Surface characterization of passive film on NiCr-based dental casting alloys

被引:46
作者
Huang, HH [1 ]
机构
[1] Chung Shan Med Univ, Inst Dent Mat, Taichung 402, Taiwan
关键词
passive film; polarization resistance; passive current density; passivating rate; passivity decay rate; NiCr-based alloy;
D O I
10.1016/S0142-9612(02)00544-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Surface characterization of passive film formed on different NiCr-based dental casting alloys in an acidic artificial saliva was investigated by using electrochemical impedance spectroscopy (EIS) measurement and potential decay test. The polarization resistance (R-p), which is inversely proportional to corrosion rate, of passive film was obtained from the EIS data. The stable passive current density, passivating rate, and passivity decay rate of passive film were evaluated by potential decay test. Surface chemical analyses of passive film were performed by using X-ray photoelectron spectrometer and Auger electron spectrometer. Results showed that the R-p, stable passive current density, passivating rate, and passivity decay rate, respectively, were significantly different among the various NiCr-based alloys (p<0.001). The presence of higher Cr (maximum 31-37at%; mainly as Cr2O3) and Mo (maximum 10-11 at%; mainly as MoO3) contents in the passive film led to a higher Rp, lower stable passive current density, faster passivating rate, and lower passivity decay rate. The presence of Be (> 20 at%; mainly as BeO) in the passive film was detrimental to both the corrosion resistance and the stability of passive film. The presence of small amount of Ti (< 6 at%; mainly as TiO2) in the passive film did not show any influence on the characterization of passive film. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1575 / 1582
页数:8
相关论文
共 31 条
[1]  
Anusavice KJ, 1996, PHILLIPS SCI DENT MA, V10th, P423
[2]   The effect of pH on the corrosion of dental metal alloys [J].
Bayramoglu, G ;
Alemdaroglu, T ;
Kedici, S ;
Aksüt, AA .
JOURNAL OF ORAL REHABILITATION, 2000, 27 (07) :563-575
[3]   In vitro and in vivo corrosion evaluation of nickel-chromium- and copper-aluminum-based alloys [J].
Benatti, OFM ;
Miranda, WG ;
Muench, A .
JOURNAL OF PROSTHETIC DENTISTRY, 2000, 84 (03) :360-363
[4]   A MICROCOMPUTER BASED SYSTEM FOR FREQUENCY-DEPENDENT IMPEDANCE ADMITTANCE MEASUREMENTS [J].
BOUKAMP, BA .
SOLID STATE IONICS, 1984, 11 (04) :339-346
[5]   SURFACE-ANALYSIS OF NICKEL-CHROMIUM DENTAL ALLOYS [J].
BUMGARDNER, JD ;
LUCAS, LC .
DENTAL MATERIALS, 1993, 9 (04) :252-259
[6]  
BUMGARDNER JD, 1998, P S BIOM ENG C IEEE, P45
[7]  
BUNDY KJ, 1994, CRIT REV BIOMED ENG, V22, P139
[8]  
COVINGTON JS, 1985, OPER DENT, V10, P93
[9]   BERYLLIUM LOCALIZATION IN BASE-METAL DENTAL CASTING ALLOYS [J].
COVINGTON, JS ;
MCBRIDE, MA ;
SLAGLE, WF ;
DISNEY, AL .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1985, 19 (07) :747-750
[10]  
GEIS-GERSTORFER J, 1991, International Journal of Prosthodontics, V4, P152