Device-based impedance measurement is a useful and accurate tool for direct assessment of intrathoracic fluid accumulation in heart failure

被引:16
作者
Becher, Jan [1 ]
Kaufmann, Susann G. [1 ]
Paule, Stefan [2 ]
Fahn, Bernhard [2 ]
Skerl, Olaf [2 ]
Bauer, Wolfgang R. [1 ]
Ertl, Georg [1 ]
Maier, Sebastian K. G. [1 ]
机构
[1] Univ Klinikum, Med Klin & Poliklin 1, D-97080 Wurzburg, Germany
[2] BIOTRONIK GmbH & Co KG, Erlangen, Germany
来源
EUROPACE | 2010年 / 12卷 / 05期
关键词
Impedance; Devices; Telemedicine; Heart failure; Patient management; IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR; TRANSTHORACIC ELECTRICAL-IMPEDANCE; CARDIAC-RESYNCHRONIZATION THERAPY; RATE-VARIABILITY; PULMONARY-EDEMA; DETERIORATION; THERMODILUTION; FEASIBILITY; CONGESTION; PRESSURE;
D O I
10.1093/europace/eup413
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Heart failure patients are often equipped with implanted devices and are frequently hospitalized due to volume overload. Reliable prediction of imminent fluid congestion has the potential to provide early detection of cardiac decompensation and therefore might be capable of enhancing therapy management. We investigated whether implant-based impedance (Z) measurement is closely correlated with directly assessed extravascular lung water and might thus be useful for patient monitoring. In sheep, pulmonary fluid congestion was induced. Continuous haemodynamic monitoring was performed and extravascular lung water index (EVLWI) assessed. An implanted device with a right ventricular lead measured Z using different electrode configurations. All animals developed gradual pulmonary fluid accumulation leading to inclining lung oedema: EVLWI did increase from 9.5 +/- 1 to 21.1 +/- 5.1 mL/kg (+127%). A concomitant decrease of Z by up to 23%, depending on the electrode configuration, was observed and regression analysis between Z and EVLWI yielded a significant inverse correlation. Changes of Z show a strong inverse correlation with changes of directly measured EVLWI. This allows the application of Z as a measure of intrathoracic fluid status and has the potential to optimize patient care, especially in the context of evolving telemedicine concepts.
引用
收藏
页码:731 / 740
页数:10
相关论文
共 30 条
[1]   Continuous autonomic assessment in patients with symptomatic heart failure - Prognostic value of heart rate variability measured by an implanted cardiac resynchronization device [J].
Adamson, PB ;
Smith, AL ;
Abraham, WT ;
Kleckner, KJ ;
Stadler, RW ;
Shih, A ;
Rhodes, MM .
CIRCULATION, 2004, 110 (16) :2389-2394
[2]   Ongoing right ventricular hemodynarnics in heart failure -: Clinical value of measurements derived from an implantable monitoring system [J].
Adamson, PB ;
Magalski, A ;
Braunschweig, F ;
Böhm, M ;
Reynolds, D ;
Steinhaus, D ;
Luby, A ;
Linde, C ;
Ryden, L ;
Cremers, B ;
Takle, T ;
Bennett, T .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (04) :565-571
[3]   Equivalence of the bioimpedance and thermodilution methods in measuring cardiac output in hospitalized patients with advanced, decompensated chronic heart failure [J].
Albert, NM ;
Hail, MD ;
Li, JB ;
Young, JB .
AMERICAN JOURNAL OF CRITICAL CARE, 2004, 13 (06) :469-479
[4]   Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [J].
Bardy, GH ;
Lee, KL ;
Mark, DB ;
Poole, JE ;
Packer, DL ;
Boineau, R ;
Domanski, M ;
Troutman, C ;
Anderson, J ;
Johnson, G ;
McNulty, SE ;
Clapp-Channing, N ;
Davidson-Ray, LD ;
Fraulo, ES ;
Fishbein, DP ;
Luceri, RM ;
Ip, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) :225-237
[5]   Relationships between volume and pressure measurements and stroke volume in critically ill patients [J].
Bindels, AJGH ;
van der Hoeven, JG ;
Graafland, AD ;
de Koning, J ;
Meinders, AE .
CRITICAL CARE, 2000, 4 (03) :193-199
[6]   Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure [J].
Bristow, MR ;
Saxon, LA ;
Boehmer, J ;
Krueger, S ;
Kass, DA ;
De Marco, T ;
Carson, P ;
DiCarlo, L ;
DeMets, D ;
White, BG ;
DeVries, DW ;
Feldman, AM .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (21) :2140-2150
[7]   The effect of cardiac resynchronization on morbidity and mortality in heart failure [J].
Cleland, JGF ;
Daubert, J ;
Erdmann, E ;
Freemantle, N ;
Gras, D ;
Kappenberger, L ;
Tavazzi, L ;
Cleland, JGF ;
Daubert, JC ;
Erdmann, E ;
Gras, D ;
Kappenberger, L ;
Klein, W ;
Tavazzi, L ;
Poole-Wilson, PA ;
Rydén, L ;
Wedel, H ;
Wellens, HJJ ;
Uretsky, B ;
Thygesen, K ;
Böcker, D ;
Marijianowski, MMH ;
Freemantle, N ;
Calvert, MJ ;
Christ, G ;
Fruhwald, F ;
Hofmann, R ;
Krypta, A ;
Leisch, F ;
Pacher, R ;
Rauscha, F ;
Tavernier, R ;
Thomsen, PEB ;
Boesgaard, S ;
Eiskjær, H ;
Esperen, GT ;
Haarbo, J ;
Hagemann, A ;
Korup, E ;
Moller, M ;
Mortensen, P ;
Sogaard, P ;
Vesterlund, T ;
Huikuri, H ;
Niemelä, KI ;
Toivonen, L ;
Bauer, F ;
Cohen-Solal, A ;
Crocq, C ;
Djiane, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (15) :1539-1549
[8]  
COTTIS R, 2003, CRIT CARE NURSE, V19, P301
[9]   PLASMA BRAIN NATRIURETIC PEPTIDE IN ASSESSMENT OF ACUTE DYSPNEA [J].
DAVIS, M ;
ESPINER, E ;
RICHARDS, G ;
BILLINGS, J ;
TOWN, I ;
NEILL, A ;
DRENNAN, C ;
RICHARDS, M ;
TURNER, J ;
YANDLE, T .
LANCET, 1994, 343 (8895) :440-444
[10]   Cardiac resynchronization therapy improves heart rate profile and heart rate variability of patients with moderate to severe heart failure [J].
Fantoni, C ;
Raffa, S ;
Regoli, F ;
Giraldi, F ;
La Rovere, MT ;
Prentice, J ;
Pastori, F ;
Fratini, S ;
Salerno-Uriarte, JA ;
Klein, HU ;
Auricchio, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (10) :1875-1882