Accommodation lags are higher in myopia than in emmetropia: Measurement methods and metrics matter

被引:28
作者
Kaphle, Dinesh [1 ,2 ]
Varnas, Saulius R. [3 ]
Schmid, Katrina L. [1 ]
Suheimat, Marwan [1 ]
Leube, Alexander [4 ]
Atchison, David A. [1 ]
机构
[1] Queensland Univ Technol, Ctr Vis & Eye Res, Brisbane, Qld, Australia
[2] Univ Canberra, Fac Hlth, Discipline Optometry, Canberra, ACT, Australia
[3] Carl Zeiss Vis Australia Holdings Ltd, Adelaide, SA, Australia
[4] Carl Zeiss Vis, Aalen, Germany
关键词
aberrometer; accommodation errors; autorefractor; emmetropia; metrics; myopia; ADULT MYOPES; IMAGE QUALITY; CONVERGENCE; REFRACTION; CHILDREN; STIMULUS; ABERRATION; LIMITS; MODEL; ONSET;
D O I
10.1111/opo.13021
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To determine whether accommodative errors in emmetropes and myopes are systematically different, and the effect of using different instruments and metrics. Methods Seventy-six adults aged 18-27 years comprising 24 emmetropes (spherical equivalent refraction of the dominant eye +0.04 +/- 0.03 D) and 52 myopes (-2.73 +/- 0.22 D) were included. Accommodation responses were measured with a Grand Seiko WAM-5500 and a Hartmann-Shack Complete Ophthalmic Analysis System aberrometer, using pupil plane (Zernike and Seidel refraction) and retinal image plane (neural sharpness-NS; and visual Strehl ratio for modulation transfer function-VSMTF) metrics at 40, 33 and 25 cm. Accommodation stimuli were presented to the corrected dominant eye, and responses, referenced to the corneal plane, were determined in the fellow eye. Linear mixed-effects models were used to determine influence of the refractive group, the measurement method, accommodation stimulus, age, race, parental myopia, gender and binocular measures of heterophoria, accommodative convergence/accommodation and convergence accommodation/convergence ratios. Results Lags of accommodation were affected significantly by the measurement method (p < 0.001), the refractive group (p = 0.003), near heterophoria (p = 0.002) and accommodative stimulus (p < 0.05), with significant interactions between some of these variables. Overall, emmetropes had smaller lags of accommodation than myopes with respective means +/- standard errors of 0.31 +/- 0.08 D and 0.61 +/- 0.06 D (p = 0.003). Lags were largest for the Grand Seiko and Zernike defocus, intermediate for NS and VSMTF, and least for Seidel defocus. Conclusions The mean lag of accommodation in emmetropes is approximately equal to the previously reported depth of focus. Myopes had larger (double) lags than emmetropes. Differences between methods and instruments could be as great as 0.50 D, and this must be considered when comparing studies and outcomes. Accommodative lag increased with the accommodation stimulus, but only for methods using a fixed small pupil diameter.
引用
收藏
页码:1103 / 1114
页数:12
相关论文
共 52 条
[1]  
Abbott ML, 1998, OPHTHAL PHYSL OPT, V18, P13, DOI 10.1016/S0275-5408(97)00072-0
[2]   Amplitude of Accommodation in Type 1 Diabetes [J].
Adnan ;
Efron, Nathan ;
Mathur, Ankit ;
Edwards, Katie ;
Pritchard, Nicola ;
Suheimat, Marwan ;
Atchison, David A. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (10) :7014-7018
[3]   Experimental investigation of accommodation in eyes fit with multifocal contact lenses using a clinical auto-refractor [J].
Altoaimi, Basal H. ;
Kollbaum, Pete ;
Meyer, Dawn ;
Bradley, Arthur .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2018, 38 (02) :152-163
[4]   Noticeable, troublesome and objectionable limits of blur [J].
Atchison, DA ;
Fisher, SW ;
Pedersen, CA ;
Ridall, PG .
VISION RESEARCH, 2005, 45 (15) :1967-1974
[5]   The use of autorefractors using the image-size principle in determining on-axis and off-axis refraction. Part 2: Theoretical study of peripheral refraction with the Grand Seiko AutoRef/Keratometer WAM-5500 [J].
Atchison, David A. ;
Suheimat, Marwan ;
Zacharovas, Stanislovas ;
Campbell, Charles E. .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2022, 42 (02) :293-300
[6]   Accommodation stimulus and response determinations with autorefractors [J].
Atchison, David A. ;
Varnas, Saulius R. .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2017, 37 (01) :96-104
[7]   Limits of spherical blur determined with an adaptive optics mirror [J].
Atchison, David A. ;
Guo, Huanqing ;
Fisher, Scott W. .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2009, 29 (03) :300-311
[8]  
Bakaraju Ravi C, 2015, J Optom, V8, P206, DOI 10.1016/j.optom.2015.01.005
[9]   Sources of error in clinical measurement of the amplitude of accommodation [J].
Burns, David H. ;
Atten, Peter M. ;
Edgar, David F. ;
Evans, Bruce J. W. .
JOURNAL OF OPTOMETRY, 2020, 13 (01) :3-14
[10]   The use of autorefractors using the image-size principle in determining on-axis and off-axis refraction. Part 1: Analysis of optical principles of autorefractors [J].
Campbell, Charles E. ;
Suheimat, Marwan ;
Zacharovas, Stanislovas ;
Atchison, David A. .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2022, 42 (02) :283-292