Back-to-back colon capsule endoscopy and optical colonoscopy in colorectal cancer screening individuals

被引:61
作者
Kobaek-Larsen, M. [1 ,2 ]
Kroijer, R. [1 ,2 ]
Dyrvig, A. -K. [1 ,2 ,3 ]
Buijs, M. M. [1 ,2 ]
Steele, R. J. C. [4 ,5 ]
Qvist, N. [1 ,2 ]
Baatrup, G. [1 ,2 ]
机构
[1] Odense Univ Hosp, Dept Surg, Odense, Denmark
[2] Univ Southern Denmark, Dept Clin Res, Odense, Denmark
[3] Odense Univ Hosp, Odense Patient Data Explorat Network, OPEN, Odense, Denmark
[4] Dundee Univ Hosp, Dundee, Scotland
[5] Natl Screening Ctr, Dundee, Scotland
关键词
Colon capsule endoscopy; colonoscopy; colorectal cancer screening; OCCULT BLOOD-TEST; SURVEILLANCE; POPULATION; ACCURACY; POLYPS;
D O I
10.1111/codi.13965
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Aim The aim was to determine the polyp detection rate and per-patient sensitivity for polyps > 9 mm of colon capsule endoscopy (CCE) compared with colonoscopy as well as the diagnostic accuracy of CCE. Method Individuals who had a positive immunochemical faecal occult blood test during screening had investigator blinded CCE and colonoscopy. Participants underwent repeat endoscopy if significant lesions detected by CCE were considered to have been missed by colonoscopy. Results There were 253 participants. The polyp detection rate was significantly higher in CCE compared with colonoscopy (P=0.02). The per-patient sensitivity for > 9 mm polyps for CCE and colonoscopy was 87% (95% CI: 83-91%) and 88% (95% CI: 84-92%) respectively. In participants with complete CCE and colonoscopy examinations (N=126), per-patient sensitivity of > 9 mm polyps in CCE (97%; 95% CI: 94-100%) was superior to colonoscopy (89%; 95% CI: 84-94%). A complete capsule endoscopy examination (N=134) could detect patients with intermediate or greater risk (according to the European guidelines) with an accuracy, sensitivity, specificity and positivity rate of 79%, 93%, 69% and 58% respectively, using a cut-off of at least one polyp > 10 mm or more than two polyps. Conclusion CCE is superior to colonoscopy in polyp detection rate and per-patient sensitivity to > 9 mm polyps, but only in complete CCE examinations. The rate of incomplete CCE examinations must be improved.
引用
收藏
页码:479 / 485
页数:7
相关论文
共 11 条
[1]   Post-polypectomy colonoscopy surveillance: European Society of Gastrointestinal Endoscopy (ESGE) Guideline [J].
Hassan, Cesare ;
Quintero, Enrique ;
Dumonceau, Jean-Marc ;
Regula, Jaroslaw ;
Brandao, Catarina ;
Chaussade, Stanislas ;
Dekker, Evelien ;
Dinis-Ribeiro, Mario ;
Ferlitsch, Monika ;
Gimeno-Garcia, Antonio ;
Hazewinkel, Yark ;
Jover, Rodrigo ;
Kalager, Mette ;
Loberg, Magnus ;
Pox, Christian ;
Rembacken, Bjorn ;
Lieberman, David .
ENDOSCOPY, 2013, 45 (10) :842-851
[2]   Miss rate for colorectal neoplastic polyps:: a prospective multicenter study of back-to-back video colonoscopies [J].
Heresbach, D. ;
Barrioz, T. ;
Lapalus, M. G. ;
Coumaros, D. ;
Bauret, P. ;
Potier, P. ;
Sautereau, D. ;
Boustiere, C. ;
Grimaud, J. C. ;
Barthelemy, C. ;
See, J. ;
Serraj, I. ;
Halluin, P. N. D. ;
Branger, B. ;
Ponchan, T. .
ENDOSCOPY, 2008, 40 (04) :284-290
[3]   Colon capsule endoscopy as possible filter test for colonoscopy selection in a screening population with positive fecal immunology [J].
Holleran, Grainne ;
Leen, Ronan ;
O'Morain, Colm ;
McNamara, Deirdre .
ENDOSCOPY, 2014, 46 (06) :473-478
[4]   Quality Indicators for Colonoscopy and the Risk of Interval Cancer [J].
Kaminski, Michal F. ;
Regula, Jaroslaw ;
Kraszewska, Ewa ;
Polkowski, Marcin ;
Wojciechowska, Urszula ;
Didkowska, Joanna ;
Zwierko, Maria ;
Rupinski, Maciej ;
Nowacki, Marek P. ;
Butruk, Eugeniusz .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 362 (19) :1795-1803
[5]   Sensitivity of immunochemical fecal occult blood test to small colorectal adenomas [J].
Morikawa, Tamiya ;
Kato, Jun ;
Yamaji, Yutaka ;
Wada, Ryoichi ;
Mitsushima, Toru ;
Sakaguchi, Kohsaku ;
Shiratori, Yasushi .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2007, 102 (10) :2259-2264
[6]   Accuracy of Capsule Colonoscopy in Detecting Colorectal Polyps in a Screening Population [J].
Rex, Douglas K. ;
Adler, Samuel N. ;
Aisenberg, James ;
Burch, Wilmot C., Jr. ;
Carretero, Cristina ;
Chowers, Yehuda ;
Fein, Steven A. ;
Fern, Steven E. ;
Fernandez-Urien Sainz, Ignacio ;
Fich, Alexander ;
Gal, Eyal ;
Horlander, John C., Sr. ;
Isaacs, Kim L. ;
Kariv, Revital ;
Lahat, Adi ;
Leung, Wai-Keung ;
Malik, Pramod R. ;
Morgan, Doug ;
Papageorgiou, Neofytos ;
Romeo, David P. ;
Shah, Smita S. ;
Waterman, Matti .
GASTROENTEROLOGY, 2015, 148 (05) :948-U388
[7]   Accuracy of Capsule Colonoscopy and Computed Tomographic Colonography in Individuals With Positive Results From the Fecal Occult Blood Test [J].
Rondonotti, Emanuele ;
Borghi, Claudia ;
Mandelli, Giovanna ;
Radaelli, Franco ;
Paggi, Silvia ;
Amato, Arnaldo ;
Imperiali, Gianni ;
Terreni, Natalia ;
Lenoci, Nicoletta ;
Terruzzi, Vittorio ;
Baccarin, Alessandra ;
Martegani, Alberto ;
Spinzi, Giancarlo .
CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2014, 12 (08) :1303-1310
[8]   Accuracy of First- and Second-Generation Colon Capsules in Endoscopic Detection of Colorectal Polyps: A Systematic Review and Meta-analysis [J].
Spada, Cristiano ;
Pasha, Shabana F. ;
Gross, Seth A. ;
Leighton, Jonathan A. ;
Schnoll-Sussman, Felice ;
Correale, Loredana ;
Suarez, Begona Gonzalez ;
Costamagna, Guido ;
Hassan, Cesare .
CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2016, 14 (11) :1533-+
[9]   Colon capsule versus CT colonography in patients with incomplete colonoscopy: a prospective, comparative trial [J].
Spada, Cristiano ;
Hassan, Cesare ;
Barbaro, Brunella ;
Iafrate, Franco ;
Cesaro, Paola ;
Petruzziello, Lucio ;
Grazioli, Leonardo Minelli ;
Senore, Carlo ;
Brizi, Gabriella ;
Costamagna, Isabella ;
Alvaro, Giuseppe ;
Iannitti, Marcella ;
Salsano, Marco ;
Ciolina, Maria ;
Laghi, Andrea ;
Bonomo, Lorenzo ;
Costamagna, Guido .
GUT, 2015, 64 (02) :272-281
[10]   Gastrografin as an alternative booster to sodium phosphate in colon capsule endoscopy: safety and efficacy pilot study [J].
Togashi, Kazutomo ;
Fujita, Tomoki ;
Utano, Kenichi ;
Waga, Eriko ;
Katsuki, Shinichi ;
Isohata, Noriyuki ;
Endo, Shungo ;
Lefor, Alan K. .
ENDOSCOPY INTERNATIONAL OPEN, 2015, 3 (06) :E659-E661