Measuring and rating the energy-efficiency of servers

被引:1
作者
von Kistowski, Joakim [1 ]
Lange, Klaus-Dieter [2 ]
Arnold, Jeremy A. [3 ]
Beckett, John [4 ]
Block, Hansfried [5 ]
Tricker, Mike [6 ]
Sharma, Sanjay [7 ]
Pais, Johann [8 ]
Kounev, Samuel [1 ]
机构
[1] Univ Wurzburg, D-97074 Wurzburg, Germany
[2] Hewlett Packard Enterprise, 11445 Compaq Ctr Dr W, Houston, TX 77070 USA
[3] IBM Corp, 3605 Hwy 52 N, Rochester, MN 55902 USA
[4] Dell Inc, One Dell Way,Mailstop RR5-18, Round Rock, TX 78682 USA
[5] SPECpower Comm, 7001 Heritage Village Plaza,S225, Gainesville, VA USA
[6] Microsoft Corp, One Microsoft Way, Redmond, WA 98052 USA
[7] Intel Corp, 5000 W Chandler Blvd,MS CH7-401, Chandler, AZ 85248 USA
[8] Adv Micro Devices Inc, 7171 Southwest Pkwy, Austin, TX 78735 USA
来源
FUTURE GENERATION COMPUTER SYSTEMS-THE INTERNATIONAL JOURNAL OF ESCIENCE | 2019年 / 100卷
关键词
Server; Energy-efficiency; Benchmarking; Measurement methodology; Metric;
D O I
10.1016/j.future.2019.05.050
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Data centers and servers consume a significant amount of electrical power. As future data centers increase in size, it becomes increasingly important to be able to select servers based on their energy efficiency. Rating the efficiency of servers is challenging, as it depends on the software executed on that server and on its load profile. To account for this, a measurement and rating methodology for servers must make use of both realistic and varying workloads. Existing energy-efficiency benchmarks either run standardized application loads at multiple load levels or multiple micro-benchmarks at full load. This does not enable a full analysis of system behavior as the energy efficiency for different kinds of software at low load levels remains unknown. This article introduces a measurement methodology and metrics for energy-efficiency rating of servers. The methodology defines system setup and instrumentation for reproducible results. It is designed to use multiple, specifically chosen workloads at different load levels for a full system characterization. All partial results are aggregated in a final metric that can be used by regulators to define server-labeling criteria. The methodology and workloads have been implemented in the standardized Server Efficiency Rating Tool. We show the applicability and use of the measurement methodology specifically considering its reproducibility, fairness, and relevance. A reproducibility analysis shows that efficiency scores vary with a maximum coefficient of 1.04% for repeated experiments. In addition, we evaluate the proposed metrics by investigating their energy-efficiency rating on a set of 385 different servers and show the relevance of the selected workloads by analyzing relationships to real-world applications. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:579 / 589
页数:11
相关论文
共 28 条
[1]  
[Anonymous], 2015, Int J Intell Comput Res, DOI DOI 10.20533/IJICR.2042.4655.2015.0078
[2]  
Arnold Jeremy, 2013, THESIS
[3]   An energy-aware service composition algorithm for multiple cloud-based IoT applications [J].
Baker, Thar ;
Asim, Muhammad ;
Tawfik, Hissam ;
Aldawsari, Bandar ;
Buyya, Rajkumar .
JOURNAL OF NETWORK AND COMPUTER APPLICATIONS, 2017, 89 :96-108
[4]   The case for energy-proportional computing [J].
Barroso, Luiz Andre ;
Hoelzle, Urs .
COMPUTER, 2007, 40 (12) :33-+
[5]  
Belady C., 2008, Green Grid Data Center Power Efficiency Metrics: PUE and DCiE
[6]  
Economou D, 2006, WORKSH MOD BENCHM SI
[7]   Mean value coordinates [J].
Floater, MS .
COMPUTER AIDED GEOMETRIC DESIGN, 2003, 20 (01) :19-27
[8]  
Glanz J., 2012, The New York Times
[9]   SPEC CPU2000: Measuring CPU performance in the new millennium [J].
Henning, JL .
COMPUTER, 2000, 33 (07) :28-+
[10]  
Hsu Chung-Hsing., 2015, P 6 ACMSPEC INT C PE, P235