A Wire-Crossed-Loop Resonator for Rapid Scan EPR

被引:22
作者
Rinard, George A. [2 ]
Quine, Richard W. [2 ]
Biller, Joshua R. [1 ]
Eaton, Gareth R. [1 ]
机构
[1] Univ Denver, Dept Chem & Biochem, Denver, CO 80208 USA
[2] Univ Denver, Dept Elect Engn, Denver, CO 80208 USA
关键词
bimodal resonator; isolation; rapid scan;
D O I
10.1002/cmr.b.20161
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A crossed-loop (orthogonal mode) resonator (CLR) was constructed of fine wire to achieve design goals for rapid scan in vivo EPR imaging at VHF frequencies (in practice, near 250 MHz). This application requires the resonator to have a very open design to facilitate access to the animal for physiological support during the image acquisition. The rapid scan experiment uses large amplitude magnetic field scans, and sufficiently large resonator and detection bandwidths to record the rapidly-changing signal response. Rapid-scan EPR is sensitive to RF/microwave source noise and to baseline changes that are coherent with the field scan. The sensitivity to source noise is a primary incentive for using a CLR to isolate the detected signal from the RF source noise. Isolation from source noise of 44 and 47 dB was achieved in two resonator designs. Prior results showed that eddy currents contribute to background problems in rapid scan EPR, so the CLR design had to minimize conducting metal components. Using fine (AWG 38) wire for the resonators decreased eddy currents and lowered the resonator 0, thus providing larger resonator bandwidth. Mechanical resonances at specific scan frequencies are a major contributor to rapid scan backgrounds. (C) 2010 Wiley Periodicals, Inc. Concepts Magn Reson Part B (Magn Reson Engineering) 37B: 86-91, 2010
引用
收藏
页码:86 / 91
页数:6
相关论文
共 13 条
[1]  
BALANIS CA, 1982, ANTENNA THEORY ANAL, P365
[2]  
Hyde J.H., 1989, ADV EPR APPL BIOL BI, P277
[3]   A pulsed and continuous wave 250 MHz electron paramagnetic resonance spectrometer [J].
Ouine, RW ;
Rinard, GA ;
Eaton, SS ;
Eaton, GR .
CONCEPTS IN MAGNETIC RESONANCE, 2002, 15 (01) :59-91
[4]   Bimodal loop-gap resonator [J].
Piasecki, W ;
Froncisz, W ;
Hyde, JS .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (05) :1896-1904
[5]   250 MHz crossed-loop electron paramagnetic resonator for pulsed resonance [J].
Rinard, GA ;
Ouine, RW ;
Eaton, GR ;
Eaton, SS .
CONCEPTS IN MAGNETIC RESONANCE, 2002, 15 (01) :37-46
[6]   Easily tunable crossed-loop (bimodal) EPR resonator [J].
Rinard, GA ;
Quine, RW ;
Ghim, BT ;
Eaton, SS ;
Eaton, GR .
JOURNAL OF MAGNETIC RESONANCE SERIES A, 1996, 122 (01) :50-57
[7]   Dispersion and superheterodyne EPR using a bimodal resonator [J].
Rinard, GA ;
Quine, RW ;
Ghim, BT ;
Eaton, SS ;
Eaton, GR .
JOURNAL OF MAGNETIC RESONANCE SERIES A, 1996, 122 (01) :58-63
[8]   An L-band crossed-loop (bimodal) EPR resonator [J].
Rinard, GA ;
Quine, RW ;
Eaton, GR .
JOURNAL OF MAGNETIC RESONANCE, 2000, 144 (01) :85-88
[9]   MICROWAVE SUPERHETERODYNE INDUCTION SPECTROMETER [J].
TEANEY, DT ;
KLEIN, MP ;
PORTIS, AM .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1961, 32 (06) :721-&
[10]   BIMODAL LOOP GAP RESONATOR [J].
TSAPIN, AI ;
HYDE, JS ;
FRONCISZ, W .
JOURNAL OF MAGNETIC RESONANCE, 1992, 100 (03) :484-490