Electrochemical sensor based on phospholipid modified glassy carbon electrode - determination of paraquat

被引:28
|
作者
Tomkova, H. [1 ]
Sokolova, R. [2 ]
Opletal, T. [1 ]
Kucerova, P. [1 ]
Kucera, L. [1 ]
Souckova, J. [1 ]
Skopalova, J. [1 ]
Bartak, P. [1 ]
机构
[1] Palacky Univ, Reg Ctr Adv Technol & Mat, Dept Analyt Chem, Fac Sci, 17 Listopadu 12, Olomouc 77146, Czech Republic
[2] Czech Acad Sci, J Heyrovsky Inst Phys Chem, Dolejskova 2155-3, Prague 18223 8, Czech Republic
关键词
Asolectin; Phospholipid; Paraquat; Sensor; Square wave voltammetry; BILAYER-LIPID MEMBRANES; WAVE VOLTAMMETRIC DETERMINATION; PERFORMANCE LIQUID-CHROMATOGRAPHY; ATOMIC-FORCE MICROSCOPY; DOPED DIAMOND ELECTRODE; PASTE ELECTRODE; MASS-SPECTROMETRY; SENSITIVE DETERMINATION; STRIPPING VOLTAMMETRY; CYCLIC VOLTAMMETRY;
D O I
10.1016/j.jelechem.2017.12.048
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrochemical sensor based on glassy carbon electrode modified with asolectin (mixture of soybean phospholipids) was developed. Properties of phospholipid layer, such as thickness and compactness, were investigated using atomic force microscopy and X-ray photoelectron spectroscopy. Phospholipids completely cover whole surface and the thickness of the layer 7.1 +/- 1.2 nm corresponds to the value of the phospholipid bilayer of cell membranes. Due to the accumulation of paraquat in the phospholipid layer, square wave voltammetry with asolectin modified electrode exhibits three times higher sensitivity, measured as a slope of calibration dependence, and better linearity in comparison to unmodified glassy carbon electrode. Limit of detection 2.2 nmol L-1 and recoveries higher than 88% were achieved in model samples of water. The method was used for determination of paraquat in real sample of river water and results were compared with high performance liquid chromatography and differential pulse voltammetry on hanging mercury drop electrode giving 0.071 +/- 0.010, 0.050 +/- 0.010 and 0.061 +/- 0.008 mu mol L-1, respectively.
引用
收藏
页码:33 / 39
页数:7
相关论文
共 50 条
  • [21] A Novel Sensitive Electrochemical Sensor Based on Nickel Chloride Solution Modified Glassy Carbon Electrode for Curcumin Determination
    Zokhtareh, Rosan
    Rahimnejad, Mostafa
    ELECTROANALYSIS, 2018, 30 (05) : 921 - 927
  • [22] Sensor based on Copper Nanoparticles Modified Electrochemically Activated Glassy Carbon Electrode for Paracetamol Determination
    Kassem, Mohammed A.
    Awad, Mohamed, I
    Morad, Moataz
    Aljandali, B. A.
    Pashameah, Rami Adel
    Alessa, Hussain
    Mohammed, G., I
    Sayqal, Ali
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (04):
  • [23] Electrochemical determination of Sudan I in food samples at graphene modified glassy carbon electrode based on the enhancement effect of sodium dodecyl sulphonate
    Ma, Xinying
    Chao, Mingyong
    Wang, Zhaoxia
    FOOD CHEMISTRY, 2013, 138 (2-3) : 739 - 744
  • [24] Carbon Paste Electrode Modified with Biochar for Sensitive Electrochemical Determination of Paraquat
    Kalinke, Cristiane
    Mangrich, Antonio S.
    Marcolino-Junior, Luiz H.
    Bergamini, Marcio F.
    ELECTROANALYSIS, 2016, 28 (04) : 764 - 769
  • [25] Electrochemical Determination of Amoxicillin on a Poly(Acridine Orange) Modified Glassy Carbon Electrode
    Agin, Fatma
    ANALYTICAL LETTERS, 2016, 49 (09) : 1366 - 1378
  • [26] Electrochemical behavior of Co(II) polymer-modified glassy carbon electrode for the determination of dopamine
    Vladislavic, Nives
    Roncevic, Ivana Skugor
    Buzuk, Marijo
    Dugec, Josipa
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2024, 28 (11) : 4311 - 4323
  • [27] Electrochemical determination of ajmalicine using glassy carbon electrode modified with gold nanoparticles
    Mehmeti, Eda
    Stankovic, Dalibor M.
    Chaiyo, Sudkate
    Svorc, L'ubomir
    Ortner, Astrid
    Kalcher, Kurt
    MONATSHEFTE FUR CHEMIE, 2016, 147 (07): : 1161 - 1166
  • [28] Glassy carbon electrode modified with carbon black and cross-linked alginate film: a new voltammetric electrode for paraquat determination
    Pacheco, Milena Rafalski
    Barbosa, Sergiane Caldas
    Neves Quadrado, Rafael Fonseca
    Fajardo, Andre Ricardo
    Dias, Daiane
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (15) : 3269 - 3280
  • [29] Electrochemical Sensor for Caffeine Based on a Glassy Carbon Electrode Modified with an Attapulgite/Nafion Film
    Tajeu, Kevin Yemele
    Ymele, Ervice
    Jiokeng, Sherman Lesly Zambou
    Tonle, Ignas Kenfack
    ELECTROANALYSIS, 2019, 31 (02) : 350 - 356
  • [30] MWCNT-CTAB modified glassy carbon electrode as a sensor for the determination of paracetamol
    Gowda, Jayant I.
    Gunjiganvi, Danavva G.
    Sunagar, Nagaveni B.
    Bhat, Manjushree N.
    Nandibewoor, Sharanappa T.
    RSC ADVANCES, 2015, 5 (61): : 49045 - 49053