On-line solid phase extraction system using an ion imprinted polymer based on dithizone chelating for selective preconcentration and determination of mercury(II) in natural waters by CV AFS

被引:31
作者
Lins, Suelen Santana [1 ]
Virgens, Cesario Francisco [1 ]
Lopes dos Santos, Walter Nei [1 ]
Santos Estevam, Idalia Helena [1 ]
Brandao, Geovani Cardoso [1 ]
Assis Felix, Caio Silva [2 ,3 ]
Costa Ferreira, Sergio Luis [2 ,3 ]
机构
[1] Univ Estado Bahia, Dept Ciencias Exatas & Terra, Programa Posgrad Quim Aplicada, Campus I,Rua Silveira Martins 2555, BR-41150000 Salvador, BA, Brazil
[2] Univ Fed Bahia, Inst Quim, Programa Posgrad Quim, Campus Ondina, BR-40170115 Salvador, BA, Brazil
[3] Univ Fed Bahia, Inst Nacl Ciencia & Tecnol Energia & Ambiente, BR-40170115 Salvador, BA, Brazil
关键词
Ion imprinted polymer; Dithizone; On-line preconcentration system; Mercury(II) determination; Multivariate optimization; Cold vapor atomic fluorescence spectrometry; SENSOR; REMOVAL; HG2+; SPECTROSCOPY; ALUMINUM; METALS; COPPER;
D O I
10.1016/j.microc.2019.104075
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present work is described a new on-line solid-phase extraction system using a novel ion imprinted polymer as adsorbent for the preconcentration and determination of mercury(II) in natural water samples by Cold Vapor Atomic Fluorescence Spectrometry (CV AFS). The ion imprinted polymer was prepared by the improved bulk polymerization technique, occurring in only 3 h, based on mercury(II)-dithizone chelate, using methacrylic acid as monomer, ethylene glycol dimethacrylate as cross-linking reagent, 2,2'-azobisisobutyronitrile as radical initiator, and dimethyl sulfoxide and acetonitrile as porogen solvents. The obtained polymer was characterized by Fourier Transform Infrared Spectroscopy (FTIR), Scanning Electron Microscopy (SEM), Thermogravimetry (TG), Derivative Thermogravimetry (DTG) and X-ray Diffraction (XRD). The on-line system was mounted by the easy coupling the mini-column packed with the Hg2+-IIP sorbent to the cold vapor system of the spectrometer. The optimum experimental conditions for the on-line preconcentration system were established employing multivariate methodology (two-level full factorial design and Doehlert matrix). Under the optimized conditions, limits of detection and quantification of 0.02 and 0.06 mu g L-1, and preconcentration factor of 29 were obtained for the determination of mercury using the developed on-line system, considering a sample volume of 50 mL. Precision expressed as a relative standard deviation (RSD%) was of 5.2% (n = 7) for a standard solution with mercury(II) concentration of 0.5 mu g L-1. Then, the on-line system was applied for the selective preconcentration and determination of mercury (II) in four natural water samples, and addition/recovery tests were performed to evaluate the accuracy of the method. All analyzed samples presented Hg2+ concentrations below the limit of quantification of the proposed method and the recovery values found were in range from 90 to 105%.
引用
收藏
页数:8
相关论文
共 49 条
[21]   A reversible fluorescence "off-on-off" sensor for sequential detection of aluminum and acetate/fluoride ions [J].
Gupta, Vinod Kumar ;
Mergu, Naveen ;
Kumawat, Lokesh Kumar ;
Singh, Ashok Kumar .
TALANTA, 2015, 144 :80-89
[22]   Selective naked-eye detection of Magnesium (II) ions using a coumarin-derived fluorescent probe [J].
Gupta, Vinod Kumar ;
Mergu, Naveen ;
Kumawat, Lokesh Kumar ;
Singh, Ashok Kumar .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 207 :216-223
[23]   Cadmium (II) ion sensing through p-tert-butyl calix[6]arene based potentiometric sensor [J].
Gupta, Vinod Kumar ;
Kumar, S. ;
Singh, R. ;
Singh, L. P. ;
Shoora, S. K. ;
Sethi, B. .
JOURNAL OF MOLECULAR LIQUIDS, 2014, 195 :65-68
[24]   Mercury selective potentiometric sensor based on low rim functionalized thiacalix [4]-arene as a cationic receptor [J].
Gupta, Vinod Kumar ;
Sethi, B. ;
Sharma, R. A. ;
Agarwal, Shilpi ;
Bharti, Arvind .
JOURNAL OF MOLECULAR LIQUIDS, 2013, 177 :114-118
[25]   A novel copper (II) selective sensor based on Dimethyl 4, 4′ (o-phenylene) bis(3-thioallophanate) in PVC matrix [J].
Gupta, Vinod Kumar ;
Singh, L. P. ;
Singh, Rakesh ;
Upadhyay, N. ;
Kaur, S. P. ;
Sethi, Bhavana .
JOURNAL OF MOLECULAR LIQUIDS, 2012, 174 :11-16
[26]  
Hanna W.G., 2003, International Journal of Polymeric Materials and Polymeric Biomaterials, V52, P471, DOI [10.1080/00914030304911, DOI 10.1080/00914030304911]
[27]  
Lacerda Luiz Drude de, 2008, Estud. av., V22, P173
[28]   Novel polymeric sorbents based on imprinted Hg(II)-diphenylcarbazone complexes for mercury removal from drinking water [J].
Mergola, Lucia ;
Scorrano, Sonia ;
Bloise, Ermelinda ;
Di Bello, Maria Pia ;
Catalano, Massimo ;
Vasapollo, Giuseppe ;
Del Sole, Roberta .
POLYMER JOURNAL, 2016, 48 (01) :73-79
[29]  
Nordberg GF, 2007, HANDBOOK ON THE TOXICOLOGY OF METALS, 3RD EDITION, P445, DOI 10.1016/B978-012369413-3/50078-1
[30]   Picosecond anisotropy of the transient absorption of the photochromic mercury dithizone complex in solution [J].
Paci, B ;
Nunzi, JM ;
Sertova, N ;
Petkov, I .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2000, 137 (2-3) :141-144