Can the IVIM model be used for renal perfusion imaging?

被引:50
作者
Müller, MF [1 ]
Prasad, PV [1 ]
Edelman, RR [1 ]
机构
[1] Univ Bern, Inselspital, Dept Radiol, CH-3010 Bern, Switzerland
关键词
intravoxel incoherent motion; magnetic resonance imaging; kidney; perfusion; kidney diffusion;
D O I
10.1016/S0720-048X(97)01161-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Renal perfusion imaging may provide information about the hemodynamic significance of a renal artery stenosis and could improve noninvasive characterization when combined with angiography. It was proposed previously that diffusion sequences could provide useful perfusion indices based on the intravoxel incoherent motion (IVIM) model. Owing to motion artifacts, diffusion imaging has been restricted to relatively immobile organs like the brain. With the availability of single-shot echo-planar imaging (EPI) our purpose was to evaluate the IVIM model in renal perfusion. Methods and material: Eight volunteers underwent diffusion-sensitive magnetic resonance (MR) imaging of the kidneys using a spin echo (SE) EPI sequence. The diffusion coefficients determined by a linear regression analysis and fits to the IVIM function were calculated. Results and conclusion: Our preliminary experience does not support the possibility of obtaining perfusion information using the IVIM model in the kidneys. (C) 1998 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:297 / 303
页数:7
相关论文
共 56 条
[1]   THE EFFECTS OF RANDOM DIRECTIONAL DISTRIBUTED FLOW IN NUCLEAR-MAGNETIC-RESONANCE IMAGING [J].
AHN, CB ;
LEE, SY ;
NALCIOGLU, O ;
CHO, ZH .
MEDICAL PHYSICS, 1987, 14 (01) :43-48
[2]   CAPTOPRIL AND RENAL AUTO-REGULATION [J].
BLYTHE, WB .
NEW ENGLAND JOURNAL OF MEDICINE, 1983, 308 (07) :390-391
[3]  
Bookstein J J, 1966, Invest Radiol, V1, P281, DOI 10.1097/00004424-196607000-00018
[4]   DIGITAL SUBTRACTION ANGIOGRAPHY OF THE ABDOMINAL-AORTA AND RENAL-ARTERIES - COMPARISON WITH CONVENTIONAL AORTOGRAPHY [J].
BUONOCORE, E ;
MEANEY, TF ;
BORKOWSKI, GP ;
PAVLICEK, W ;
GALLAGHER, J .
RADIOLOGY, 1981, 139 (02) :281-286
[5]   EFFECTS OF DIFFUSION ON FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE EXPERIMENTS [J].
CARR, HY ;
PURCELL, EM .
PHYSICAL REVIEW, 1954, 94 (03) :630-638
[6]  
DATSERIS IE, 1994, J NUCL MED, V35, P251
[7]   RENAL-ARTERY BLOOD-FLOW - QUANTITATION WITH PHASE-CONTRAST MR-IMAGING WITH AND WITHOUT BREATH-HOLDING [J].
DEBATIN, JF ;
TING, RH ;
WEGMULLER, H ;
SOMMER, FG ;
FREDRICKSON, JO ;
BROSNAN, TJ ;
BOWMAN, BS ;
MYERS, BD ;
HERFKENS, RJ ;
PELC, NJ .
RADIOLOGY, 1994, 190 (02) :371-378
[8]   IMAGING OF THE RENAL-ARTERIES - VALUE OF MR ANGIOGRAPHY [J].
DEBATIN, JF ;
SPRITZER, CE ;
GRIST, TM ;
BEAM, C ;
SVETKEY, LP ;
NEWMAN, GE ;
SOSTMAN, HD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (05) :981-990
[9]  
DOLLERY CT, 1985, CECIL TXB MED, V1, P266
[10]   INTRAVENOUS DIGITAL SUBTRACTION RENAL ANGIOGRAPHY - USE IN SCREENING FOR RENOVASCULAR HYPERTENSION [J].
DUNNICK, NR ;
SVETKEY, LP ;
COHAN, RH ;
NEWMAN, GE ;
BRAUN, SD ;
HIMMELSTEIN, SI ;
BOLLINGER, RR ;
MCCANN, RL ;
WILKINSON, RH ;
KLOTMAN, PE .
RADIOLOGY, 1989, 171 (01) :219-222