Laboratory and pilot plant scale study on the removal of radium, manganese and iron from drinking water using hydrous manganese oxide slurry

被引:2
|
作者
Bolobajev, Juri [1 ]
Leier, Maria [2 ]
Vaasma, Taavi [2 ]
Nilb, Nele [3 ]
Salupere, Siiri [2 ]
机构
[1] Tallinn Univ Technol, Dept Mat & Environm Technol, Ehitajate Tee 5, EE-19086 Tallinn, Estonia
[2] Univ Tartu, Inst Phys, Lab Environm Phys, W Ostwaldi 1, EE-50411 Tartu, Estonia
[3] Viimsi Vesi AS, Nelgi Tee 1, EE-74001 Viimsi, Harju, Estonia
来源
JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING | 2022年 / 10卷 / 06期
关键词
Hydrous manganese oxide; Drinking water treatment; Research with scale-up; Radium isotopes; Radionuclides; GROUNDWATER;
D O I
10.1016/j.jece.2022.108942
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The presence of naturally occurring radionuclides in drinking water can pose health risks to consumers. Processes of radionuclides removal could result in the accumulation of radioactive elements in a treatment facility, e.g. in filter materials, causing the formation of naturally occurring radioactive materials (NORM). Development of water treatment solutions mostly puts the emphasis on radionuclide removal leaving the generation of (NORM) out of focus. To meet current radiation protection standards, a broader view is necessary -water purification from radionuclides is an optimization assignment between radionuclide removal and accumulation rates. In this work, the injection of HMO slurry into the raw water was tested for simultaneous reduction of the radium, iron, and manganese. Experiments were performed in a lab scale setup and then upscaled to a pilot plant. Laboratory study allowed to optimize the sequence of water treatment steps. The pilot plant was operated over the course of two years demonstrating the removal of Fe and Mn from water as high as 97% and 83%, respectively. The optimal dose of HMO for radium isotopes removal was found to be 1.3 gMnO(2)center dot m(-3). At this dose the concen-trations of Ra-226 and Ra-228 were reduced from 0.358 and 0.470 to 0.048 and 0.043 Bq center dot L-1, respectively. Thereupon, radionuclides content in drinking water was decreased far below the parametric value of 0.1 mSv center dot year(-1). In terms of NORM generation, the studied approach enabled to slow down the accumulation of radionuclides in the filter material prolonging its operation cycle.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Synergistic removal of iron and manganese with organic matters from water with submerged biofilter
    Zhang, Jin
    Mi, Xin
    Wei, Mengxue
    Hui, Zhaochong
    JOURNAL OF WATER PROCESS ENGINEERING, 2024, 67
  • [22] Removal of ammonium, iron and manganese from potable water in biofiltration units: a review
    Tekerlekopoulou, Athanasia G.
    Pavlou, Stavros
    Vayenas, Dimitrios V.
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2013, 88 (05) : 751 - 773
  • [23] In situ and laboratory treatment tests for lowering of excess manganese and iron in drinking water sourced from river-groundwater interaction
    Yuce, Galip
    Alptekin, Candan
    ENVIRONMENTAL EARTH SCIENCES, 2013, 70 (06) : 2827 - 2837
  • [24] Start-Up of a Biofilter in a Full-Scale Groundwater Treatment Plant for Iron and Manganese Removal
    Zeng, Huiping
    Yin, Can
    Zhang, Jie
    Li, Dong
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (05)
  • [25] Kinetic evaluation of simultaneous COD, ammonia and manganese removal from drinking water using a biological aerated filter system
    Abu Hasan, Hassimi
    Abdullah, Siti Rozaimah Sheikh
    Kamarudin, Siti Kartom
    Kofli, Noorhisham Tan
    Anuar, Nurina
    SEPARATION AND PURIFICATION TECHNOLOGY, 2014, 130 : 56 - 64
  • [26] Health Risk Assessment of Arsenic, Manganese, and Iron from Drinking Water for High School Children
    Rahman, Md. Aminur
    Kumar, Sazal
    Lamb, Dane
    Rahman, Mohammad Mahmudur
    WATER AIR AND SOIL POLLUTION, 2021, 232 (07):
  • [27] Catalytic oxidation removal of manganese from groundwater by iron-manganese co-oxide filter films under anaerobic conditions
    Cheng, Ya
    Xiong, Weiyao
    Huang, Tinglin
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 737
  • [28] Nanoplastics removal during drinking water treatment: Laboratory- and pilot-scale experiments and modeling
    Pulido-Reyes, Gerardo
    Magherini, Leonardo
    Bianco, Carlo
    Sethi, Rajandrea
    von Gunten, Urs
    Kaegi, Ralf
    Mitrano, Denise M.
    JOURNAL OF HAZARDOUS MATERIALS, 2022, 436
  • [29] Using Iron-Manganese Co-Oxide Filter Film to Remove Ammonium from Surface Water
    Zhang, Ruifeng
    Huang, Tinglin
    Wen, Gang
    Chen, Yongpan
    Cao, Xin
    Zhang, Beibei
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2017, 14 (07)
  • [30] Arsenic removal from drinking water by electrocoagulation using iron electrodes
    Ucar, Ceren
    Baskan, Meltem Bilici
    Pala, Aysegul
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2013, 30 (10) : 1889 - 1895