Electrochemical sensor based on phospholipid modified glassy carbon electrode - determination of paraquat

被引:28
|
作者
Tomkova, H. [1 ]
Sokolova, R. [2 ]
Opletal, T. [1 ]
Kucerova, P. [1 ]
Kucera, L. [1 ]
Souckova, J. [1 ]
Skopalova, J. [1 ]
Bartak, P. [1 ]
机构
[1] Palacky Univ, Reg Ctr Adv Technol & Mat, Dept Analyt Chem, Fac Sci, 17 Listopadu 12, Olomouc 77146, Czech Republic
[2] Czech Acad Sci, J Heyrovsky Inst Phys Chem, Dolejskova 2155-3, Prague 18223 8, Czech Republic
关键词
Asolectin; Phospholipid; Paraquat; Sensor; Square wave voltammetry; BILAYER-LIPID MEMBRANES; WAVE VOLTAMMETRIC DETERMINATION; PERFORMANCE LIQUID-CHROMATOGRAPHY; ATOMIC-FORCE MICROSCOPY; DOPED DIAMOND ELECTRODE; PASTE ELECTRODE; MASS-SPECTROMETRY; SENSITIVE DETERMINATION; STRIPPING VOLTAMMETRY; CYCLIC VOLTAMMETRY;
D O I
10.1016/j.jelechem.2017.12.048
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrochemical sensor based on glassy carbon electrode modified with asolectin (mixture of soybean phospholipids) was developed. Properties of phospholipid layer, such as thickness and compactness, were investigated using atomic force microscopy and X-ray photoelectron spectroscopy. Phospholipids completely cover whole surface and the thickness of the layer 7.1 +/- 1.2 nm corresponds to the value of the phospholipid bilayer of cell membranes. Due to the accumulation of paraquat in the phospholipid layer, square wave voltammetry with asolectin modified electrode exhibits three times higher sensitivity, measured as a slope of calibration dependence, and better linearity in comparison to unmodified glassy carbon electrode. Limit of detection 2.2 nmol L-1 and recoveries higher than 88% were achieved in model samples of water. The method was used for determination of paraquat in real sample of river water and results were compared with high performance liquid chromatography and differential pulse voltammetry on hanging mercury drop electrode giving 0.071 +/- 0.010, 0.050 +/- 0.010 and 0.061 +/- 0.008 mu mol L-1, respectively.
引用
收藏
页码:33 / 39
页数:7
相关论文
共 50 条
  • [31] The Determination of Dopamine Using Glassy Carbon Electrode Pretreated by a Simple Electrochemical Method
    Huang, De-Qian
    Chen, Cheng
    Wu, Yi-Ming
    Zhang, Hong
    Sheng, Liang-Quan
    Xu, Hua-Jie
    Liu, Zhao-Di
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (06): : 5510 - 5520
  • [32] A Triple Electrochemical Platform for Simultaneous Determination of Isoproterenol, Acetaminophen and Tyrosine Based on a Glassy Carbon Electrode Modified with Hematoxylin and Graphene
    Beitollahi, Hadi
    Salimi, Hadiseh
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2016, 163 (14) : H1157 - H1164
  • [33] Optimization of an Electrochemical Sensor for Determination of Imidacloprid Based on -cyclodextrin Electropolymerization on Glassy Carbon Electrode
    Ferreira Oliveira, Ana Elisa
    Bettio, Guilherme Braga
    Pereira, Arnaldo Cesar
    ELECTROANALYSIS, 2018, 30 (09) : 1929 - 1937
  • [34] Selective and Sensitive Nitrite Sensor Based on Glassy Carbon Electrode Modified by Silver Nanochains
    Shaikh, Tayyaba
    Ibupoto, Zaffar Hussain
    Talpur, Farah N.
    Sirajuddin
    Khaskheli, Abdul Rauf
    Agheem, Muhammad H.
    Siddiqui, Samia
    Tahira, Aneela
    Willander, Magnus
    Yu, Cong
    ELECTROANALYSIS, 2017, 29 (02) : 415 - 422
  • [35] Electrochemical oxidative determination of 4-nitrophenol based on a glassy carbon electrode modified with a hydroxyapatite nanopowder
    Yin, Huanshun
    Zhou, Yunlei
    Ai, Shiyun
    Liu, Xianggang
    Zhu, Lusheng
    Lu, Linan
    MICROCHIMICA ACTA, 2010, 169 (1-2) : 87 - 92
  • [36] Electrochemical Determination of Bisphenol A Based on Poly(Chromotropic Acid) Modified Glassy Carbon Electrode
    Filik, Hayati
    Avan, Asiye Aslihan
    CURRENT ANALYTICAL CHEMISTRY, 2017, 13 (06) : 464 - 473
  • [37] Electrochemical Determination of Chloramphenicol based on ZnO-NPs/SWCNTS Composite modified glassy carbon electrode
    Wang, Wei
    Sun, De
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (02): : 1 - 13
  • [38] Electrochemical Determination of 4-Nonylphenol Based on Graphene-Chitosan Modified Glassy Carbon Electrode
    Zhou Wen-Shu
    Zhao Bo
    Huang Xiao-Hua
    Yang Xiao-Di
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (05) : 675 - 680
  • [39] Electrochemical determination of morphine at ordered mesoporous carbon modified glassy carbon electrode
    Li, Fei
    Song, Jixia
    Shan, Changsheng
    Gao, Dongmei
    Xu, Xiaoyu
    Niu, Li
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (06): : 1408 - 1413
  • [40] An electrochemical sensor for the determination of tartrazine based on CHIT/GO/MWCNTs/AuNPs composite film modified glassy carbon electrode
    Rovina, Kobun
    Siddiquee, Shafiquzzaman
    Md Shaarani, Sharifudin
    DRUG AND CHEMICAL TOXICOLOGY, 2021, 44 (05) : 447 - 457