Calibration and correction of laser-induced incandescence for soot volume fraction measurements

被引:1
|
作者
Choi, MY [1 ]
Jensen, KA [1 ]
机构
[1] Univ Illinois, Dept Mech Engn, Chicago, IL 60607 USA
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
A procedure for accurately calibrating and correcting the projected laser-induced incandescence (LII) intensity measurements for axisymmetric flames is presented. The corrected LII intensity and soot volume fractions along the measurement axis (which are unknowns) are calculated using the projected LII distribution. This technique does not require calibration using an independent measurement of soot volume fraction. Instead, a single line-of-sight extinction measurement is needed to obtain the calibration factor and corrections for the projected LII intensities. This technique is demonstrated to provide accurate soot concentrations for mediums producing significant trapping of the LII signal. (C) 1998 by The Combustion Institute.
引用
收藏
页码:485 / 491
页数:7
相关论文
共 50 条
  • [21] Soot volume fraction measurements in aero-engine exhausts using extinction-calibrated backward laser-induced incandescence
    Delhay, J.
    Desgroux, P.
    Therssen, E.
    Bladh, H.
    Bengtsson, P. -E.
    Hoenen, H.
    Black, J. D.
    Vallet, I.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2009, 95 (04): : 825 - 838
  • [22] Improvement in soot concentration measurements by laser-induced incandescence (LII) through a particle size correction
    Reimann, J.
    Kuhlmann, S. -A.
    Will, S.
    COMBUSTION AND FLAME, 2008, 153 (04) : 650 - 654
  • [23] Quantifying uncertainty in soot volume fraction estimates using Bayesian inference of auto-correlated laser-induced incandescence measurements
    Hadwin, Paul J.
    Sipkens, T. A.
    Thomson, K. A.
    Liu, F.
    Daun, K. J.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2016, 122 (01):
  • [24] Quantifying uncertainty in soot volume fraction estimates using Bayesian inference of auto-correlated laser-induced incandescence measurements
    Paul J. Hadwin
    T. A. Sipkens
    K. A. Thomson
    F. Liu
    K. J. Daun
    Applied Physics B, 2016, 122
  • [25] TWO-DIMENSIONAL IMAGING OF SOOT VOLUME FRACTION IN PULSED DIFFUSION FLAMES BY LASER-INDUCED INCANDESCENCE
    Sapmaz, H.
    Ghenai, C.
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER CONFERENCE, VOL 1, PTS A AND B, 2006, : 1405 - 1409
  • [26] Soot measurements in a simulated engine exhaust using laser-induced incandescence
    Wainner, RT
    Seitzman, JM
    Martin, SR
    AIAA JOURNAL, 1999, 37 (06) : 738 - 743
  • [27] Analysis of calibration techniques for laser-induced incandescence measurements in flames
    Pastor, J. V.
    Garcia, J. M.
    Pastor, J. M.
    Buitrago, J. E.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (12) : 3279 - 3288
  • [28] Two-color laser-induced incandescence (2C-LII) technique for absolute soot volume fraction measurements in flames
    De Luliis, S
    Cignoli, F
    Zizak, G
    APPLIED OPTICS, 2005, 44 (34) : 7414 - 7423
  • [29] Soot volume fraction measurements in aero-engine model combustor outlet using two-color laser-induced incandescence
    Wang, Linsen
    Ding, Pengji
    Yan, Sijie
    Li, Jie
    Zhang, Jingwei
    Wang, Chaozong
    Cao, Zhibo
    Zhou, Quan
    Mu, Jinhe
    Meng, Gang
    Song, Wenyan
    Xu, Zhenyu
    Yan, Bo
    Chen, Shuang
    CHINESE JOURNAL OF AERONAUTICS, 2025, 38 (03)
  • [30] Anomalies in picosecond laser-induced incandescence of soot
    Michelsen, Hope A.