Calcium phosphate interactions with titanium oxide and alumina substrates:: an XPS study

被引:46
作者
Barrère, F
Lebugle, A
Van Blitterswijk, CA
De Groot, K
Layrolle, P
Rey, C
机构
[1] IsoTis NV, NL-3720 AB Bilthoven, Netherlands
[2] Univ Twente, iBME, NL-7500 AE Enschede, Netherlands
[3] CIRIMAT, Lab Phosphates, Toulouse, France
[4] Leiden Univ, BRG, NL-2300 RA Leiden, Netherlands
关键词
D O I
10.1023/A:1023210817683
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Besides the excellent mechanical properties of titanium and alumina (Al2O3) in the case of load bearing applications, their bone-bonding properties are very different. In osseous environment, Al2O3 ceramic is encapsulated by fibrous tissues, whereas bone can bind directly to titanium, via its natural titanium dioxide (TiO2) passivation layer. So far, this calcification dissimilarity between TiO2 and Al2O3 was attributed to respectively their negative and positive surface charge under physiological conditions. The present study aims at studying the chemical interactions between TiO2 and Al2O3 (phase alpha) with the diverse ions contained in simulated body fluids (SBFs) buffered with trishydroxymethyl aminomethane (TRIS) at pH = 6.0 and pH = 7.4. After 1 h of immersion, TiO2 and alpha-Al2O3 powders were analyzed by X-ray photoelectron spectroscopy (XPS). The results indicated that Ca and HPO4 groups were present on TiO2 surface. In addition, HPO4 groups were found to be in a higher amount than Ca on TiO2, which does not comply with the surface charge theory. With regard to Al2O3, little HPO4 but no Ca was detected on its surface, and TRIS bound to Al2O3 substrate in all of the immersion experiments. The fact that both Ca and HPO4 were present at the vicinity of TiO2 might be at the origin of its calcification ability. On the other hand, Al2O3 did not show any affinity towards Ca and HPO4 ions. This might explain the inability of Al2O3 substrate to calcify. (C) 2003 Kluwer Academic Publishers.
引用
收藏
页码:419 / 425
页数:7
相关论文
共 24 条
  • [1] OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN
    ALBREKTSSON, T
    BRANEMARK, PI
    HANSSON, HA
    LINDSTROM, J
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02): : 155 - 170
  • [2] Nucleation of biomimetic Ca-P coatings on Ti6Al4V from a SBF x 5 solution: influence of magnesium
    Barrere, F
    van Blitterswijk, CA
    de Groot, K
    Layrolle, P
    [J]. BIOMATERIALS, 2002, 23 (10) : 2211 - 2220
  • [3] LONG-TERM RESULTS OF UNCEMENTED ALUMINA ACETABULAR IMPLANTS
    BOEHLER, M
    KNAHR, K
    PLENK, H
    WALTER, A
    SALZER, M
    SCHREIBER, V
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (01): : 53 - 59
  • [4] BUDAVARI S, 1996, MERCK INDEX, P9899
  • [5] BONE RESPONSE TO HYDROXYAPATITE-COATED AND COMMERCIALLY PURE TITANIUM IMPLANTS IN THE HUMAN ARTHRITIC KNEE
    CARLSSON, L
    REGNER, L
    JOHANSSON, C
    GOTTLANDER, M
    HERBERTS, P
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1994, 12 (02) : 274 - 285
  • [6] CONTAMINATION OF TITANIUM CASTINGS BY ALUMINUM-OXIDE BLASTING
    DARVELL, BW
    SAMMAN, N
    LUK, WK
    CLARK, RKF
    TIDEMAN, H
    [J]. JOURNAL OF DENTISTRY, 1995, 23 (05) : 319 - 322
  • [7] Droulas J. L., 1991, VIDE COUCHES MINCE S, V258, P39
  • [8] HYDRATION AND PREFERENTIAL MOLECULAR ADSORPTION ON TITANIUM INVITRO
    HEALY, KE
    DUCHEYNE, P
    [J]. BIOMATERIALS, 1992, 13 (08) : 553 - 561
  • [9] THE MECHANISMS OF PASSIVE DISSOLUTION OF TITANIUM IN A MODEL PHYSIOLOGICAL ENVIRONMENT
    HEALY, KE
    DUCHEYNE, P
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1992, 26 (03): : 319 - 338
  • [10] LEBUGLE A, 1998, COLLOID SURFACE B, V11, P15