Automated border detection in three-dimensional echocardiography: principles and promises

被引:70
作者
Leung, K. Y. Esther [1 ]
Bosch, Johan G. [1 ]
机构
[1] Erasmus MC, Thoraxctr Biomed Engn, NL-3000 CA Rotterdam, Netherlands
来源
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY | 2010年 / 11卷 / 02期
关键词
3D echocardiography; Automated analysis; Border detection; Segmentation; LEFT-VENTRICULAR VOLUME; TIME 3D ECHOCARDIOGRAPHY; MODEL-BASED SEGMENTATION; LEFT ATRIAL VOLUME; MAGNETIC-RESONANCE; EJECTION FRACTION; ULTRASOUND IMAGES; SEMIAUTOMATED QUANTIFICATION; MECHANICAL DYSSYNCHRONY; COMPUTED-TOMOGRAPHY;
D O I
10.1093/ejechocard/jeq005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Several automated border detection approaches for three-dimensional echocardiography have been developed in recent years, allowing quantification of a range of clinically important parameters. In this review, the background and principles of these approaches and the different classes of methods are described from a practical perspective, as well as the research trends to achieve a robust method.
引用
收藏
页码:97 / 108
页数:12
相关论文
共 87 条
[1]   Segmentation of real-time three-dimensional ultrasound for quantification of ventricular function: A clinical study on right and left ventricles [J].
Angelini, ED ;
Homma, S ;
Pearson, G ;
Holmes, JW ;
Laine, AF .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (09) :1143-1158
[2]   LV volume quantification via spatiotemporal analysis of real-time 3-D echocardiography [J].
Angelini, ED ;
Laine, AF ;
Takuma, S ;
Holmes, JW ;
Homma, S .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (06) :457-469
[3]   Assessment of left atrial volume and function by real-time three-dimensional echocardiography [J].
Anwar, Ashraf M. ;
Soliman, Osama I. I. ;
Geleijnse, Marcel L. ;
Nemes, Attila ;
Vletter, Wim B. ;
ten Cate, Folkert J. .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 123 (02) :155-161
[4]   Left atrial volume measurement with automated border detection by 3-dimensional echocardiography: comparison with magnetic resonance imaging [J].
Artang, Ramin ;
Migrino, Raymond Q. ;
Harmann, Leanne ;
Bowers, Mark ;
Woods, Timothy D. .
CARDIOVASCULAR ULTRASOUND, 2009, 7
[5]   Automatic segmentation of echocardiographic sequences by active appearance motion models [J].
Bosch, JG ;
Mitchell, SC ;
Lelieveldt, BPF ;
Nijland, F ;
Kamp, O ;
Sonka, M ;
Reiber, JHC .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (11) :1374-1383
[6]   A multiparametric and multiresolution segmentation algorithm of 3-D ultrasonic data [J].
Boukerroui, D ;
Basset, O ;
Baskurt, A ;
Gimenez, G .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2001, 48 (01) :64-77
[7]   Measurement of left ventricular dyssynchrony in patients with ischaemic cardiomyopathy: a comparison of real-time three-dimensional and tissue Doppler echocardiography [J].
Burgess, Malcolm I. ;
Jenkins, Carly ;
Chan, Jonathan ;
Marwick, Thomas H. .
HEART, 2007, 93 (10) :1191-1196
[8]   Objective evaluation of changes in left ventricular and atrial volumes during parabolic flight using real-time three-dimensional echocardiography [J].
Caiani, E. G. ;
Sugeng, L. ;
Weinert, L. ;
Capderou, A. ;
Lang, R. M. ;
Vaida, P. .
JOURNAL OF APPLIED PHYSIOLOGY, 2006, 101 (02) :460-468
[9]   Improved quantification of left ventricular mass based on endocardial and epicardial surface detection with real time three dimensional echocardiography [J].
Caiani, EG ;
Corsi, C ;
Sugeng, L ;
MacEneaney, P ;
Weinert, L ;
Mor-Avi, V ;
Lang, RM .
HEART, 2006, 92 (02) :213-219
[10]   Improved semiautomated quantification of left ventricular volumes and ejection fraction using 3-dimensional echocardiography with a full matrix-array transducer: Comparison with magnetic resonance imaging [J].
Caiani, EG ;
Corsi, C ;
Zamorano, J ;
Sugeng, L ;
MacEneaney, P ;
Weinert, L ;
Battani, R ;
Gutierrez, JL ;
Koch, R ;
de Isla, LP ;
Mor-Avi, V ;
Lang, RM .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2005, 18 (08) :779-788