Mucin and carbon nanotube-based biosensor for detection of glucose in human plasma

被引:51
作者
Comba, Fausto N. [1 ]
Romero, Marcelo R. [2 ]
Garay, Fernando S. [3 ]
Baruzzi, Ana M. [3 ]
机构
[1] Univ Tecnol Nacl, Fac Reg Villa Maria, Dept Ingn Quim, CIT Villa Maria CONICET, RA-5900 Cordoba, Argentina
[2] Univ Nacl Cordoba, Fac Ciencias Quim, Dept Quim Organ, IPQA CONICET, Ciudad Univ, RA-5000 Cordoba, Argentina
[3] Univ Nacl Cordoba, Fac Ciencias Quim, Dept Fis Quim, INFIQC CONICET, Ciudad Univ, RA-5000 Cordoba, Argentina
关键词
Novel hydrogel; Carbon nanotubes; Mucin; Glucose oxidase; Biosensor; Human plasma; AMPEROMETRIC BIOSENSOR; OXIDASE; OPTIMIZATION; SENSORS;
D O I
10.1016/j.ab.2018.04.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This work reports an amperometric enzyme-electrode prepared with glucose oxidase, which have been immobilized by a cross-linking step with glutaraldehyde in a mixture containing albumin and a novel carbon nanotubes-mucin composite (CNT-muc). The obtained hydrogel matrix was trapped between two polycarbonate membranes and then fixed at the surface of a Pt working electrode. The developed biosensor was optimized by evaluating different compositions and the analytical properties of an enzymatic matrix with CNT-muc. Then, the performance of the resulting enzymatic matrix was evaluated for direct glucose quantification in human blood plasma. The novel CNT-muc composite provided a sensitivity of 0.44 +/- 0.01 mA M-1 and a response time of 28 +/- 2 s. These values were respectively 20% higher and 40% shorter than those obtained with a sandwich-type biosensor prepared without CNT. Additionally, CNT-muc based biosensor exhibited more than 3 orders of magnitude of linear dynamic calibration range and a detection limit of 3 mu M. The short-term and long-term stabilities of the biosensors were also examined and excellent results were obtained through successive experiments performed within the first 60 days from their preparation. Finally, the storage stability was remarkable during the first 300 days.
引用
收藏
页码:34 / 40
页数:7
相关论文
共 36 条
[1]   Development of an Amperometric-Based Glucose Biosensor to Measure the Glucose Content of Fruit [J].
Ang, Lee Fung ;
Por, Lip Yee ;
Yam, Mun Fei .
PLOS ONE, 2015, 10 (03)
[2]  
[Anonymous], DIABETES CARE S1
[3]   Amperometric glucose biosensor based on glucose oxidase immobilized over chitosan nanoparticles from gladius of Uroteuthis duvauceli [J].
Anusha, J. R. ;
Raj, C. Justin ;
Cho, Bo-Bae ;
Fleming, Albin T. ;
Yu, Kook-Hyun ;
Kim, Byung Chul .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 215 :536-543
[4]   Mouthguard biosensor with telemetry system for monitoring of saliva glucose: A novel cavitas sensor [J].
Arakawa, Takahiro ;
Kuroki, Yusuke ;
Nitta, Hiroki ;
Chouhan, Prem ;
Toma, Koji ;
Sawada, Shin-ichi ;
Takeuchi, Shuhei ;
Sekita, Toshiaki ;
Akiyoshi, Kazunari ;
Minakuchi, Shunsuke ;
Mitsubayashi, Kohji .
BIOSENSORS & BIOELECTRONICS, 2016, 84 :106-111
[5]   Glucose oxidase - An overview [J].
Bankar, Sandip B. ;
Bule, Mahesh V. ;
Singhal, Rekha S. ;
Ananthanarayan, Laxmi .
BIOTECHNOLOGY ADVANCES, 2009, 27 (04) :489-501
[6]   Comparative behavior of glucose oxidase and oxalate oxidase immobilized in mucin/chitosan hydrogels for biosensors applications [J].
Benavidez, Tomas E. ;
Baruzzi, Ana M. .
POLYMER, 2012, 53 (02) :438-444
[7]   Physicochemical properties of a mucin/chitosan matrix used for the development of an oxalate biosensor [J].
Benavidez, Tomas E. ;
Alvarez, Cecilia I. ;
Baruzzi, Ana M. .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 143 (02) :660-665
[8]   Amperometric Biosensor Based on Immobilization of Oxalate Oxidase in a Mucin/Chitosan Matrix [J].
Benavidez, Tomas E. ;
Capra, Raul H. ;
Alvarez, Cecilia I. ;
Baruzzi, Ana M. .
ELECTROANALYSIS, 2009, 21 (07) :837-843
[9]   Analysis and optimization of a hydrogel matrix for the development of a sandwich-type glucose biosensor [J].
Colombo, Lucas ;
Maria Baruzzi, Ana ;
Sebastian Garay, Fernando .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 211 :125-130
[10]  
Davis F, 2009, MICRO FUEL CELLS: PRINCIPLES AND APPLICATIONS, P243, DOI 10.1016/B978-0-12-374713-6.00006-8