Novel Ultrasound Anatomical Measurement of the Deep Transverse Metatarsal Ligament: An Intra-Rater Reliability and Inter-Rater Concordance Study

被引:2
|
作者
del Mar Ruiz-Herrera, Maria [1 ]
Marcos-Tejedor, Felix [2 ]
Aldana-Caballero, Alberto [3 ]
Calvo-Lobo, Cesar [4 ]
Rodriguez-Sanz, David [4 ]
Moroni, Simone [5 ]
Konschake, Marko [6 ]
Mohedano-Moriano, Alicia [2 ]
Aceituno-Gomez, Javier [7 ,8 ]
Criado-alvarez, Juan Jose [2 ,9 ]
机构
[1] Maria Mar Ruiz Clin, 13600 Alcazar San Juan, Ciudad Real, Spain
[2] Univ Castilla La Mancha, Fac Hlth Sci, Dept Med Sci, Toledo 45600, Spain
[3] Univ Castilla La Mancha, Fac Hlth Sci, Dept Nursing Physiotherapy & Occupat Therapy, Toledo 45600, Spain
[4] Univ Complutense Madrid, Fac Nursing Physioterapy & Podiatry, Madrid 28040, Spain
[5] Cent Univ Catalunya UVic Ucc, Univ Vic, Fac Hlth Sci Manresa, Dept Podiatry, Barcelona 08500, Spain
[6] Med Univ Innsbruck MUI, Inst Clin & Funct Anat, Dept Anat Histol & Embryol, A-6020 Innsbruck, Austria
[7] Hlth Serv Castilla La Mancha, Management Integrated Assistance Talavera Reina, Toledo 45600, Spain
[8] Univ Castilla La Mancha, Fac Nursing & Physiotherapy, Dept Nursing Physiotherapy & Occupat Therapy, Toledo 45600, Spain
[9] Inst Hlth Sci, Dept Hlth, Toledo 45600, Spain
关键词
Morton's Neuroma; deep transverse metatarsal ligament; ultrasound; concordance; SAMPLE-SIZE REQUIREMENTS; UNDERGRADUATE STUDENTS; MORTONS; ULTRASONOGRAPHY;
D O I
10.3390/jcm11092553
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Insufficient space below the Deep Transverse Metatarsal Ligament (DTML) could be an etiological factor for Morton's Neuroma (MN). To date, there is a lack of studies measuring the space below the DTML. For this reason, this study assesses the intra- and inter-rater concordance and reproducibility of measurements of the space below the DTML between the third and the fourth metatarsal heads (M3 and M4) using ultrasound imaging to assess and verify the reliability and reproducibility of measurements of the space under the DTML. Forty feet from twenty patients were examined using ultrasound by three trained evaluators at two different times. The two measurements taken on each foot were: base (b)-distance between M3 and M4, and height (h)-distance between the DTML and the plantar skin surface. This was a quantitative, observational, analytical study. The concordance rate between observers for measurements of height and base were 98.5% and 99.5%, respectively. The mean area obtained of the space was 54.6 mm(2) and 57.2 mm(2) for both the left and right foot (p > 0.05). Reproducibility over time calculated in pre- and post-measurements showed an intraclass correlation coefficient of 1.00 (95%CI: 0.99-1.00), which leads us to conclude that the measurements are perfectly reproducible. Both measurements (height and base) of the space under the DTML, performed by ultrasound, are reliable and reproducible.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Intra-rater and inter-rater reliability of the standardized ultrasound protocol for assessing subacromial structures
    Hougs Kjaer, Birgitte
    Ellegaard, Karen
    Wieland, Ina
    Warming, Susan
    Juul-Kristensen, Birgit
    PHYSIOTHERAPY THEORY AND PRACTICE, 2017, 33 (05) : 398 - 409
  • [2] Ultrasound imaging in patients with hip pain and suspected hip osteoarthritis: an inter-rater and intra-rater reliability study
    Clausen, Stine
    Kjaer, Soren
    Fredberg, Ulrich
    Terslev, Lene
    Hartvigsen, Jan
    Arnbak, Bodil
    BMJ OPEN, 2020, 10 (11):
  • [3] Ultrasound Imaging Analysis of the Lumbar Multifidus Muscle Echo Intensity: Intra-Rater and Inter-Rater Reliability of a Novice and an Experienced Rater
    Fortin, Maryse
    Rosenstein, Brent
    Levesque, Jerome
    Nandlall, Neil
    MEDICINA-LITHUANIA, 2021, 57 (05):
  • [4] Measurement of glenohumeral joint translation using real-time ultrasound imaging: A physiotherapist and sonographer intra-rater and inter-rater reliability study
    Rathi, Sangeeta
    Taylor, Nicholas F.
    Gee, Jamie
    Green, Rodney A.
    MANUAL THERAPY, 2016, 26 : 110 - 116
  • [5] The inter- and intra-rater reliability of the Maestro and Barroco metatarsal length measurement techniques
    Ali, Zainab
    Karim, Hassan
    Wali, Navid
    Naraghi, Reza
    JOURNAL OF FOOT AND ANKLE RESEARCH, 2018, 11
  • [6] Intra and Inter-Rater Reliability of Ultrasound in Plantar Fascia Thickness Measurement
    Nakhaee, Masoomeh
    Mousavi, Mohammad Ebrahim
    Mohseni-Bandpei, Mohammad Ali
    Shakourirad, Ali
    Safari, Mohammad Reza
    Kashani, Reza Vahab
    Baneshi, Mohammad Reza
    Nakhaei, Masoud
    IRANIAN JOURNAL OF RADIOLOGY, 2018, 15 (03)
  • [7] Intra- and inter-rater reliability of ultrasound measures of the anterior cruciate ligament
    Sievert, Zachary A.
    Bennett, Hunter J.
    Weinhandl, Joshua T.
    JOURNAL OF ULTRASOUND, 2021, 24 (01) : 49 - 55
  • [8] Intra- and inter-rater reliability of ultrasound measures of the anterior cruciate ligament
    Zachary A. Sievert
    Hunter J. Bennett
    Joshua T. Weinhandl
    Journal of Ultrasound, 2021, 24 : 49 - 55
  • [9] Reliability of ultrasound assessment of the rectus femoris muscle thickness: intra-rater, inter-rater, and inter-day analysis accounting for age and sex
    Stausholm, Martin Bjorn
    da Silva, Katielle Rodrigues
    Inacio, Pedro Augusto
    de Sa Filho, Alberto Souza
    Lopes-Martins, Pedro Sardinha Leonardo
    Bjordal, Jan Magnus
    Leonardo, Patricia Sardinha
    Lopes-Martins, Rodrigo Alvaro B.
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [10] Ultrasound imaging of patellar tendon thickness in elite sprint track cyclists and elite soccer players: An intra-rater and inter-rater reliability study
    Klich, Sebastian
    Kosendiak, Aureliusz
    Krymski, Igor
    Kawczynski, Adam
    Madeleine, Pascal
    Fernandez-de-las-Penas, Cesar
    PLOS ONE, 2022, 17 (07):