implant Site Preparation: An In Vitro Measurement Study [J].
Aquilanti, Luca ;
Antognoli, Luca ;
Rappelli, Giorgio ;
Di Felice, Roberto ;
Scalise, Lorenzo .
JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2023, 22 (02) :313-320
[27]   Temperatures generated during implant site preparation with conventional drilling versus single-drill method: an ex-vivo human mandible study [J].
Bacci, Christian ;
Lucchiari, Nicola ;
Frigo, Anna C. ;
Stecco, Carla ;
Zanette, Gastone ;
Dotto, Virginia ;
Sivolella, Stefano .
MINERVA STOMATOLOGICA, 2019, 68 (06) :277-284
[28]   Temperature changes in bovine mandibular bone during implant site preparation: An assessment using infra-red thermography [J].
Benington, IC ;
Biagioni, PA ;
Crossey, PJ ;
Hussey, DL ;
Sheridan, S ;
Lamey, PJ .
JOURNAL OF DENTISTRY, 1996, 24 (04) :263-267
[29]   IMPLANT SITE PREPARATION USING ULTRASONIC TECHNIQUE VS. CONVENTIONAL DRILLING: THREE-YEAR FOLLOW-UP OF A SPLIT-MOUTH STUDY [J].
Mozzati, M. ;
Gallesio, G. ;
Pol, R. ;
Cipollina, A. ;
Giacalone, A. ;
Mucciacito, N. ;
Galli, M. ;
Karanxha, L. ;
Lucchina, A. Greco ;
Del Fabbro, M. .
JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2019, 33 (06) :49-58
[30]   Effect of Guiding Sleeve Design on Intraosseous Heat Generation During Implant Site Preparation (In Vitro Study) [J].
Ashry, Amal ;
Elattar, Mohamed Sherine ;
Elsamni, Osama Ahmed ;
Soliman, Ingy Saied .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (02) :147-154