Validation of the AnyBody full body musculoskeletal model in computing lumbar spine loads at L4L5 level

被引:84
作者
Bassani, Tito [1 ]
Stucovitz, Elena [1 ]
Qian, Zhihui [2 ]
Briguglio, Matteo [1 ]
Galbusera, Fabio [1 ]
机构
[1] IRCCS Ist Ortoped Galeazzi, Milan, Italy
[2] Jilin Univ, Key Lab Bion Engn, Changchun, Peoples R China
关键词
Musculoskeletal modeling; Spine biomechanics; Motion capture; AnyBody; TRUNK MUSCLE FORCES; IN-VIVO; INTRADISCAL PRESSURE; INTERNAL LOADS; BIOMECHANICS; STABILITY; SYSTEM;
D O I
10.1016/j.jbiomech.2017.04.025
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In the panorama of available musculoskeletal modeling software, AnyBody software is a commercial tool that provides a full body musculoskeletal model which is increasingly exploited by numerous researchers worldwide. In this regard, model validation becomes essential to guarantee the suitability of the model in representing the simulated system. When focusing on lumbar spine, the previous works aimed at validating the AnyBody model in computing the intervertebral loads held several limitations, and a comprehensive validation is to be considered as lacking. The present study was aimed at extensively validating the suitability of the AnyBody model in computing lumbar spine loads at L4L5 level. The intersegmental loads were calculated during twelve specific exercise tasks designed to accurately replicate the conditions during which Wilke et al. (2001) measured in vivo the L4L5 intradiscal pressure. Motion capture data of one volunteer subject were acquired during the execution of the tasks and then imported into AnyBody to set model kinematics. Two different approaches in computing intradiscal pressure from the intersegmental load were evaluated. Lumbopelvic rhythm was compared with reference in vivo measurements to assess the accuracy of the lumbopelvic kinematics. Positive agreement was confirmed between the calculated pressures and the in vivo measurements, thus demonstrating the suitability of the AnyBody model. Specific caution needs to be taken only when considering postures characterized by large lateral displacements. Minor discrepancy was found assessing lumbopelvic rhythm. The present findings promote the AnyBody model as an appropriate tool to non invasively evaluate the lumbar loads at I4L5 in physiological activities. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:89 / 96
页数:8
相关论文
共 35 条
[21]   Computational biomechanical modeling of scoliotic spine: Challenges and opportunities [J].
Jalalian A. ;
Gibson I. ;
Tay E.H. .
Spine Deformity, 2013, 1 (6) :401-411
[22]   On validation of multibody musculoskeletal models [J].
Lund, Morten Enemark ;
de Zee, Mark ;
Andersen, Michael Skipper ;
Rasmussen, John .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2012, 226 (H2) :82-94
[23]   High pressures and asymmetrical stresses in the scoliotic disc in the absence of muscle loading [J].
Meir, Adam R. ;
Fairbank, Jeremy C. T. ;
Jones, Deborah A. ;
McNally, Donal S. ;
Urban, Jill P. G. .
SCOLIOSIS AND SPINAL DISORDERS, 2007, 2
[24]   Incorporating Six Degree-of-Freedom Intervertebral Joint Stiffness in a Lumbar Spine Musculoskeletal Model-Method and Performance in Flexed Postures [J].
Meng, Xiangjie ;
Bruno, Alexander G. ;
Cheng, Bo ;
Wang, Wenjun ;
Bouxsein, Mary L. ;
Anderson, Dennis E. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2015, 137 (10)
[25]  
NACHEMSON A, 1960, Acta Orthop Scand Suppl, V43, P1
[26]   An investigation of jogging biomechanics using the full-body lumbar spine model: Model development and validation [J].
Raabe, Margaret E. ;
Chaudhari, Ajit M. W. .
JOURNAL OF BIOMECHANICS, 2016, 49 (07) :1238-1243
[27]   Comparative evaluation of six quantitative lifting tools to estimate spine loads during static activities [J].
Rajaee, Mohammad Ali ;
Arjmand, Navid ;
Shirazi-Adl, Aboulfazl ;
Plamondon, Andre ;
Schmidt, Hendrik .
APPLIED ERGONOMICS, 2015, 48 :22-32
[28]   Muscle recruitment by the min/max criterion - a comparative numerical study [J].
Rasmussen, J ;
Damsgaard, M ;
Voigt, M .
JOURNAL OF BIOMECHANICS, 2001, 34 (03) :409-415
[29]  
Rasmussen J., 2009, 22 C INT SOC BIOM
[30]   Telemeterized load measurement using instrumented spinal internal fixators in a patient with degenerative instability [J].
Rohlmann, A ;
Bergmann, G ;
Graichen, F ;
Mayer, HM .
SPINE, 1995, 20 (24) :2683-2689