A Comparison of Electrical Stimulation Levels Across Ears for Children With Sequential Bilateral Cochlear Implants

被引:5
|
作者
Galvin, Karyn L. [1 ]
Abdi, Roghayeh [1 ]
Dowell, Richard C. [1 ]
Nayagam, Bryony [1 ]
机构
[1] Univ Melbourne, Dept Audiol & Speech Pathol, 550 Swanton St, Carlton, Vic 3010, Australia
关键词
Children; Cochlear implant; Electrical stimulation levels; Programming; Sequential bilateral cochlear implants; CROSS-MODAL PLASTICITY; ELECTRODE IMPEDANCE; AUDITORY-NERVE; HEARING-LOSS; RESPONSES; POSITION; OUTCOMES; DEGENERATION; PERFORMANCE; THRESHOLD;
D O I
10.1097/AUD.0000000000000702
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objectives: To compare threshold and comfortable levels between a first and second cochlear implant (CI) for children, and to consider if the degree of difference between CIs was related to the age at bilateral implantation or the time between implants. A secondary objective was to examine the changes in levels over time for each CI. Design: Fifty-seven participants were selected from the 146 children and young adults who received a first Nucleus CI as a child, and received a second implant at the Royal Victorian Eye and Ear Hospital between September 2003 and December 2011. Exclusion criteria included an older implant type, incomplete array insertion, incomplete data available, and a pulse width higher than the default. Using measurements from clinical sessions, the threshold levels, comfortable levels, and dynamic range of electrical stimulation were compared at three electrode array regions and at the "initial" (first 10 weeks), 2-year, and 5-year postoperative time points. The T-ratio and C-ratio for each array region and each time point were calculated by dividing each mean (n = 3 electrodes) level for the second implant by that for the first implant. Results: The T-ratio was generally not significantly different to one, indicating no differences in threshold levels between the second and first implants; however, threshold levels were lower for the second implant in the apical region at the initial time point, and there was a significant difference in threshold levels in the apical region for children with a Contour Advance array for the second implant and an older-style array (i.e., Contour) for the first implant. For each implant individually, there were no significant changes in threshold levels across time. The C-ratio was significantly <1 at all electrode array regions at all time points, indicating lower comfortable levels for the second implant. The difference between implants was greater for children with variable array type (i.e., a Contour Advance array for the second implant and an older-style Contour or Straight array for the first implant). There was a significant increase in the C-ratio between the initial and 2-year time points, driven by an increase in comfortable levels for the second implant over this time period. A longer time between implants was associated with a narrower dynamic range, due to lower comfortable levels, for the second implant. Conclusions: For this sequentially implanted group, threshold levels were similar between implants, with some differences in cases with a newer array type for the second implant. Comfortable levels were lower for the second implant; although this difference decreased between the initial and 2-year postoperative time points, it was still evident at 5 years postoperative. A longer time between implants was associated with a narrower dynamic range. These findings are likely to apply to children using other brands of implant. Knowing what to expect in terms of programming children with a second implant will help clinicians to recognize and respond to unexpected outcomes. The work raises important questions to be addressed in future research regarding the implications of the programming outcomes for actual listening performance.
引用
收藏
页码:1174 / 1186
页数:13
相关论文
共 50 条
  • [41] School adjustment of adolescents with sequential bilateral cochlear implants in mainstream school
    Lee, Youngmee
    Jeong, Sung-Wook
    Jeong, Seung-Hwa
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2022, 163
  • [42] Vocabulary Growth in Mandarin-Speaking Children With Bilateral Cochlear Implants, Bimodal Stimulation, or Unilateral Cochlear Implants During the First Year After Activation
    Xu, Lei
    Luo, Jianfen
    Wang, Min
    Xie, Dianzhao
    Chao, Xiuhua
    Li, Jinming
    Liu, Xianqi
    He, Shuman
    Spencer, Linda
    Guo, Ling-Yu
    JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2022, 65 (04): : 1630 - 1645
  • [43] Characteristics of Stimulus Artifacts in EEG Recordings Induced by Electrical Stimulation of Cochlear Implants
    Li, Xiaoxia
    Nie, Kaibao
    Karp, Floyd
    Tremblay, Kelly L.
    Rubinstein, Jay T.
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 799 - 803
  • [44] Auditory perception and speech identification in children with cochlear implants tested with the EARS protocol
    Allum, JHJ
    Greisiger, R
    Straubhaar, S
    Carpenter, MG
    BRITISH JOURNAL OF AUDIOLOGY, 2000, 34 (05): : 293 - 303
  • [45] Electrical stimulation rate effects on speech perception in cochlear implants
    Arora, Komal
    Dawson, Pam
    Dowell, Richard
    Vandali, Andrew
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2009, 48 (08) : 561 - 567
  • [46] Song Recognition by Young Children With Cochlear Implants: Comparison Between Unilateral, Bilateral, and Bimodal Users
    Bartov, Tamar
    Most, Tova
    JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2014, 57 (05): : 1929 - 1941
  • [47] Spoken Language Skills in Children With Bilateral Hearing Aids or Bilateral Cochlear Implants at the Age of Three Years
    Valimaa, Taina T.
    Kunnari, Sari
    Aarnisalo, Antti A.
    Dietz, Aarno
    Hyvarinen, Antti
    Laitakari, Jaakko
    Mykkanen, Sari
    Rimmanen, Satu
    Salonen, Jaakko
    Sivonen, Ville
    Tennila, Tanja
    Tsupari, Teija
    Vikman, Sari
    Virokannas, Nonna
    Laukkanen-Nevala, Paivi
    Tolonen, Anna-Kaisa
    Tuohimaa, Krista
    Lopponen, Heikki
    EAR AND HEARING, 2022, 43 (01) : 220 - 233
  • [48] Sound localization ability of young children with bilateral cochlear implants
    Beijen, Jan-Willem
    Snik, Ad F. M.
    Mylanus, Emmanuel A. M.
    OTOLOGY & NEUROTOLOGY, 2007, 28 (04) : 479 - 485
  • [49] Bilateral Cochlear Implants and Bimodal Hearing: A Comparison of Quality of Life
    Lewis, Jessica H.
    Castellanos, Irina
    Tamati, Terrin N.
    Moberly, Aaron C.
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2024, 35 (05/06) : 127 - 134
  • [50] Effects of the Inter-Implant Interval and Listening Condition on Speech Perception in Children with Sequential Bilateral Cochlear Implants
    Lee, Youngmee
    COMMUNICATION SCIENCES AND DISORDERS-CSD, 2014, 19 (04): : 564 - 573