Mixed-mode chromatography characteristics of chiralpak ZWIX(+) and ZWIX(-) and elucidation of their chromatographic orthogonality for LC x LC application

被引:19
作者
Baeurer, Stefanie [1 ]
Ferri, Martina [1 ,2 ]
Carotti, Andrea [2 ]
Neubauer, Stefan [1 ]
Sardella, Roccaldo [2 ]
Laemmerhofer, Michael [1 ]
机构
[1] Univ Tubingen, Inst Pharmaceut Sci, Pharmaceut Bioanalysis, Morgenstelle 8, D-72076 Tubingen, Germany
[2] Univ Perugia, Dept Pharmaceut Sci, Via Liceo 1, I-06123 Perugia, Italy
关键词
Zwitterionic ion-exchangers; Mixed-mode chromatography; MMC; Hydrophilic interaction chromatography; Molecular dynamics; Fully comprehensive two-dimensional liquid chromatography; Impurity profiling; 2-DIMENSIONAL LIQUID-CHROMATOGRAPHY; REVERSED-PHASE; HYDROPHILIC-INTERACTION; STATIONARY PHASES; MASS-SPECTROMETRY; PEAK-CAPACITY; SEPARATIONS; OPTIMIZATION; PROGRAM; SILICA;
D O I
10.1016/j.aca.2019.09.068
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two-dimensional liquid chromatography requires orthogonal columns and/or separation principles in the first and second separation dimension. It is sometimes not straightforward to achieve. Chiral columns could expand the toolbox for 2D-LC, but are rarely exploited for this purpose, not least due to missing understanding of retention principles under non-chiral application conditions. To gain more insight, in this study Chiralpak ZWIX(+) and ZWIX(-), based on zwitterionic quinine and quinidine carbamate selectors, were carefully characterized by molecular dynamics simulations, lipophilicity/hydrophilicity measurements of selectors, pH-dependent -potential determinations, and chromatographic characterization in RPLC and HILIC modes combined with unsupervised principal component analysis to extract classification of these columns in comparison to a number of commercial benchmarks (RP, HILIC and mixed-mode columns). The results showed that these chiral columns can be classified as mixed-mode chromatography phases with balanced lipophilic-hydrophilic surface character, excess of negative net charge due to sulfonic acid groups (in spite of weakly basic quinuclidine and quinoline rings), and multimodal applicability (RP, HILIC and polar organic elution modes). Orthogonality mapping in comparison to a number of modern HILIC and mixed-mode columns revealed that Poroshell HILIC-Z (with a zwitterionic ligand on 2.7 mu m core-shell particles) can be beneficially combined as second dimension with the ZWIX column for comprehensive LC x LC. The online hyphenation of this 2D-LC system with complementary detection modalities including UV (DAD for chromophoric substances), charged aerosol detection (for universal detection and calibration of non-volatile analytes) and high-resolution mass spectrometry (ESI-QTOF-MS/MS for identification) provided an advanced method for comprehensive impurity profiling, applicable for instance for amino acid pharmaceutical products. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:168 / 179
页数:12
相关论文
共 56 条
[1]   Stable-bond polymeric reversed-phase/weak anion-exchange mixed-mode stationary phases obtained by simultaneous functionalization and crosslinking of a poly(3-mercaptopropyl)methylsiloxane-film on vinyl silica via thiol-ene double click reaction [J].
Baeurer, Stefanie ;
Zimmermann, Aleksandra ;
Woiwode, Ulrich ;
Sanchez-Munoz, Orlando L. ;
Kramer, Markus ;
Horak, Jeannie ;
Lindner, Wolfgang ;
Bicker, Wolfgang ;
Laemmerhofer, Michael .
JOURNAL OF CHROMATOGRAPHY A, 2019, 1593 :110-118
[2]   N-Propyl-N&-2-pyridylurea-modified silica as mixed-mode stationary phase with moderate weak anion exchange capacity and pH-dependent surface charge reversal [J].
Baeurer, Stefanie ;
Polnick, Stefan ;
Sanchez-Munoz, Orlando L. ;
Kramer, Markus ;
Laemmerhofer, Michael .
JOURNAL OF CHROMATOGRAPHY A, 2018, 1560 :45-54
[3]   Integrated modeling program, applied chemical theory (IMPACT) [J].
Banks, JL ;
Beard, HS ;
Cao, YX ;
Cho, AE ;
Damm, W ;
Farid, R ;
Felts, AK ;
Halgren, TA ;
Mainz, DT ;
Maple, JR ;
Murphy, R ;
Philipp, DM ;
Repasky, MP ;
Zhang, LY ;
Berne, BJ ;
Friesner, RA ;
Gallicchio, E ;
Levy, RM .
JOURNAL OF COMPUTATIONAL CHEMISTRY, 2005, 26 (16) :1752-1780
[4]   Mixed-mode stationary phases as a complementary selectivity concept in liquid chromatography-tandem mass spectrometry-based bioanalytical assays [J].
Bicker, Wolfgang ;
Laemmerhofer, Michael ;
Lindner, Wolfgang .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (01) :263-266
[5]  
Bidlingmeyer B., 2005, Pharmacopeial Forum, V21, P637
[6]   Comprehensive Liquid Chromatography and Other Liquid-Based Comprehensive Techniques Coupled to Mass Spectrometry in Food Analysis [J].
Cacciola, Francesco ;
Donato, Paola ;
Sciarrone, Danilo ;
Dugo, Paola ;
Mondello, Luigi .
ANALYTICAL CHEMISTRY, 2017, 89 (01) :414-429
[7]   A new measure of orthogonality for multi-dimensional chromatography [J].
Camenzuli, Michelle ;
Schoenmakers, Peter J. .
ANALYTICA CHIMICA ACTA, 2014, 838 :93-101
[8]   Dependence of Effective Peak Capacity in Comprehensive Two-Dimensional Separations on the Distribution of Peak Capacity between the Two Dimensions [J].
Davis, Joe M. ;
Stoll, Dwight R. ;
Carr, Peter W. .
ANALYTICAL CHEMISTRY, 2008, 80 (21) :8122-8134
[9]   Mixed-mode reversed phase/positively charged repulsion chromatography for intact protein separation [J].
Ding, Ling ;
Guo, Zhimou ;
Hu, Zhuo ;
Liang, Xinmiao .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 138 :63-69
[10]   Probing selectivity of mixed-mode reversed-phase/weak-anion-exchange liquid chromatography to advance method development [J].
Dores-Sousa, Jose Luis ;
De Vos, Jelle ;
Kok, Wim Th ;
Eeltink, Sebastiaan .