Evaluation of a prototype 3D ultrasound system for multimodality imaging of cervical nodes for adaptive radiation therapy

被引:1
作者
Fraser, Danielle [1 ]
Fava, Palma [2 ]
Cury, Fabio [2 ]
Vuong, Te [2 ]
Falco, Tony [3 ]
Verhaegen, Frank [1 ]
机构
[1] McGill Univ, Montreal, PQ, Canada
[2] Montreal Gen Hosp, Radiat Oncol, Montreal, PQ, Canada
[3] Resonant Med, Montreal, PQ, Canada
来源
MEDICAL IMAGING 2007: VISUALIZATION AND IMAGE-GUIDED PROCEDURES, PTS 1 AND 2 | 2007年 / 6509卷
关键词
image-guidance; ultrasound; 3D; localization; multimodality; registration; radiation therapy; segmentation; visualization;
D O I
10.1117/12.709299
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Sonography has good topographic accuracy for superficial lymph node assessment in patients with head and neck cancers.' It is therefore an ideal non-invasive tool for precise inter-fraction volumetric analysis of enlarged cervical nodes. In addition, when registered with computed tomography (CT) images, ultrasound information may improve target volume delineation and facilitate image-guided adaptive radiation therapy. A feasibility study was developed to evaluate the use of a prototype ultrasound system capable of three dimensional visualization and multi-modality image fusion for cervical node geometry. A ceiling-mounted optical tracking camera recorded the position and orientation of a transducer in order to synchronize the transducer's position with respect to the room's coordinate system. Tracking systems were installed in both the CT-simulator and radiation therapy treatment rooms. Serial images were collected at the time of treatment planning and at subsequent treatment fractions. Volume reconstruction was performed by generating surfaces around contours. The quality of the spatial reconstruction and semi-automatic segmentation was highly dependent on the system's ability to track the transducer throughout each scan procedure. The ultrasound information provided enhanced soft tissue contrast and facilitated node delineation. Manual segmentation was the preferred method to contour structures due to their sonographic topography.
引用
收藏
页数:8
相关论文
共 14 条
  • [1] A REVIEW OF ELECTRONIC PORTAL IMAGING DEVICES (EPIDS)
    BOYER, AL
    ANTONUK, L
    FENSTER, A
    VANHERK, M
    MEERTENS, H
    MUNRO, P
    REINSTEIN, LE
    WONG, J
    [J]. MEDICAL PHYSICS, 1992, 19 (01) : 1 - 16
  • [2] Bruneton JN, 2002, MED RAD DIA IMG, P137
  • [3] Intra-subject elastic registration of 3D ultrasound images
    Foroughi, Pezhman
    Abolmaesumi, Purang
    Hashtrudi-Zaad, Keyvan
    [J]. MEDICAL IMAGE ANALYSIS, 2006, 10 (05) : 713 - 725
  • [4] A comparison of CT scan to transrectal ultrasound-measured prostate volume in untreated prostate cancer
    Hoffelt, SC
    Marshall, LM
    Garzotto, M
    Hung, A
    Holland, J
    Beer, TM
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 57 (01): : 29 - 32
  • [5] X-RAY SCATTER IN MEGAVOLTAGE TRANSMISSION RADIOGRAPHY - PHYSICAL CHARACTERISTICS AND INFLUENCE ON IMAGE QUALITY
    JAFFRAY, DA
    BATTISTA, JJ
    FENSTER, A
    MUNRO, P
    [J]. MEDICAL PHYSICS, 1994, 21 (01) : 45 - 60
  • [6] Prostate volume determination:: Differential volume measurements comparing CT and TRUS
    Kalkner, Karl Mikael
    Kubicek, Gregory
    Nilsson, Josef
    Lundell, Marie
    Levitt, Seymour
    Nilsson, Sten
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 (02) : 179 - 183
  • [7] A comparison of daily CT localization to a daily ultrasound-based system in prostate cancer
    Lattanzi, J
    McNeeley, S
    Pinover, W
    Horwitz, E
    Das, I
    Schultheiss, TE
    Hanks, GE
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (04): : 719 - 725
  • [8] Use of portal images and bat ultrasonography to measure setup error and organ motion for prostate IMRT: Implications for treatment margins
    Little, DJ
    Dong, L
    Levy, LB
    Chandra, A
    Kuban, DA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (05): : 1218 - 1224
  • [9] A comparison of CT- and ultrasound-based imaging to localize the prostate for external beam radiotherapy
    McNair, HA
    Mangar, SA
    Coffey, J
    Shoulders, B
    Hansen, VN
    Norman, A
    Staffurth, J
    Sohaib, SA
    Warrington, AP
    Dearnaley, DP
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (03): : 678 - 687
  • [10] Impact of differences in ultrasound and computed tomography volumes on treatment planning of permanent prostate implants
    Narayana, V
    Roberson, PL
    Pu, AT
    Sandler, H
    Winfield, RH
    McLaughlin, PW
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (05): : 1181 - 1185