Quantifying Effect of Post-Tensioned Bars for Precast Concrete Shear Walls

被引:8
作者
Quoc To Bao [1 ]
Lee, Kihak [1 ]
Kim, Sung-Jig [2 ]
Shin, Jiuk [3 ]
机构
[1] Sejong Univ, Deep Learning Architecture Res Ctr, Dept Architectural Engn, 209 Neungdong Ro, Seoul 05006, South Korea
[2] Keimyung Univ, Dept Architectural Engn, Daegu 42601, South Korea
[3] Gyeongsang Natl Univ, Dept Architectural Engn, Jinju 52828, South Korea
基金
新加坡国家研究基金会;
关键词
post-tensioned; reinforced concrete shear wall; pushover analysis; finite element model; INCREMENTAL DYNAMIC-ANALYSIS; SEISMIC PERFORMANCE; RC BEAMS; BEHAVIOR; MODEL; DESIGN; IMPACT; DAMAGE; CONNECTIONS; TESTS;
D O I
10.3390/su14106141
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A hybrid concrete wall is made up of a traditional reinforced concrete wall with post-tensioned technology. Recent research has shown that post-tensioned (PT) reinforced concrete shear walls have a wide range of advantages when it comes to resisting lateral forces and lateral moments caused by earthquake loading. To explore the PT reinforced concrete wall behavior subjected to seismic load, the concrete models were augmented with various material models, including the KCC, CDP, and Winfrith models for a PT 2D wall under pushover analysis. To ensure that the overall behavior forecast was qualitatively acceptable, the models' performance was compared to experimental findings. Then, the post-tensioned modeling approach was implemented with the 3D wall in order to predict structural responses of the PT 3D wall. The well-validated finite element models were ultilized to estimate the effects of the post-tensioned bars on lateral resisting capacities of the precast concrete shear wall.
引用
收藏
页数:32
相关论文
共 55 条