Validation of a method to measure three-dimensional hip joint kinematics in subjects with femoroacetabular impingement

被引:2
作者
Ward, Thomas R. [1 ]
Hussain, Mafruha M. [2 ]
Pickering, Mark [2 ]
Perriman, Diana [1 ]
Burns, A., I [1 ]
Scarvell, Jennie [1 ,3 ]
Smith, Paul N. [1 ,4 ]
机构
[1] Canberra Hosp, Trauma & Orthopaed Res Unit, Bldg 6 Level 1,POB 2, Woden, ACT 2606, Australia
[2] Univ New South Wales, Australian Def Force Acad, Canberra, ACT, Australia
[3] Univ Canberra, Canberra, ACT, Australia
[4] Australian Natl Univ, Canberra, ACT, Australia
关键词
Femoroacetabular impingement; fluoroscopy; hip; image registration; kinematics; OSTEOARTHRITIS; ACCURACY; MOTION;
D O I
10.1177/1120700019883548
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: A kinematic measurement method combining dynamic motion and imaging, which captures the behaviour of the hip at terminal motion, may offer improved diagnostic accuracy and enhance our understanding of the mechanics of femoroacetabular impingement (FAI). Methods: 3 embalmed cadaveric hip/pelvis specimens with implanted Roentgen Stereophotogrammetric Analysis (RSA) beads were mounted on a custom rig and imaged with a fluoroscope in four poses to simulate a clinical impingement examination: in hip extension and in three positions: near impingement, early impingement and late impingement while simulating a flexion/adduction/internal rotation manoeuvre. Hip joint kinematics were measured using 2 methods and compared: RSA (gold standard) and a custom 3-dimensional to 2-dimensional (3D-2D) image registration method which matches 3D models developed from CT to 2D fluoroscopic images. Results: Using RSA as the gold standard, bias and precision of hip joint rotations measured using 3D-2D registration demonstrated maximums of 1.64 degrees and 3.96 degrees, respectively. However, if the single outlier was removed, bias and precision were 0.55 degrees and 1.38 degrees. Bias and precision of translations had maximums of 0.51 mm and 0.77 mm, respectively. Conclusions: This 3D to 2D registration method may offer a clinically useful solution for dynamic assessment of hip impingement. If 5-mm translation and 10 degrees of rotation represent a clinically significant difference in hip kinematics, the method's accuracy of approximately 1 mm displacement and 1 degrees rotation should enable detection of significant clinical differences.
引用
收藏
页码:133 / 139
页数:7
相关论文
共 50 条
  • [21] Three-dimensional assessment of subchondral arc and hip joint coverage angles in the asymptomatic young adult hip
    Aitken, Holly D.
    Goetz, Jessica E.
    Sailer, Wyatt M.
    Rivas, Dominic J. L.
    Farnsworth, Christine L.
    Upasani, Vidyadhar V.
    Holt, Joshua B.
    CLINICAL ANATOMY, 2024,
  • [22] Arthroscopic Treatment of Femoroacetabular Impingement of the Hip A New Technique to Access the Joint
    Horisberger, Monika
    Brunner, Alexander
    Herzog, Richard F.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (01) : 182 - 190
  • [23] Radiomics features outperform standard radiological measurements in detecting femoroacetabular impingement on three-dimensional magnetic resonance imaging
    Montin, Eros
    Kijowski, Richard
    Youm, Thomas
    Lattanzi, Riccardo
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2024, 42 (12) : 2796 - 2807
  • [24] An innovative method for the three-dimensional study of hip joint motion
    Bonneau, N.
    Bouhallier, J.
    Haeusler, M.
    Gagey, O.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2014, 17 : 56 - 57
  • [25] A three-dimensional measurement method on MR arthrography of the hip to classify femoro-acetabular impingement
    Cosimo Nardi
    Luisa De Falco
    Giuseppe Caracchini
    Linda Calistri
    Laura Mercatelli
    Stefano Cristin
    Chiara Lorini
    Edoardo Cavigli
    Nicholas Landini
    Martina Orlandi
    Christian Carulli
    Vittorio Miele
    Japanese Journal of Radiology, 2021, 39 : 1175 - 1185
  • [26] Femoroacetabular impingement syndrome is associated with alterations in hindfoot mechanics: A three-dimensional gait analysis study
    Hetsroni, Iftach
    Funk, Shany
    Ben-Sira, David
    Nyska, Meir
    Palmanovich, Ezequiel
    Ayalon, Moshe
    CLINICAL BIOMECHANICS, 2015, 30 (10) : 1189 - 1193
  • [27] Hip joint biomechanics during gait in people with and without symptomatic femoroacetabular impingement
    Diamond, Laura E.
    Wrigley, Tim V.
    Bennell, Kim L.
    Hinman, Rana S.
    O'Donnell, John
    Hodges, Paul W.
    GAIT & POSTURE, 2016, 43 : 198 - 203
  • [28] Evaluation of a multibody kinematics optimization method for three-dimensional canine pelvic limb gait analysis
    Lin, Cheng-Chung
    Wu, Ching-Ho
    Chou, Po-Yen
    Wang, Shi-Nuan
    Hsu, Wei-Ru
    Lu, Tung-Wu
    BMC VETERINARY RESEARCH, 2020, 16 (01)
  • [29] A method for measuring three-dimensional mandibular kinematics in vivo using single-plane fluoroscopy
    Chen, C-C
    Lin, C-C
    Chen, Y-J
    Hong, S-W
    Lu, T-W
    DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (01)
  • [30] Hip joint motion does not change one year after arthroscopic osteochondroplasty in patients with femoroacetabular impingement evaluated with dynamic radiostereometry
    Hansen, Lars
    de Raedt, Sepp
    Jorgensen, Peter Bo
    Mygind-Klavsen, Bjarne
    Romer, Lone
    Kaptein, Bart
    Soballe, Kjeld
    Stilling, Maiken
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2022, 9 (01)