Type-2 Fuzzy Logic Controlled Three-level Shunt Active Power Filter for Power Quality Improvement

被引:11
作者
Suresh, Dhanavath [1 ]
Singh, Saijan Pal [1 ]
机构
[1] Indian Inst Technol Roorkee, Dept Elect Engn, Roorkee 247667, Uttar Pradesh, India
关键词
active power filter; harmonics; multi-level inverter; PI controller; reactive power; type-2 fuzzy logic controller; type-1 fuzzy logic controller; power quality; MULTILEVEL INVERTER; SIMULATION;
D O I
10.1080/15325008.2016.1138158
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article proposes a three-level shunt active power filter for power quality improvement using a type-2 fuzzy logic controller (T2FLC). The reference compensating current is extracted using the P-Q theory. The majority of works previously reported are based on two-level inverters with a conventional Proportional integral (PI) controller, which requires rigorous mathematical modeling of the system. In this paper, a T2FLC controlled three-level active power filter is proposed to overcome the problem associated with PI controller. The T2FLC algorithm is applied for controlling the DC-side capacitor voltage as well as the harmonic currents of the three-level active power filter. The active power filter with a T2FLC is simulated in MATLAB Simulink environment (The Math Works, Natick, Massachusetts, USA). The simulated response shows that the proposed shunt active power filter controller has produced a sinusoidal supply current with low harmonic distortion and in phase with the source voltage. To verify the simulated response, a prototype model of inverter has been developed, and the control pulses for the active power filter are generated using a dSPACE1104 (dSPACE GmbH, Paderborn, Germany) controller. The experimental results demonstrate that the T2FLC greatly improves the transient performance of the three-level active power filter.
引用
收藏
页码:873 / 882
页数:10
相关论文
共 24 条
[1]   INSTANTANEOUS REACTIVE POWER COMPENSATORS COMPRISING SWITCHING DEVICES WITHOUT ENERGY-STORAGE COMPONENTS [J].
AKAGI, H ;
KANAZAWA, Y ;
NABAE, A .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1984, 20 (03) :625-630
[2]   Control of Cascade Multilevel Inverter Using Fuzzy Logic Technique [J].
Alabbasi, Rabee' H. ;
Salih, Shafaa M. .
IEEE PEDG 2010: THE 2ND INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS, 2010, :96-101
[3]   A control structure for fast harmonics compensation in active filters [J].
Allmeling, J .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2004, 19 (02) :508-514
[4]   dSPACE based adaptive neuro-fuzzy controller of grid interactive inverter [J].
Altin, Necmi ;
Sefa, Ibrahim .
ENERGY CONVERSION AND MANAGEMENT, 2012, 56 :130-139
[5]  
[Anonymous], 2008, 2008 IEEE POWER ENER
[6]  
Chen JL, 2005, ICEMS 2005: Proceedings of the Eighth International Conference on Electrical Machines and Systems, Vols 1-3, P1381
[7]  
Hamadi A, 2004, 2004 IEEE International Conference on Industrial Technology (ICIT), Vols. 1- 3, P645
[8]  
HOCHGRAF C, 1994, IEEE IND APPLIC SOC, P921, DOI 10.1109/IAS.1994.377528
[9]  
Jin T., 2004, P 20 ANN IEEE APPL P, P655
[10]   Genetic fuzzy control applied to the inverter of solid oxide fuel cell for power quality improvement [J].
Jurado, F ;
Valverde, M .
ELECTRIC POWER SYSTEMS RESEARCH, 2005, 76 (1-3) :93-105