Precision of 3D Registration Analysis for Longitudinal Study of Second-Generation HR-pQCT

被引:9
作者
Chiba, Ko [1 ]
Okazaki, Narihiro [1 ]
Isobe, Yusaku [2 ]
Miyazaki, Satsuki [2 ]
Yonekura, Akihiko [1 ]
Tomita, Masato [1 ]
Osaki, Makoto [1 ]
机构
[1] Nagasaki Univ, Dept Orthoped Surg, Grad Sch Biomed Sci, 1-7-1 Sakamoto, Nagasaki 8528501, Japan
[2] Nagasaki Univ, Sch Med, Nagasaki, Japan
关键词
HR-pQCT; second-generation; 3D registration; 3D matching; longitudinal analysis; precision; QUANTITATIVE COMPUTED-TOMOGRAPHY; TRABECULAR BONE MICROARCHITECTURE; IN-VIVO ASSESSMENT; STRENGTH; REPRODUCIBILITY; MICROSTRUCTURE; QUANTIFICATION; 1ST;
D O I
10.1016/j.jocd.2020.10.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The objective of this research was to develop 3D registration analysis method in longitudinal studies of high-resolution peripheral quantitative computed tomography (HR-pQCT), to analyze ranges of bone microstructure parameters in addition to standard parameters, and to test the precision of these measurements. Methods: Scans of HR-pQCT and analysis of bone microstructure were performed at 3 times in 15 subjects. The 3 images were matched 3-dimensionally, and bone microstructures were analyzed in the common region. In addition to standard measurement parameters of geometry, bone mineral density (BMD), trabecular bone, and cortical bone, parameters showing plate to rod-like structure, connectivity, cavity formation of trabecular bone, and bending stability of cortical bone were also measured. Precision was evaluated with the root mean square percent coefficient variance (RMS%CV). Results: RMS%CV was 0.1%-1.3% for geometry, 0.6%-1.9% for BMD, 0.8%-3.3% for trabecular bone, 2.1%-9.8% for additionally measured trabecular bone, 1.0%-3.4% for cortical bone excluding Ct.Po, 6.0%-6.1% for Ct.Po, and 0.8%-1.5% for additionally measured cortical bone. Precision was higher for 3D registration than for 2D registration in geometry, BV/ TV, and Ct.Po. Conclusions: 3D registration analysis of a range of bone microstructural parameters in longitudinal analysis of HR-pQCT showed good precision, offering potential for contributing to future research on osteoporosis and bone metabolic diseases.
引用
收藏
页码:319 / 329
页数:11
相关论文
共 30 条
  • [1] In vivo assessment of bone structure and estimated bone strength by first- and second-generation HR-pQCT
    Agarwal, S.
    Rosete, F.
    Zhang, C.
    McMahon, D. J.
    Guo, X. E.
    Shane, E.
    Nishiyama, K. K.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2016, 27 (10) : 2955 - 2966
  • [2] Measurement of Hip Geometry-Technical Background
    Beck, Thomas J.
    Broy, Susan B.
    [J]. JOURNAL OF CLINICAL DENSITOMETRY, 2015, 18 (03) : 331 - 337
  • [3] Operator variability in scan positioning is a major component of HR-pQCT precision error and is reduced by standardized training
    Bonaretti, S.
    Vilayphiou, N.
    Chan, C. M.
    Yu, A.
    Nishiyama, K.
    Liu, D.
    Boutroy, S.
    Ghasem-Zadeh, A.
    Boyd, S. K.
    Chapurlat, R.
    McKay, H.
    Shane, E.
    Bouxsein, M. L.
    Black, D. M.
    Majumdar, S.
    Orwoll, E. S.
    Lang, T. F.
    Khosla, S.
    Burghardt, A. J.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2017, 28 (01) : 245 - 257
  • [4] In vivo assessment of trabecular bone microarchitecture by high-resolution peripheral quantitative computed tomography
    Boutroy, S
    Bouxsein, ML
    Munoz, F
    Delmas, PD
    [J]. JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2005, 90 (12) : 6508 - 6515
  • [5] Guidelines for Assessment of Bone Microstructure in Rodents Using Micro-Computed Tomography
    Bouxsein, Mary L.
    Boyd, Stephen K.
    Christiansen, Blaine A.
    Guldberg, Robert E.
    Jepsen, Karl J.
    Mueller, Ralph
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2010, 25 (07) : 1468 - 1486
  • [6] Multicenter precision of cortical and trabecular bone quality measures assessed by high-resolution peripheral quantitative computed tomography
    Burghardt, Andrew J.
    Pialat, Jean-Baptiste
    Kazakia, Galateia J.
    Boutroy, Stephanie
    Engelke, Klaus
    Patsch, Janina M.
    Valentinitsch, Alexander
    Liu, Danmei
    Szabo, Eva
    Bogado, Cesar E.
    Belen Zanchetta, Maria
    McKay, Heather A.
    Shane, Elizabeth
    Boyd, Steven K.
    Bouxsein, Mary L.
    Chapurlat, Roland
    Khosla, Sundeep
    Majumdar, Sharmila
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2013, 28 (03) : 524 - 536
  • [7] High-resolution Computed Tomography for Clinical Imaging of Bone Microarchitecture
    Burghardt, Andrew J.
    Link, Thomas M.
    Majumdar, Sharmila
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (08) : 2179 - 2193
  • [8] High-Resolution Peripheral Quantitative Computed Tomography for the Assessment of Bone Strength and Structure: A Review by the Canadian Bone Strength Working Group
    Cheung, Angela M.
    Adachi, Jonathan D.
    Hanley, David A.
    Kendler, David L.
    Davison, K. Shawn
    Josse, Robert
    Brown, Jacques P.
    Ste-Marie, Louis-Georges
    Kremer, Richard
    Erlandson, Marta C.
    Dian, Larry
    Burghardt, Andrew J.
    Boyd, Steven K.
    [J]. CURRENT OSTEOPOROSIS REPORTS, 2013, 11 (02): : 136 - 146
  • [9] Precision of Second-Generation High-Resolution Peripheral Quantitative Computed Tomography: Intra- and Intertester Reproducibilities and Factors Involved in the Reproducibility of Cortical Porosity
    Chiba, Ko
    Okazaki, Narihiro
    Kurogi, Ayako
    Isobe, Yusaku
    Yonekura, Akihiko
    Tomita, Masato
    Osaki, Makoto
    [J]. JOURNAL OF CLINICAL DENSITOMETRY, 2018, 21 (02) : 295 - 302
  • [10] Reliability of HR-pQCT Derived Cortical Bone Structural Parameters When Using Uncorrected Instead of Corrected Automatically Generated Endocortical Contours in a Cross-Sectional Study: The Maastricht Study
    de Waard, Ellis A. C.
    Sarodnik, Cindy
    Pennings, Alexander
    de Jong, Joost J. A.
    Savelberg, Hans H. C. M.
    van Geel, Tineke A.
    van der Kallen, Carla J.
    Stehouwer, Coen D. A.
    Schram, Miranda T.
    Schaper, Nicolaas
    Dagnelie, Pieter C.
    Geusens, Piet P. M. M.
    Koster, Annemarie
    van Rietbergen, Bert
    van den Bergh, Joop P. W.
    [J]. CALCIFIED TISSUE INTERNATIONAL, 2018, 103 (03) : 252 - 265