Effect of coronal fracture angle on the stability of screw fixation in medial malleolar fractures: A finite element analysis

被引:5
作者
Emre, Tuluhan Yunus [1 ]
Celik, Huseyin Kursat [2 ]
Arik, Hasan O. [3 ]
Rennie, Allan E. W. [4 ]
Kose, Ozkan [3 ]
机构
[1] Biruni Univ, Med Fac, Orthopaed & Traumatol Dept, Istanbul, Turkey
[2] Akdeniz Univ, Dept Agr Machinery & Technol Engn, TR-07070 Antalya, Turkey
[3] Antalya Training & Res Hosp, Orthopaed & Traumatol Dept, Antalya, Turkey
[4] Univ Lancaster, Engn Dept, Lancaster, England
关键词
Medial malleolus fracture; fracture angle; fixation; finite element analysis; biomechanics; VERTICAL SHEAR FRACTURES; HUMAN CORTICAL BONE; ARTICULAR-CARTILAGE; COMPUTED-TOMOGRAPHY; INTERNAL-FIXATION; ANKLE FRACTURES; TRABECULAR BONE; THICKNESS; CONTACT; PLATE;
D O I
10.1177/09544119221089723
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Malleolar screw fixation is the most widely used treatment method for medial malleolar (MM) fractures. Here, although buttress plate fixation is advocated for vertical MM fractures, the angular discrimination between oblique and vertical MM fractures is still not fully understood. The purpose of this study is to test the adequacy of screw fixation in MM fractures with different angles and determination of a 'critical fracture angle' to guide surgeons in the decision-making for screw fixation for MM fractures by utilizing an advanced engineering simulation approach. In addition to loading of the healthy tibia structure, various cases of the MM fracture double screw fixation (14 simulation scenarios in total with fracture angles between 30 degrees and 90 degrees, in 5 degrees increments) were considered in this research and their static loading conditions just after fixation operation were simulated through nonlinear (geometric and contact nonlinearity) finite element analysis (FEA). Patient-specific computed tomography scan data, parametric three-dimensional solid modelling and finite element method (FEM) based engineering codes were employed in order to simulate the fixation scenarios. Visual and numerical outputs for the deformation and stress distributions, separation and sliding behaviours of the MM fracture fragments of various screw fixations were clearly exhibited through FEA results. Minimum and maximum separation distances (gap) of 3.75 and 150.34 mu m between fracture fragments at fracture angles of 30 degrees and 90 degrees were calculated respectively against minimum and maximum sliding distances of 25.87 and 41.37 mu m between fracture fragments at fracture angles of 90 degrees and 35 degrees, respectively. The FEA results revealed that while the separation distance was increasing, the sliding distance was decreasing and there were no distinct differences in sliding distances in the scenarios from fracture angles of 30 degrees-90 degrees. The limitations and errors in a FEA study are inevitable, however, it was interpreted that the FEA scenarios were setup in this study by utilizing acceptable assumptions providing logical outputs under pre-defined boundary conditions. Finally, the fracture healing threshold for separation and/or sliding distance between fracture fragments was assigned as 100 mu m by referring to previous literature and it was concluded that the screws fixed perpendicular to the fracture in a MM fracture with more than 70 degrees angle with the tibial plafond results in a significant articular separation ( > 100 mu m) during single-leg stand. Below this critical angle of 70 degrees, two screws provide sufficient fixation. [GRAPHICS] .
引用
收藏
页码:825 / 840
页数:16
相关论文
共 50 条
[41]   Biomechanical analysis of screw configurations on plate fixation in humeral shaft fracture: A Finite element analysis [J].
Naknual, Nutnicha ;
Kwanyuang, Atichart .
13TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2021), 2018,
[42]   Finite element analysis of fixation stability according to reduction position for internal fixation of intertrochanteric fractures [J].
Kim, Cheol-Jeong ;
Lee, Jung Sub ;
Goh, Tae Sik ;
Shin, Won Chul ;
Lee, Chiseung .
SCIENTIFIC REPORTS, 2024, 14 (01)
[43]   New fixation method for Pauwels type III femoral neck fracture: a finite element analysis of sliding hip screw, L-shaped, and L-shaped with medial plate [J].
Freitas, Anderson ;
Bontempo, Ricardo Lourenco ;
Ramos Azevedo, Frank Anderson ;
Battaglion, Leonardo Rigobello ;
Giordano, Marcos Noberto ;
Barin, Fabricio Reichert ;
Giordano, Vincenzo .
EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2021, 31 (06) :1069-1075
[44]   New fixation method for Pauwels type III femoral neck fracture: a finite element analysis of sliding hip screw, L-shaped, and L-shaped with medial plate [J].
Anderson Freitas ;
Ricardo Lourenço Bontempo ;
Frank Anderson Ramos Azevedo ;
Leonardo Rigobello Battaglion ;
Marcos Noberto Giordano ;
Fabrício Reichert Barin ;
Vincenzo Giordano .
European Journal of Orthopaedic Surgery & Traumatology, 2021, 31 :1069-1075
[45]   The Stability of Hydroxyapatite/Poly-L-Lactide Fixation for Unilateral Angle Fracture of the Mandible Assessed Using a Finite Element Analysis Model [J].
Park, Byungho ;
Jung, Bryan Taekyung ;
Kim, Won Hyeon ;
Lee, Jong-Ho ;
Kim, Bongju ;
Lee, Jee-Ho .
MATERIALS, 2020, 13 (01)
[46]   Finite Element Analysis of Insertion Angle of Absorbable Screws for the Fixation of Radial Head Fractures [J].
Xu, Guang-ming ;
Liang, Zi-yang ;
Li, Wei ;
Yang, Zheng-zhong ;
Chen, Zhi-bin ;
Zhang, Jie .
ORTHOPAEDIC SURGERY, 2020, 12 (06) :1710-1717
[47]   Comparison of four different screw configurations for the fixation of Fulkerson osteotomy: a finite element analysis [J].
Aykanat, Faruk ;
Kose, Ozkan ;
Guneri, Bulent ;
Celik, H. Kursat ;
Cakar, Albert ;
Tasatan, Ersin ;
Ulmeanu, Mihaela-Elena .
JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2023, 24 (01)
[48]   Comparison of volar versus dorsal screw fixation for scaphoid waist fractures: A finite element analysis [J].
Acar, Baver ;
Kose, Ozkan ;
Kati, Yusuf Alper ;
Egerci, Omer Faruk ;
Turan, Adil ;
Yuksel, Halil Yalcin .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2018, 104 (07) :1107-1113
[49]   Finite element analysis of spiral plate and Herbert screw fixation for treatment of midshaft clavicle fractures [J].
Zhang, Xiaojuan ;
Cheng, Xiaodong ;
Yin, Bing ;
Wang, Jianzhao ;
Li, Sheng ;
Liu, Guobin ;
Hu, Zusheng ;
Wu, Weiwei ;
Zhang, Yingze .
MEDICINE, 2019, 98 (34)
[50]   Effect of Fracture Gap on Stability of Compression Plate Fixation: A Finite Element Study [J].
Oh, Jong-Keon ;
Sahu, Dipit ;
Ahn, Yoon-Ho ;
Lee, Sung-Jae ;
Tsutsumi, Sadami ;
Hwang, Jin-Ho ;
Jung, Duk-Young ;
Perren, Stephan M. ;
Oh, Chang-Wug .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2010, 28 (04) :462-467