Three-dimensional ultrashort echo-time imaging using a FLORET trajectory

被引:16
作者
Robison, Ryan K. [1 ]
Anderson, Ashley G., III [1 ]
Pipe, James G. [1 ]
机构
[1] Barrow Neurol Inst, Imaging Res, 350 West Thomas Rd, Phoenix, AZ 85013 USA
关键词
UTE; spiral; FLORET; non-Cartesian; MAGNETIC-RESONANCE; HUMAN BRAIN; SODIUM MRI; DESIGN; SPIRALS;
D O I
10.1002/mrm.26500
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThree-dimensional ultrashort echo-time (UTE) imaging commonly makes use of an isotropic 3D radial projection acquisition. The FLORET sequence is proposed and evaluated as a more efficient alternative. Methods: The properties of the FLORET trajectory are contrasted with those of a 3D radial projection trajectory. The theoretical advantages of FLORET, including greater sampling and SNR efficiency, are evaluated based upon experimental data. The effect of T2* decay on FLORET is analyzed in comparison to the 3D radial, Cones, and Density Adapted Radial trajectories. FLORET UTE image quality is compared with 3D radial UTE image quality. ResultsFLORET is shown to have several advantages over 3D radial acquisitions with respect to image quality, scan time, signal-to-noise, and off-resonance blurring for UTE data. The signal and resolution losses from T2* decay for a FLORET acquisition are shown to be comparable to those of Density Adapted Radial and Density Compensated Cones trajectories. ConclusionThe FLORET sequence is recommended as an alternative to 3D radial projection sequences for musculoskeletal UTE imaging as well as other UTE applications that accommodate modest to long per shot sampling times. FLORET is not recommended for imaging extremely short T-2 species such as dentin. Magn Reson Med 78:1038-1049, 2017. (c) 2016 International Society for Magnetic Resonance in Medicine
引用
收藏
页码:1038 / 1049
页数:12
相关论文
共 24 条
[1]  
Ahunbay E, 2000, MAGNET RESON MED, V44, P491, DOI 10.1002/1522-2594(200009)44:3<491::AID-MRM22>3.0.CO
[2]  
2-Z
[3]  
Anderson AG, 2016, P 24 ANN M ISMRM SIN, P1758
[4]   Clinically Constrained Optimization of flexTPI Acquisition Parameters for the Tissue Sodium Concentration Bioscale [J].
Atkinson, Ian C. ;
Lu, Aiming ;
Thulborn, Keith R. .
MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (04) :1089-1099
[5]   Fast three dimensional sodium imaging [J].
Boada, FE ;
Gillen, JS ;
Shen, GX ;
Chang, SY ;
Thulborn, KR .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (05) :706-715
[6]   Spectrally weighted twisted projection imaging: Reducing T-2 signal attenuation effects in fast three-dimensional sodium imaging [J].
Boada, FE ;
Shen, GX ;
Chang, SY ;
Thulborn, KR .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (06) :1022-1028
[7]   Design and analysis of a practical 3D cones trajectory [J].
Gurney, PT ;
Hargreaves, BA ;
Nishimura, DG .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (03) :575-582
[8]  
Gurney PT, 3D CONES TRAJECTORY
[9]   Optimized 3D Ultrashort Echo Time Pulmonary MRI [J].
Johnson, Kevin M. ;
Fain, Sean B. ;
Schiebler, Mark L. ;
Nagle, Scott .
MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (05) :1241-1250
[10]   Quantitative Sodium Imaging With a Flexible Twisted Projection Pulse Sequence [J].
Lu, Aiming ;
Atkinson, Ian C. ;
Claiborne, Theodore C. ;
Damen, Frederick C. ;
Thulborn, Keith R. .
MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (06) :1583-1593