Sustainability, climate resiliency, and mitigation capacity of geothermal heat pump systems in cold regions

被引:15
作者
Gheysari, Ali Fatolahzadeh [1 ]
Hollander, Hartmut M. [1 ]
Maghoul, Pooneh [1 ]
Shalaby, Ahmed [1 ]
机构
[1] Univ Manitoba, Price Fac Engn, Winnipeg, MB R3T 5V6, Canada
关键词
Geothermal energy; Sustainability; Climate change; Adaptation; Mitigation; PERFORMANCE;
D O I
10.1016/j.geothermics.2020.101979
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Geothermal heat pump (GHP) systems have recently gained popularity in providing heat to buildings. In this study, the short-term and long-term performance of closed-loop horizontal GHP systems in cold regions and the effectiveness of seasonal balancing were investigated. A period of 50 years was simulated to cover the life of a conventional system. A repeating block of heat exchangers at three depths was modeled in a series of 3D multi physics finite element simulations. Two operation modes were defined, representing the non-balanced mode and the seasonal balancing through the injection of lake water in summer. The climate conditions at the ground surface were explicitly modeled by defining a temperature boundary condition. A novel AI framework was developed to generate the projections of ground surface temperatures from air temperature and other atmospheric variables. An artificial neural network was trained using the air and ground temperature measurements at the nearby weather station. Several training approaches were compared to minimize prediction errors. The model was then used to convert the air temperatures from downscaled outputs of the CanESM2 climate model into surface temperatures. Finite element models, representing the two operation modes under three climate change scenarios and various heat exchanger spacing, were simulated and verified by comparing the resulting ground temperatures with the local measurements. The outputs were processed into extraction power, thermal output, and carbon emissions. Results suggest that in order to attain a stable heat extraction throughout a year, heat exchangers should be placed at depths that are not affected by seasonal variations of surface conditions. Simulations revealed thermal depletion and its inverse correlation with heat exchanger spacing. The seasonal balancing operation approach showed enhancement in total thermal output by 55%. The system was found to be resilient when subjected to the major climate pathways. In a rough estimate based on the average carbon footprint of electricity production in Canada, a system with 100 heat exchangers was found to save up to 800 tons and 1300 tons of equivalent CO2 emissions over its life, under the non-balanced and balanced operation modes, respectively. <comment>Superscript/Subscript Available</comment
引用
收藏
页数:10
相关论文
共 24 条
[1]  
[Anonymous], 2016, Energy efficiency trends in Canada 1990 to 2013
[2]  
[Anonymous], 2019, Monthly Energy Review
[3]   Experimental and numerical investigation of heat transfer performance and sustainability of deep borehole heat exchangers coupled with ground source heat pump systems [J].
Cai, Wanlong ;
Wang, Fenghao ;
Liu, Jun ;
Wang, Zhihua ;
Ma, Zhenjun .
APPLIED THERMAL ENGINEERING, 2019, 149 :975-986
[4]  
Canada Energy Regulator, 2017, CAN REN POW LANDSC 2
[5]  
Carlson H., 1952, 2 HIGHW RES BOARD
[6]  
Chapuis S., 2009, IBPSA 2009 INT BUILD
[7]  
Chiasson A.D., 2000, ASHRAE Transactions, V106, P107, DOI DOI 10.1115/1.1330725
[8]   Feasibility study and numerical simulation of a ground source heat pump plant, applied to a residential building [J].
Desideri, U. ;
Sorbi, N. ;
Arcioni, L. ;
Leonardi, D. .
APPLIED THERMAL ENGINEERING, 2011, 31 (16) :3500-3511
[9]  
Environment and Climate Change Canada, 2020, 1981 2010 CLIM NORM
[10]   Subsurface heat flow in an urban environment [J].
Ferguson, G ;
Woodbury, AD .
JOURNAL OF GEOPHYSICAL RESEARCH-SOLID EARTH, 2004, 109 (B2)