摘要
Purpose: To compare the accuracy of Barrett Universal II formula with other formulas (Holladay 2, Hoffer Q, and SRK/T formulas) in the prediction of postoperative refraction for pediatric intraocular lens implantation. Setting: Academic medical center/children's hospital, San Francisco, California. Design: Retrospective case series. Methods: Children aged 16 years or younger who underwent cataract extraction and IOL implantation (2012 to 2019) and had refraction assessed at 3 to 16 weeks postoperatively were included. Prediction error (PE) was calculated as postoperative mean spherical equivalent minus the target refraction. Mean, median, and standard deviation was calculated for PE and absolute PE. Performance across covariables (axial length, age, biometry type, keratometry, etc.) was studied, and a multivariate regression analysis was performed using a single prediction model for each formula. Results: Sixty-four eyes of 64 patients, aged 1.5 to 15.5 years, were included. Barrett Universal II formula had the lowest mean PE (-0.22 diopters [D]), SD (1.18 D), median PE (-0.26 D), and median absolute PE (0.71) compared with those of the other formulas. Holladay 2 formula performed similarly to Barrett Universal II formula, and SRK/T formula had the greatest mean PE (-0.50 D) and SD (1.22 D). Barrett Universal II formula predictions were stable across all variables. Conclusions: Barrett Universal II formula demonstrated similar or superior performance when compared with other formulas in this pediatric study. Holladay 2 formula performed similarly to Barrett Universal II formula, and SRK/T formula had the least reliable performance, across several key biometric characteristics. Although PEs can be highly variable in pediatric populations, this study supports Barrett Universal II formula as a reasonable and reliable option for lens power calculation in children, including those with extreme biometric measurements. J Cataract Refract Surg 2021; 47:599-605 Copyright (c) 2021 Published by Wolters Kluwer on behalf of ASCRS and ESCRS
引用
收藏
页码:599 / 605
页数:7
相关论文
共 50 条
  • [1] AN IMPROVED UNIVERSAL THEORETICAL FORMULA FOR INTRAOCULAR-LENS POWER PREDICTION
    BARRETT, GD
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (06): : 713 - 720
  • [2] Accuracy of Intraocular lens power calculation in pediatric traumatic cataract
    Goyal, Priya
    Tibrewal, Shailja
    Ganesh, Suma
    Rath, Soveeta
    Majumdar, Atanu
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (11) : 1605 - 1610
  • [3] Intraocular lens power calculation formula accuracy: Comparison of 12 formulas for a trifocal hydrophilic intraocular lens
    Rocha-de-Lossada, Carlos
    Colmenero-Reina, Elvira
    Flikier, David
    Castro-Alonso, Francisco-Javier
    Rodriguez-Raton, Alvaro
    Garcia-Madrona, Jose-Luis
    Peraza-Nieves, Jorge
    Sanchez-Gonzalez, Jose-Maria
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (06) : 2981 - 2988
  • [4] Accuracy of Intraocular Lens Power Calculation Formulas in Patients With Multifocal Intraocular Lens Implantation With Optic Capture in Berger Space for Pediatric Cataract
    Wang, Menghan
    Li, Dongfang
    Fan, Zheng
    Zhang, Jing
    Zhou, Jinyan
    Huang, Yusen
    JOURNAL OF PEDIATRIC OPHTHALMOLOGY & STRABISMUS, 2023, 60 (02) : 139 - +
  • [5] Intraocular lens power calculation in virgin eyes: Accuracy of the Barrett Universal II formula and a Ray tracing software
    Fernandez-Roses, Joaquim
    Lamarca, Jose
    Pinero, David P.
    Barraquer, Rafael, I
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (05) : 2954 - 2960
  • [6] Accuracy of Intraocular Lens Power Calculation in Pediatric Secondary Implantation: In-the-Bag Versus Sulcus Placement
    Liu, Zhenzhen
    Zou, Yingshi
    Yu, Yinglin
    Qu, Bo
    Jin, Ling
    Tan, Yuan
    Chen, Hui
    Xu, Jingmin
    Lin, Zhuoling
    Li, Jing
    Liu, Jianping
    Luo, Lixia
    Chen, Weirong
    Liu, Yizhi
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 249 : 137 - 143
  • [7] FACTORS INFLUENCING THE ACCURACY OF THE SRK FORMULA IN THE INTRAOCULAR-LENS POWER CALCULATION
    KALOGEROPOULOS, C
    ASPIOTIS, M
    STEFANIOTOU, M
    PSILAS, K
    DOCUMENTA OPHTHALMOLOGICA, 1994, 85 (03) : 223 - 242
  • [8] The SRKII formula in the calculation of intraocular lens power
    Nurözler, A
    Ünlü, N
    Yalvaç, IS
    Kasim, R
    Duman, S
    OPHTHALMOLOGICA, 1998, 212 (03) : 153 - 156
  • [9] Considerations of a thick lens formula for intraocular lens power calculation
    Langenbucher, Achim
    Hoffmann, Peter
    Cayless, Alan
    Gatinel, Damien
    Debellemaniere, Guillaume
    Wendelstein, Jascha
    Szentmary, Nora
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2024, 34 (04): : 620 - 631
  • [10] Accuracy of 8 intraocular lens power calculation formulas in pediatric cataract patients
    Pingjun Chang
    Lei Lin
    Zhangliang Li
    Li Wang
    Jinhai Huang
    Yun-e Zhao
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2020, 258 : 1123 - 1131