Solid-phase microextraction of phthalate esters from aqueous media by electrochemically deposited carbon nanotube/polypyrrole composite on a stainless steel fiber

被引:126
作者
Asadollahzadeh, H. [1 ]
Noroozian, E. [1 ]
Maghsoudi, Sh. [1 ]
机构
[1] Shahid Bahonar Univ Kerman, Dept Chem, Kerman, Iran
关键词
Carbon nanotube; Polypyrrole; Composite polymer; Solid-phase microextraction; Phthalate esters; Gas chromatography; GAS-CHROMATOGRAPHY; WATER SAMPLES; POLYPYRROLE COMPOSITES; ACID-ESTERS; EXTRACTION; NANOTUBES; OPTIMIZATION; ADSORPTION; POLYMERS; MILK;
D O I
10.1016/j.aca.2010.04.029
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel direct immersion solid-phase microextraction (DI-SPME) method using a stainless steel wire electrochemically coated with oxidized multiwalled carbon nanotubes-polypyrrole composite (MWCNTs-PPy) was used in the gas chromatographic (GC) determination of phthalate esters in aqueous samples. The composite coating did not swell in organic solvents nor did it strip off from the substrate. It was also highly stable and extremely adherent to the surface of the steel fiber. The effects of various parameters on the efficiency of SPME process such as extraction time, extraction temperature, ionic strength, desorption time, and desorption temperature were studied. Under optimized conditions, the detection limits for the phthalate esters varied between 0.05 and 0.1 ng mL(-1), the inter-day and intra-day relative standard deviations for various phthalates at 1.0 ng mL(-1) concentration level (N = 7) using a single fiber were 6.2-10.2% and 7.7-10.5, respectively. The fiber-to fiber RSD% (N = 3) was 9.3-12.1% at 10 ng mL(-1). The linear ranges varied between 0.5 and 300 ng mL(-1). The method was successfully applied to the analysis of mineral water samples with the recoveries from 90 to 113%. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:32 / 38
页数:7
相关论文
共 47 条
[1]  
Belardi R.P., 1989, WATER POLLUT RES J C, V24, P179, DOI DOI 10.2166/WQRJ.1989.010
[2]   Application of on-line solid-phase extraction-gas chromatography-mass spectrometry to the determination of endocrine disruptors in water samples [J].
Brossa, L ;
Marcé, RM ;
Borrull, F ;
Pocurull, E .
JOURNAL OF CHROMATOGRAPHY A, 2002, 963 (1-2) :287-294
[3]   Automated solid phase extraction and quantitative analysis of human milk for 13 phthalate metabolites [J].
Calafat, AM ;
Slakman, AR ;
Silva, MJ ;
Herbert, AR ;
Needham, LL .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 805 (01) :49-56
[4]   Determination of phthalates and adipate in bottled water by headspace solid-phase microextraction and gas chromatography/mass spectrometry [J].
Cao, Xu-Liang .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1178 (1-2) :231-238
[5]  
Chen GZ, 2000, ADV MATER, V12, P522, DOI 10.1002/(SICI)1521-4095(200004)12:7<522::AID-ADMA522>3.0.CO
[6]  
2-S
[7]   MultiSimplex optimisation of the solid-phase microextraction-gas chromatographic-mass spectrometric determination of polycyclic aromatic hydrocarbons, polychlorinated biphenyls and phthalates from water samples [J].
Cortazar, E ;
Zuloaga, O ;
Sanz, J ;
Raposo, JC ;
Etxebarria, N ;
Fernández, LA .
JOURNAL OF CHROMATOGRAPHY A, 2002, 978 (1-2) :165-175
[8]   Niobium(V) oxide coated on thin glass-ceramic rod as a solid phase microextraction fiber [J].
de Oliveira, AF ;
da Silveira, CB ;
de Campos, SD ;
de Campos, EA ;
Carasek, E .
TALANTA, 2005, 66 (01) :74-79
[9]  
DEALPENDURADA MF, 2000, J CHROMATOGR A, V889, P3
[10]   Recent developments in solid-phase microextraction coatings and related techniques [J].
Dietz, C ;
Sanz, J ;
Cámara, C .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1103 (02) :183-192