Device-based impedance measurement is a useful and accurate tool for direct assessment of intrathoracic fluid accumulation in heart failure

被引:16
作者
Becher, Jan [1 ]
Kaufmann, Susann G. [1 ]
Paule, Stefan [2 ]
Fahn, Bernhard [2 ]
Skerl, Olaf [2 ]
Bauer, Wolfgang R. [1 ]
Ertl, Georg [1 ]
Maier, Sebastian K. G. [1 ]
机构
[1] Univ Klinikum, Med Klin & Poliklin 1, D-97080 Wurzburg, Germany
[2] BIOTRONIK GmbH & Co KG, Erlangen, Germany
来源
EUROPACE | 2010年 / 12卷 / 05期
关键词
Impedance; Devices; Telemedicine; Heart failure; Patient management; IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR; TRANSTHORACIC ELECTRICAL-IMPEDANCE; CARDIAC-RESYNCHRONIZATION THERAPY; RATE-VARIABILITY; PULMONARY-EDEMA; DETERIORATION; THERMODILUTION; FEASIBILITY; CONGESTION; PRESSURE;
D O I
10.1093/europace/eup413
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Heart failure patients are often equipped with implanted devices and are frequently hospitalized due to volume overload. Reliable prediction of imminent fluid congestion has the potential to provide early detection of cardiac decompensation and therefore might be capable of enhancing therapy management. We investigated whether implant-based impedance (Z) measurement is closely correlated with directly assessed extravascular lung water and might thus be useful for patient monitoring. In sheep, pulmonary fluid congestion was induced. Continuous haemodynamic monitoring was performed and extravascular lung water index (EVLWI) assessed. An implanted device with a right ventricular lead measured Z using different electrode configurations. All animals developed gradual pulmonary fluid accumulation leading to inclining lung oedema: EVLWI did increase from 9.5 +/- 1 to 21.1 +/- 5.1 mL/kg (+127%). A concomitant decrease of Z by up to 23%, depending on the electrode configuration, was observed and regression analysis between Z and EVLWI yielded a significant inverse correlation. Changes of Z show a strong inverse correlation with changes of directly measured EVLWI. This allows the application of Z as a measure of intrathoracic fluid status and has the potential to optimize patient care, especially in the context of evolving telemedicine concepts.
引用
收藏
页码:731 / 740
页数:10
相关论文
共 30 条
[11]  
HENSEL B, 2004, SENSORS MED HLTH CAR, P283
[12]   INCIDENCE OF EPINEPHRINE-INDUCED PULMONARY-EDEMA IN RABBITS AND ACCOMPANYING METABOLIC CHANGES [J].
ISHIKAWA, N ;
HAGINO, Y ;
SHIGEI, T .
JAPANESE JOURNAL OF PHARMACOLOGY, 1975, 25 (06) :681-686
[13]   Accuracy of transpulmonary thermodilution versus gravimetric measurement of extravascular lung water [J].
Katzenelson, R ;
Perel, A ;
Berkenstadt, H ;
Preisman, S ;
Kogan, S ;
Sternik, L ;
Segal, E .
CRITICAL CARE MEDICINE, 2004, 32 (07) :1550-1554
[14]   Clinical deterioration in established heart failure: What is the value of BNP and weight gain in aiding diagnosis? [J].
Lewin, J ;
Ledwidge, M ;
O'Loughlin, C ;
McNally, C ;
McDonald, K .
EUROPEAN JOURNAL OF HEART FAILURE, 2005, 7 (06) :953-957
[15]   TRANSTHORACIC ELECTRICAL IMPEDANCE - QUANTITATIVE EVALUATION OF A NON-INVASIVE MEASURE OF THORACIC FLUID VOLUME [J].
LUEPKER, RV ;
MICHAEL, JR ;
WARBASSE, JR .
AMERICAN HEART JOURNAL, 1973, 85 (01) :83-93
[16]   Intrathoracic impedance monitoring to detect chronic heart failure deterioration:: Relationship to changes in NT proBNP [J].
Luethje, Lars ;
Vollmann, Dirk ;
Drescher, Till ;
Schott, Peter ;
Zenker, Dieter ;
Hasenfuss, Gerd ;
Unterberg, Christina .
EUROPEAN JOURNAL OF HEART FAILURE, 2007, 9 (6-7) :716-722
[17]   RADIOGRAPHIC PULMONARY CONGESTION IN END-STAGE CONGESTIVE HEART-FAILURE [J].
MAHDYOON, H ;
KLEIN, R ;
EYLER, W ;
LAKIER, JB ;
CHAKKO, SC ;
GHEORGHIADE, M .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (09) :625-627
[18]   Daily shock impedance measured by Implantable Cardioverter defibrillator is useful in the management of congestive heart failure [J].
Matsushita, Kohei ;
Ishikawa, Toshiyuki ;
Sumita, Shinichi ;
Kobayashi, Tsukasa ;
Ogawa, Hideyuki ;
Inoue, Noriko ;
Matsumoto, Katsumi ;
Taima, Minoru ;
Nakazawa, Ichirou ;
Sugano, Teruyasu ;
Ishigarni, Tomoaki ;
Uchino, Kazuaki ;
Umemura, Satoshi .
CIRCULATION JOURNAL, 2006, 70 (11) :1462-1465
[19]   Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction [J].
Moss, AJ ;
Zareba, W ;
Hall, WJ ;
Klein, H ;
Wilber, DJ ;
Cannom, DS ;
Daubert, JP ;
Higgins, SL ;
Brown, MW ;
Andrews, ML .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (12) :877-883
[20]   CLINICAL EVALUATION OF TRANSTHORACIC ELECTRICAL IMPEDANCE AS A GUIDE TO INTRATHORACIC FLUID VOLUMES [J].
POMERANTZ, M ;
DELGADO, F ;
EISEMAN, B .
ANNALS OF SURGERY, 1970, 171 (05) :686-+