A Review of Hemolysis Prediction Models for Computational Fluid Dynamics

被引:85
作者
Yu, Hai [1 ]
Engel, Sebastian [1 ]
Janiga, Gabor [1 ]
Thevenin, Dominique [1 ]
机构
[1] Otto von Guericke Univ, Inst Fluid Dynam & Thermodynam, Lab Fluid Dynam & Tech Flows, Magdeburg, Germany
关键词
Computational fluid dynamics; Blood pump; Hemolysis estimation; Model comparison; Model validation; INDUCED PLATELET ACTIVATION; FLOW-INDUCED HEMOLYSIS; BLOOD DAMAGE; SHEAR-STRESS; MECHANICAL FRAGILITY; LATTICE-BOLTZMANN; HEART-VALVE; SIMULATION; CELLS; ACCUMULATION;
D O I
10.1111/aor.12871
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Flow-induced hemolysis is a crucial issue for many biomedical applications; in particular, it is an essential issue for the development of blood-transporting devices such as left ventricular assist devices, and other types of blood pumps. In order to estimate red blood cell (RBC) damage in blood flows, many models have been proposed in the past. Most models have been validated by their respective authors. However, the accuracy and the validity range of these models remains unclear. In this work, the most established hemolysis models compatible with computational fluid dynamics of full-scale devices are described and assessed by comparing two selected reference experiments: a simple rheometric flow and a more complex hemodialytic flow through a needle. The quantitative comparisons show very large deviations concerning hemolysis predictions, depending on the model and model parameter. In light of the current results, two simple power-law models deliver the best compromise between computational efficiency and obtained accuracy. Finally, hemolysis has been computed in an axial blood pump. The reconstructed geometry of a HeartMate II shows that hemolysis occurs mainly at the tip and leading edge of the rotor blades, as well as at the leading edge of the diffusor vanes.
引用
收藏
页码:603 / 621
页数:19
相关论文
共 71 条
[21]   Testing of Models of Flow-Induced Hemolysis in Blood Flow Through Hypodermic Needles [J].
Chen, Yangsheng ;
Kent, Timothy L. ;
Sharp, M. Keith .
ARTIFICIAL ORGANS, 2013, 37 (03) :256-266
[22]   A Strain-Based Flow-Induced Hemolysis Prediction Model Calibrated by In Vitro Erythrocyte Deformation Measurements [J].
Chen, Yangsheng ;
Sharp, M. Keith .
ARTIFICIAL ORGANS, 2011, 35 (02) :145-156
[23]   Hydrodynamic damage to animal cells [J].
Chisti, Y .
CRITICAL REVIEWS IN BIOTECHNOLOGY, 2001, 21 (02) :67-110
[24]   Numerical calculation of hemolysis levels in peripheral hemodialysis cannulas [J].
De Wachter, D ;
Verdonck, P .
ARTIFICIAL ORGANS, 2002, 26 (07) :576-582
[25]   Impact of oxygenator design on hemolysis, shear stress, and white blood cell and platelet counts [J].
DeSomer, F ;
Foubert, L ;
Vanackere, M ;
Dujardin, D ;
Delanghe, J ;
VanNooten, G .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1996, 10 (07) :884-889
[26]   ELASTIC AREA COMPRESSIBILITY MODULUS OF RED-CELL MEMBRANE [J].
EVANS, EA ;
WAUGH, R ;
MELNIK, L .
BIOPHYSICAL JOURNAL, 1976, 16 (06) :585-595
[27]   A Strain-Based Model for Mechanical Hemolysis Based on a Coarse-Grained Red Blood Cell Model [J].
Ezzeldin, Hussein M. ;
de Tullio, Marco D. ;
Vanella, Marcos ;
Solares, Santiago D. ;
Balaras, Elias .
ANNALS OF BIOMEDICAL ENGINEERING, 2015, 43 (06) :1398-1409
[28]   Asymptotically consistent a numerical approximation of hemolysis [J].
Farinas, Marie-Isabelle ;
Garon, Andre ;
Lacasse, David ;
N'dri, Donatien .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (05) :688-696
[29]   Fast three-dimensional numerical hemolysis approximation [J].
Garon, A ;
Farinas, MI .
ARTIFICIAL ORGANS, 2004, 28 (11) :1016-1025
[30]   ESTIMATION OF SHEAR STRESS-RELATED BLOOD DAMAGE IN HEART-VALVE PROSTHESES - INVITRO COMPARISON OF 25 AORTIC VALVES [J].
GIERSIEPEN, M ;
WURZINGER, LJ ;
OPITZ, R ;
REUL, H .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1990, 13 (05) :300-306