An unshielded radio-frequency atomic magnetometer with sub-femtoTesla sensitivity

被引:38
作者
Keder, David A. [1 ]
Prescott, David W. [1 ]
Conovaloff, Adam W. [1 ]
Sauer, Karen L. [1 ]
机构
[1] George Mason Univ, Sch Phys Astron & Computat Sci, Fairfax, VA 22030 USA
基金
美国国家科学基金会;
关键词
NUCLEAR-QUADRUPOLE RESONANCE; OPTICAL MAGNETOMETRY; SQUID AMPLIFIER; ENVIRONMENT; MRI;
D O I
10.1063/1.4905449
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
We demonstrate a radio-frequency potassium-vapor magnetometer operating with sensitivities of 0.3 fT/root Hz at 0.5 MHz and 0.9 fT/root Hz at 1.31 MHz in the absence of radio-frequency and mu-metal or magnetic shielding. The use of spatially separated magnetometers, two voxels within the same cell, permits for the subtraction of common mode noise and the retention of a gradient signal, as from a local source. At 0.5 MHz the common mode noise was white and measured to be 3.4 fT/root Hz; upon subtraction the noise returned to the values observed when the magnetometer was shielded. At 1.31 MHz, the common mode noise was from a nearby radio station and was reduced by a factor of 33 upon subtraction, limited only by the radio signal picked up by receiver electronics. Potential applications include in-the-field low-field magnetic resonance, such as the use of nuclear quadrupole resonance for the detection of explosives. (C) 2014 Author(s). All article content, except where otherwise noted, is licensed under a Creative Commons Attribution 3.0 Unported License.
引用
收藏
页数:5
相关论文
共 27 条
[1]   An all-optical, high-sensitivity magnetic gradiometer [J].
Affolderbach, C ;
Stähler, M ;
Knappe, S ;
Wynands, R .
APPLIED PHYSICS B-LASERS AND OPTICS, 2002, 75 (6-7) :605-612
[2]   Spin damping in an rf atomic magnetometer [J].
Alem, Orang ;
Sauer, Karen L. ;
Romalis, Mike V. .
PHYSICAL REVIEW A, 2013, 87 (01)
[3]  
[Anonymous], 2013, REC ITU R PI 372 11
[4]   Cesium coherent population trapping magnetometer for cardiosignal detection in an unshielded environment [J].
Belfi, J. ;
Bevilacqua, G. ;
Biancalana, V. ;
Cartaleva, S. ;
Dancheva, Y. ;
Moi, L. .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2007, 24 (09) :2357-2362
[5]   All-optical magnetometry for NMR detection in a micro-Tesla field and unshielded environment [J].
Bevilacqua, G. ;
Biancalana, V. ;
Dancheva, Y. ;
Moi, L. .
JOURNAL OF MAGNETIC RESONANCE, 2009, 201 (02) :222-229
[6]   Optical magnetometry [J].
Budker, Dmitry ;
Romalis, Michael .
NATURE PHYSICS, 2007, 3 (04) :227-234
[7]   Room temperature femtotesla radio-frequency atomic magnetometer [J].
Chalupczak, W. ;
Godun, R. M. ;
Pustelny, S. ;
Gawlik, W. .
APPLIED PHYSICS LETTERS, 2012, 100 (24)
[8]   Remote sensing by nuclear quadrupole resonance [J].
Garroway, AN ;
Buess, ML ;
Miller, JB ;
Suits, BH ;
Hibbs, AD ;
Barrall, GA ;
Matthews, R ;
Burnett, LJ .
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2001, 39 (06) :1108-1118
[9]   N-14 NQR using a high-Tc rf SQUID with a normal metal transformer [J].
He, D. F. ;
Tachiki, M. ;
Itozaki, H. .
SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2008, 21 (01)
[10]   Multi-channel atomic magnetometer for magnetoencephalography: A configuration study [J].
Kim, Kiwoong ;
Begus, Samo ;
Xia, Hui ;
Lee, Seung-Kyun ;
Jazbinsek, Vojko ;
Trontelj, Zvonko ;
Romalis, Michael V. .
NEUROIMAGE, 2014, 89 :143-151