Type-2 Fuzzy Logic Controlled Three-level Shunt Active Power Filter for Power Quality Improvement

被引:11
作者
Suresh, Dhanavath [1 ]
Singh, Saijan Pal [1 ]
机构
[1] Indian Inst Technol Roorkee, Dept Elect Engn, Roorkee 247667, Uttar Pradesh, India
关键词
active power filter; harmonics; multi-level inverter; PI controller; reactive power; type-2 fuzzy logic controller; type-1 fuzzy logic controller; power quality; MULTILEVEL INVERTER; SIMULATION;
D O I
10.1080/15325008.2016.1138158
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article proposes a three-level shunt active power filter for power quality improvement using a type-2 fuzzy logic controller (T2FLC). The reference compensating current is extracted using the P-Q theory. The majority of works previously reported are based on two-level inverters with a conventional Proportional integral (PI) controller, which requires rigorous mathematical modeling of the system. In this paper, a T2FLC controlled three-level active power filter is proposed to overcome the problem associated with PI controller. The T2FLC algorithm is applied for controlling the DC-side capacitor voltage as well as the harmonic currents of the three-level active power filter. The active power filter with a T2FLC is simulated in MATLAB Simulink environment (The Math Works, Natick, Massachusetts, USA). The simulated response shows that the proposed shunt active power filter controller has produced a sinusoidal supply current with low harmonic distortion and in phase with the source voltage. To verify the simulated response, a prototype model of inverter has been developed, and the control pulses for the active power filter are generated using a dSPACE1104 (dSPACE GmbH, Paderborn, Germany) controller. The experimental results demonstrate that the T2FLC greatly improves the transient performance of the three-level active power filter.
引用
收藏
页码:873 / 882
页数:10
相关论文
共 24 条
[11]   Type-2 fuzzy logic systems [J].
Karnik, NN ;
Mendel, JM ;
Liang, QL .
IEEE TRANSACTIONS ON FUZZY SYSTEMS, 1999, 7 (06) :643-658
[12]   Soft Computing Techniques for the Control of an Active Power Filter [J].
Kumar, Parmod ;
Mahajan, Alka .
IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (01) :452-461
[13]   APPLICATION OF FUZZY LOGIC TO APPROXIMATE REASONING USING LINGUISTIC-SYNTHESIS [J].
MAMDANI, EH .
IEEE TRANSACTIONS ON COMPUTERS, 1977, 26 (12) :1182-1191
[14]   Type-2 fuzzy sets and systems: An overview [J].
Mendel, Jerry M. .
IEEE COMPUTATIONAL INTELLIGENCE MAGAZINE, 2007, 2 (01) :20-29
[15]   A comparative study of harmonic currents extraction by simulation and implementation [J].
Merabet, L. ;
Saad, S. ;
Abdeslam, D. Ould ;
Omeiri, A. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2013, 53 :507-514
[16]   Types-1 and-2 fuzzy logic controllers-based shunt active filter Id-Iq control strategy with different fuzzy membership functions for power quality improvement using RTDS hardware [J].
Mikkili, Suresh ;
Panda, Anup Kumar .
IET POWER ELECTRONICS, 2013, 6 (04) :818-833
[17]   Robust Model-Following control of a three-level Neutral Point Clamped shunt active filter in the medium voltage range [J].
Munduate, Alejandro ;
Figueres, Emilio ;
Garcera, Gabriel .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2009, 31 (10) :577-588
[18]   Harmonic optimization of multilevel converters using genetic algorithms [J].
Ozpineci, Burak ;
Tolbert, Leon M. ;
Chiasson, John N. .
IEEE Power Electronics Letters, 2005, 3 (03) :92-95
[19]   Modeling and simulation of three phase multilevel inverter for grid connected photovoltaic systems [J].
Ravi, A. ;
Manoharan, P. S. ;
Anand, J. Vijay .
SOLAR ENERGY, 2011, 85 (11) :2811-2818
[20]   Fuzzy logic controller for three-level shunt active filter compensating harmonics and reactive power [J].
Saad, S. ;
Zellouma, L. .
ELECTRIC POWER SYSTEMS RESEARCH, 2009, 79 (10) :1337-1341