Evaluation of Dynamic Tumor-tracking Intensity-modulated Radiotherapy for Locally Advanced Pancreatic Cancer

被引:13
作者
Nakamura, Akira [1 ]
Hiraoka, Masahiro [1 ]
Itasaka, Satoshi [2 ]
Nakamura, Mitsuhiro [1 ]
Akimoto, Mami [1 ]
Ishihara, Yoshitomo [1 ]
Mukumoto, Nobutaka [1 ]
Goto, Yoko [1 ]
Kishi, Takahiro [1 ]
Yoshimura, Michio [1 ]
Matsuo, Yukinori [1 ]
Yano, Shinsuke [1 ]
Mizowaki, Takashi [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Radiat Oncol & Image Appl Therapy, Kyoto, Japan
[2] Kurashiki Cent Hosp, Dept Radiat Oncol, Kurashiki, Okayama, Japan
来源
SCIENTIFIC REPORTS | 2018年 / 8卷
关键词
INTRAFRACTIONAL MOTION; ORGAN MOTION; IMRT; GEMCITABINE; ACCURACY; SYSTEM; MANAGEMENT; TOXICITY; MARKER;
D O I
10.1038/s41598-018-35402-7
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Intensity-modulated radiotherapy (IMRT) is now regarded as an important treatment option for patients with locally advanced pancreatic cancer (LAPC). To reduce the underlying tumor motions and dosimetric errors during IMRT as well as the burden of respiratory management for patients, we started to apply a new treatment platform of the dynamic tumor dynamic tumor-tracking intensity-modulated radiotherapy (DTT-IMRT) using the gimbaled linac, which can swing IMRT toward the real-time tumor position under patients' voluntary breathing. Between June 2013 and March 2015, ten patients were treated, and the tumor-tracking accuracy and the practical benefits were evaluated. The mean PTV size in DTT-IMRT was 18% smaller than a conventional ITV-based PTV. The root-mean-squared errors between the predicted and the detected tumor positions were 1.3, 1.2, and 1.5 mm in left-right, anterior-posterior, and cranio-caudal directions, respectively. The mean in-room time was 24.5 min. This high-accuracy of tumor-tracking with reasonable treatment time are promising and beneficial to patients with LAPC.
引用
收藏
页数:10
相关论文
共 47 条
  • [1] Predictive uncertainty in infrared marker-based dynamic tumor tracking with Vero4DRT
    Akimoto, Mami
    Nakamura, Mitsuhiro
    Mukumoto, Nobutaka
    Tanabe, Hiroaki
    Yamada, Masahiro
    Matsuo, Yukinori
    Monzen, Hajime
    Mizowaki, Takashi
    Kokubo, Masaki
    Hiraoka, Masahiro
    [J]. MEDICAL PHYSICS, 2013, 40 (09)
  • [2] [Anonymous], 2018, NCCN Clinical Practice Guidelines in Oncology, DOI DOI 10.1016/B978-0-323-35762-3.00092-5
  • [3] A Phase I/II Trial of Intensity Modulated Radiation (IMRT) Dose Escalation With Concurrent Fixed-dose Rate Gemcitabine (FDR-G) in Patients With Unresectable Pancreatic Cancer
    Ben-Josef, Edgar
    Schipper, Mathew
    Francis, Isaac R.
    Hadley, Scott
    Ten-Haken, Randall
    Lawrence, Theodore
    Normolle, Daniel
    Simeone, Diane M.
    Sonnenday, Christopher
    Abrams, Ross
    Leslie, William
    Khan, Gazala
    Zalupski, Mark M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (05): : 1166 - 1171
  • [4] Comparison of toxicity after IMRT and 3D-conformal radiotherapy for patients with pancreatic cancer - A systematic review
    Bittner, Martin-Immanuel
    Grosu, Anca-Ligia
    Brunner, Thomas B.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 114 (01) : 117 - 121
  • [5] The first patient treatment of electromagnetic-guided real time adaptive radiotherapy using MLC tracking for lung SABR
    Booth, Jeremy T.
    Caillet, Vincent
    Hardcastle, Nicholas
    O'Brien, Ricky
    Szymura, Kathryn
    Crasta, Charlene
    Harris, Benjamin
    Haddad, Carol
    Eade, Thomas
    Keall, Paul J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 121 (01) : 19 - 25
  • [6] Effects of motion on the total dose distribution
    Bortfeld, T
    Jiang, SB
    Rietzel, E
    [J]. SEMINARS IN RADIATION ONCOLOGY, 2004, 14 (01) : 41 - 51
  • [7] Hypofractionated ablative radiotherapy for locally advanced pancreatic cancer
    Crane, Christopher H.
    [J]. JOURNAL OF RADIATION RESEARCH, 2016, 57 : I53 - I57
  • [8] Real-time intra-fraction-motion tracking using the treatment couch: a feasibility study
    D'Souza, WD
    Naqvi, SA
    Yu, CX
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (17) : 4021 - 4033
  • [9] DEKOSTE JRV, 2018, INT J RAD ONCOL BIOL
  • [10] Initial assessment of tumor tracking with a gimbaled linac system in clinical circumstances: A patient simulation study
    Depuydt, Tom
    Poels, Kenneth
    Verellen, Dirk
    Engels, Benedikt
    Collen, Christine
    Haverbeke, Chloe
    Gevaert, Thierry
    Buls, Nico
    Van Gompel, Gert
    Reynders, Truus
    Duchateau, Michael
    Tournel, Koen
    Boussaer, Marlies
    Steenbeke, Femke
    Vandenbroucke, Frederik
    De Ridder, Mark
    [J]. RADIOTHERAPY AND ONCOLOGY, 2013, 106 (02) : 236 - 240