Calibration and correction of laser-induced incandescence for soot volume fraction measurements

被引:1
|
作者
Choi, MY [1 ]
Jensen, KA [1 ]
机构
[1] Univ Illinois, Dept Mech Engn, Chicago, IL 60607 USA
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
A procedure for accurately calibrating and correcting the projected laser-induced incandescence (LII) intensity measurements for axisymmetric flames is presented. The corrected LII intensity and soot volume fractions along the measurement axis (which are unknowns) are calculated using the projected LII distribution. This technique does not require calibration using an independent measurement of soot volume fraction. Instead, a single line-of-sight extinction measurement is needed to obtain the calibration factor and corrections for the projected LII intensities. This technique is demonstrated to provide accurate soot concentrations for mediums producing significant trapping of the LII signal. (C) 1998 by The Combustion Institute.
引用
收藏
页码:485 / 491
页数:7
相关论文
共 50 条
  • [1] Soot volume fraction and particle size measurements with laser-induced incandescence
    Mewes, B
    Seitzman, JM
    APPLIED OPTICS, 1997, 36 (03): : 709 - 717
  • [2] Absorption correction of two-color laser-induced incandescence signals for soot volume fraction measurements
    Migliorini, Francesca
    De Iuliis, Silvana
    Cignoli, Francesco
    Zizak, Giorgio
    APPLIED OPTICS, 2006, 45 (29) : 7706 - 7711
  • [3] Laser-induced incandescence for soot particle size and volume fraction measurements using on-line extinction calibration
    Axelsson, B
    Collin, R
    Bengtsson, PE
    APPLIED PHYSICS B-LASERS AND OPTICS, 2001, 72 (03): : 367 - 372
  • [4] Laser-induced incandescence for soot particle size and volume fraction measurements using on-line extinction calibration
    B. Axelsson
    R. Collin
    P.E. Bengtsson
    Applied Physics B, 2001, 72 : 367 - 372
  • [5] SPATIALLY-RESOLVED MEASUREMENTS OF SOOT VOLUME FRACTION USING LASER-INDUCED INCANDESCENCE
    QUAY, B
    LEE, TW
    NI, T
    SANTORO, RJ
    COMBUSTION AND FLAME, 1994, 97 (3-4) : 384 - 392
  • [6] Measurements of soot volume fraction in pulsed diffusion flame by laser induced incandescence
    Sapmaz, Hayri
    Lin, Cheng-Xian
    Ghenai, Chaouki
    EXPERIMENTS IN FLUIDS, 2008, 44 (01) : 137 - 144
  • [7] Measurements of soot volume fraction in pulsed diffusion flame by laser induced incandescence
    Hayri Sapmaz
    Cheng-Xian Lin
    Chaouki Ghenai
    Experiments in Fluids, 2008, 44 : 137 - 144
  • [8] Cavity ringdown and laser-induced incandescence measurements of soot
    Vander Wal, RL
    Ticich, TM
    APPLIED OPTICS, 1999, 38 (09) : 1444 - 1451
  • [9] Peak soot temperature in laser-induced incandescence measurements
    S. De Iuliis
    F. Migliorini
    F. Cignoli
    G. Zizak
    Applied Physics B, 2006, 83 : 397 - 402
  • [10] LASER-INDUCED INCANDESCENCE - DEVELOPMENT AND CHARACTERIZATION TOWARDS A MEASUREMENT OF SOOT-VOLUME FRACTION
    VANDERWAL, RL
    WEILAND, KJ
    APPLIED PHYSICS B-LASERS AND OPTICS, 1994, 59 (04): : 445 - 452