Serial Block-Face Scanning Electron Microscopy (SBF-SEM) of Biological Tissue Samples

被引:17
作者
Courson, Justin A. [1 ]
Landry, Paul T. [1 ]
Do, Thao [1 ]
Spehlmann, Eric [2 ]
Lafontant, Pascal J. [2 ]
Patel, Nimesh [1 ]
Rumbaut, Rolando E. [3 ,4 ]
Burns, Alan R. [1 ,4 ]
机构
[1] Univ Houston, Coll Optometry, Houston, TX 77004 USA
[2] DePauw Univ, Dept Biol, Greencastle, IN 46135 USA
[3] Michael E DeBakey VA Med Ctr, Ctr Translat Res Inflammatory Dis CTRID, Houston, TX USA
[4] Baylor Coll Med, Childrens Nutr Ctr, Houston, TX 77030 USA
来源
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS | 2021年 / 169期
基金
美国国家卫生研究院;
关键词
OSMIUM-TETROXIDE; VOLUME; RESOLUTION; RECONSTRUCTION; FERROCYANIDE; DECELERATION; STEREOLOGY; SECTIONS; FIXATION; CONTRAST;
D O I
10.3791/62045
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Serial block-face scanning electron microscopy (SBF-SEM) allows for the collection of hundreds to thousands of serially-registered ultrastructural images, offering an unprecedented three-dimensional view of tissue microanatomy. While SBF-SEM has seen an exponential increase in use in recent years, technical aspects such as proper tissue preparation and imaging parameters are paramount for the success of this imaging modality. This imaging system benefits from the automated nature of the device, allowing one to leave the microscope unattended during the imaging process, with the automated collection of hundreds of images possible in a single day. However, without appropriate tissue preparation cellular ultrastructure can be altered in such a way that incorrect or misleading conclusions might be drawn. Additionally, images are generated by scanning the block-face of a resin-embedded biological sample and this often presents challenges and considerations that must be addressed. The accumulation of electrons within the block during imaging, known as "tissue charging," can lead to a loss of contrast and an inability to appreciate cellular structure. Moreover, while increasing electron beam intensity/voltage or decreasing beam-scanning speed can increase image resolution, this can also have the unfortunate side effect of damaging the resin block and distorting subsequent images in the imaging series. Here we present a routine protocol for the preparation of biological tissue samples that preserves cellular ultrastructure and diminishes tissue charging. We also provide imaging considerations for the rapid acquisition of high-quality serial-images with minimal damage to the tissue block.
引用
收藏
页数:33
相关论文
共 69 条
  • [1] THE USE OF OSMIUM-TETROXIDE POTASSIUM FERROCYANIDE AS AN EXTRACELLULAR TRACER IN ELECTRON-MICROSCOPY
    AGUAS, AP
    [J]. STAIN TECHNOLOGY, 1982, 57 (02): : 69 - 73
  • [2] ANDERSON HR, 1994, ANAL QUANT CYTOL, V16, P253
  • [3] [Anonymous], 2010, Microscopy and Microanalysis, DOI [10.1017/S1431927610055170, DOI 10.1017/S1431927610055170]
  • [4] Chemical analysis of osmium tetroxide staining in adipose tissue using imaging ToF-SIMS
    Belazi, Dalila
    Sole-Domenech, Santiago
    Johansson, Bjorn
    Schalling, Martin
    Sjovall, Peter
    [J]. HISTOCHEMISTRY AND CELL BIOLOGY, 2009, 132 (01) : 105 - 115
  • [5] Microscopy Image Browser: A Platform for Segmentation and Analysis of Multidimensional Datasets
    Belevich, Ilya
    Joensuu, Merja
    Kumar, Darshan
    Vihinen, Helena
    Jokitalo, Eija
    [J]. PLOS BIOLOGY, 2016, 14 (01)
  • [6] The versatile electron microscope: An ultrastructural overview of autophagy
    Biazik, Joanna
    Vihinen, Helena
    Anwar, Tahira
    Jokitalo, Eija
    Eskelinen, Eeva-Liisa
    [J]. METHODS, 2015, 75 : 44 - 53
  • [7] Reporting methods for processing and analysis of data from serial block face scanning electron microscopy
    Borrett, S.
    Hughes, L.
    [J]. JOURNAL OF MICROSCOPY, 2016, 263 (01) : 3 - 9
  • [8] Deceleration of probe beam by stage bias potential improves resolution of serial block-face scanning electron microscopic images
    Bouwer, James C.
    Deerinck, Thomas J.
    Bushong, Eric
    Astakhov, Vadim
    Ramachandra, Ranjan
    Peltier, Steven T.
    Ellisman, Mark H.
    [J]. ADVANCED STRUCTURAL AND CHEMICAL IMAGING, 2016, 2
  • [9] Wiring specificity in the direction-selectivity circuit of the retina
    Briggman, Kevin L.
    Helmstaedter, Moritz
    Denk, Winfried
    [J]. NATURE, 2011, 471 (7337) : 183 - U67
  • [10] Assessment of the Alveolar Capillary Network in the Postnatal Mouse Lung in 3D Using Serial Block-Face Scanning Electron Microscopy
    Buchacker, Tobias
    Muehlfeld, Christian
    Wrede, Christoph
    Wagner, Willi L.
    Beare, Richard
    McCormick, Matt
    Grothausmann, Roman
    [J]. FRONTIERS IN PHYSIOLOGY, 2019, 10