Optimization of multiply acquired magnetic flux density Bz using ICNE-Multiecho train in MREIT

被引:30
作者
Nam, Hyun Soo [1 ]
Kwon, Oh In [1 ]
机构
[1] Konkuk Univ, Dept Math, Seoul, South Korea
关键词
ELECTRICAL-IMPEDANCE TOMOGRAPHY; IMAGE-RECONSTRUCTION; ONE-COMPONENT; CONDUCTIVITY; ALGORITHM; RESOLUTION; CONTRAST;
D O I
10.1088/0031-9155/55/9/021
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of magnetic resonance electrical impedance tomography (MREIT) is to visualize the electrical properties, conductivity or current density of an object by injection of current. Recently, the prolonged data acquisition time when using the injected current nonlinear encoding (ICNE) method has been advantageous for measurement of magnetic flux density data, Bz, for MREIT in the signal-to-noise ratio (SNR). However, the ICNE method results in undesirable side artifacts, such as blurring, chemical shift and phase artifacts, due to the long data acquisition under an inhomogeneous static field. In this paper, we apply the ICNE method to a gradient and spin echo (GRASE) multi-echo train pulse sequence in order to provide the multiple k-space lines during a single RF pulse period. We analyze the SNR of the measured multiple Bz data using the proposed ICNE-Multiecho MR pulse sequence. By determining a weighting factor for Bz data in each of the echoes, an optimized inversion formula for the magnetic flux density data is proposed for the ICNE-Multiecho MR sequence. Using the ICNE-Multiecho method, the quality of the measured magnetic flux density is considerably increased by the injection of a long current through the echo train length and by optimization of the voxel-by-voxel noise level of the Bz value. Agarose-gel phantom experiments have demonstrated fewer artifacts and a better SNR using the ICNE-Multiecho method. Experimenting with the brain of an anesthetized dog, we collected valuable echoes by taking into account the noise level of each of the echoes and determined Bz data by determining optimized weighting factors for the multiply acquired magnetic flux density data.
引用
收藏
页码:2743 / 2759
页数:17
相关论文
共 26 条
[11]   Uniqueness and convergence of conductivity image reconstruction in magnetic resonance electrical impedance tomography [J].
Kim, YJ ;
Kwon, O ;
Se, JK ;
Woo, EJ .
INVERSE PROBLEMS, 2003, 19 (05) :1213-1225
[12]  
KOWN O, 2007, PHYSIOL MEAS, V28, P1391
[13]   Magnetic resonance electrical impedance tomography (MREIT):: Simulation study of J-substitution algorithm [J].
Kwon, O ;
Woo, EJ ;
Yoon, JR ;
Seo, JK .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (02) :160-167
[14]   Three-dimensional forward solver and its performance analysis for magnetic resonance electrical impedance tomography (MREIT) using recessed electrodes [J].
Lee, BI ;
Oh, SH ;
Woo, EJ ;
Lee, SY ;
Cho, MH ;
Kwon, O ;
Seo, JK ;
Lee, JY ;
Baek, WS .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (13) :1971-1986
[15]   Resolution and contrast in magnetic resonance electrical impedance tomography (MREIT) and its application to cancer imaging [J].
Muftuler, LT ;
Hamamura, M ;
Birgul, O ;
Nalcioglu, O .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2004, 3 (06) :599-609
[16]   Conductivity imaging with low level current injection using transversal J-substitution algorithm in MREIT [J].
Nam, Hyun Soo ;
Lee, Byung Il ;
Choi, Jongsung ;
Park, Chunjae ;
Kwon, Oh In .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (22) :6717-6730
[17]   Electrical conductivity images of biological tissue phantoms in MREIT [J].
Oh, SH ;
Lee, BI ;
Woo, EJ ;
Lee, SY ;
Kim, TS ;
Kwon, O ;
Seo, JK .
PHYSIOLOGICAL MEASUREMENT, 2005, 26 (02) :S279-S288
[18]   Conductivity and current density image reconstruction using harmonic Bz algorithm in magnetic resonance electrical impedance tomography [J].
Oh, SH ;
Lee, BI ;
Woo, EJ ;
Lee, SY ;
Cho, MH ;
Kwon, O ;
Seo, JK .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (19) :3101-3116
[19]   Static conductivity imaging using variational gradient Bz algorithm in magnetic resonance electrical impedance tomography [J].
Park, C ;
Park, EJ ;
Woo, EJ ;
Kwon, O ;
Seo, JK .
PHYSIOLOGICAL MEASUREMENT, 2004, 25 (01) :257-269
[20]   Electrical conductivity imaging using gradient Bz decomposition algorithm in magnetic resonance electrical impedance tomography (MREIT) [J].
Park, C ;
Kwon, O ;
Woo, EJ ;
Seo, JK .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (03) :388-394