Debris production in bovine bone during implant site preparation. A comparative in vitro study: ultrasonic and drilling procedures

被引:0
|
作者
Rebaudi, A.
Rebaudi, F.
Tinarelli, V
Barberis, F. [1 ]
Giacomello, M. S. [2 ]
Lo Russo, F. [3 ,4 ]
Lucchina, A. Greco [5 ]
Sammartino, P.
Marenzi, G. [6 ]
机构
[1] Univ Genoa, Dept Civil Environm & Chem Engn, Genoa, Italy
[2] Univ Milano Bicocca, Dept Med & Surg, Milan, Italy
[3] Univ G dAnnunzio, Dept Innovat Technol Med & Dent, Chieti, Italy
[4] Univ G dAnnunzio, CAST, BioClinLab, Chieti, Italy
[5] St Camillus Int Univ Hlth Sci, Rome, Italy
[6] Univ Naples Federico II, Dept Neurosci Reprod & Odontostomatol Sci, Via Pansini 5, I-80131 Naples, Italy
来源
JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS | 2021年 / 35卷 / 02期
关键词
ultrasonic implant site preparation; surgical drill; implant preparation; bone damage; osseointegration; PRIMARY STABILITY; PIEZOELECTRIC SURGERY; TITANIUM IMPLANTS; DENTAL IMPLANTS; HEAT-PRODUCTION; OSSEOINTEGRATION; INSERTION; VIVO; CLASSIFICATION; PIEZOSURGERY;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to compare the size and shape of bone fragments produced by the ultrasonic and drilling procedures in implant site preparation. Six pieces of rib selected as experimental animal model of 15 cm in length and at least 13 mm of thickness were used. The samples were treated and divided into 2 groups as follows: group A (GA) ultrasonic implant site preparation technique; group B (GB) traditional surgical drill technique. Ultrasonic implant site preparation (GA) was carried out using a sequence of progressive diameter (1.00 mm, 2.00 mm and 3.00 mm) conical inserts at a depth of 10 mm. Standard drill implant site procedure (GB) was carried out with a sequence of 1.00 mm, 2.00 mm, and 3.00 mm cylindrical twist drills, for preparing an implant site at a depth of 10 mm. From each group bone fragments (0.1 gr) were collected from both cortical and cancellous bone preparation and their dimensions were evaluated by optic microscope analysis. The bone debris dimensions procured by cortical bone of Group A and Group B were, respectively, 0.14x0.16 mm (+/- 0.13) and 1.15 x0.92 mm (+/- 0.68). The bone debris dimensions procured by cancellous bone of Group A and Group B were, respectively, 0.15x0.10 mm (+/- 0.10) and 1.98x1.27 mm (+/- 0.94). Ultrasonic implant site preparation technique was able to micronize bone and to remove all debris with cooling system. Surgical drills tend to fracture bone, creating a weaker structure and fragments of larger size, which remain in considerable quantity over bone walls during site preparation. Within the limits of the present study, the ultrasonic implant preparation was able to produce reduced bone sediments and a clear bed implant favoring osseointegration.
引用
收藏
页码:323 / 329
页数:7
相关论文
共 49 条
  • [1] Thermal changes and drill wear in bovine bone during implant site preparation. A comparative in vitro study: twisted stainless steel and ceramic drills
    Oliveira, Natalia
    Alaejos-Algarra, Fernando
    Mareque-Bueno, Javier
    Ferres-Padro, Eduard
    Hernandez-Alfaro, Federico
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (08) : 963 - 969
  • [2] Comparative Analysis of Bone Tissue Temperature during Implant Preparation with Variable Drilling Parameters: In Vitro Study
    Kosior, Piotr
    Pelc, Anna
    Mikulewicz, Marcin
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [3] Ultrasonic implant site preparation vs. conventional drilling: in-vitro evaluation of implant site diameter
    Lahoud, Pierre
    Nasr, Joseph Abi
    Menhall, Abdallah
    Rebaudi, Alberto
    Makary, Christian
    CHIRURGIA-ITALY, 2023, 37 (04): : 224 - 231
  • [4] Slow drilling speeds for single-drill implant bed preparation. Experimental in vitro study
    Delgado-Ruiz, R. A.
    Velasco Ortega, E.
    Romanos, G. E.
    Gerhke, S.
    Newen, I.
    Calvo-Guirado, J. L.
    CLINICAL ORAL INVESTIGATIONS, 2018, 22 (01) : 349 - 359
  • [5] Slow drilling speeds for single-drill implant bed preparation. Experimental in vitro study
    R. A. Delgado-Ruiz
    E. Velasco Ortega
    G. E. Romanos
    S. Gerhke
    I. Newen
    J. L. Calvo-Guirado
    Clinical Oral Investigations, 2018, 22 : 349 - 359
  • [6] In Vitro Study on Bone Heating during Drilling of the Implant Site: Material, Design and Wear of the Surgical Drill
    Carlos Bernabeu-Mira, Juan
    Pellicer-Chover, Hilario
    Penarrocha-Diago, Miguel
    Penarrocha-Oltra, David
    MATERIALS, 2020, 13 (08)
  • [7] TEMPERATURE-CHANGES IN BOVINE MANDIBULAR BONE DURING IMPLANT SITE PREPARATION
    CROSSEY, P
    BIAGIONI, PA
    LAMEY, PJ
    SHERIDAN, S
    BENINGTON, IC
    JOURNAL OF DENTAL RESEARCH, 1994, 73 : 398 - 398
  • [8] Heat generation during implant site preparation: An in vitro study
    Cordioli, G
    Majzoub, Z
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1997, 12 (02) : 186 - 193
  • [9] Thermal effects of various drill materials during implant site preparation-Ceramic vs. stainless steel drills: A comparative in vitro study in a standardised bovine bone model
    Tur, Dino
    Giannis, Katharina
    Unger, Ewald
    Mittlbock, Martina
    Rausch-Fan, Xiaohui
    Strbac, Georg D.
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (02) : 154 - 166
  • [10] An in-vitro study of temperature rise during rotary ultrasonic bone drilling of human bone
    Singh, Ravinder Pal
    Pandey, Pulak Mohan
    Mridha, Asit Ranjan
    MEDICAL ENGINEERING & PHYSICS, 2020, 79 : 33 - 43