Long-shunt and short-shunt connections on dynamic performance of a SEIG feeding an induction motor load

被引:61
作者
Wang, L [1 ]
Lee, CH [1 ]
机构
[1] Natl Cheng Kung Univ, Dept Elect Engn, Tainan 70101, Taiwan
关键词
induction generator; self excitation; voltage variation;
D O I
10.1109/60.849108
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents a comparative study of long-shunt and short-shunt configurations on dynamic performance of an isolated self-excited induction generator (SEIG) feeding an induction motor (IM) load, The studied IM is suddenly connected to the output terminals of the studied configurations of the SEIG, Both simulated results and experimental results based on laboratory 1, 1 kW induction machines are clearly compared to examine the effects of both connections on voltage variation of the studied SEIG. The analyzed results show that the long-shunt configuration may lead to unwanted oscillations while the short-shunt connection provides better voltage variation, The eigenvalue technique is also employed to examine the possible voltage collapse and unstable conditions in the studied SEIG-IM system.