Francisella tularensis detection using magnetic labels and a magnetic biosensor based on frequency mixing

被引:38
作者
Meyer, Martin H. F.
Krause, Hans-Joachim
Hartmann, Markus
Miethe, Peter
Oster, Juergen
Keusgen, Michael [1 ]
机构
[1] Univ Marburg, Inst Pharmaceut Chem, D-35032 Marburg, Germany
[2] Res Ctr Juelich, Inst Bio & Nanosyst IBN2, Julich, Germany
[3] SENOVA GmbH, Jena, Germany
[4] Chemagen GmbH, Baesweiler, Germany
关键词
Francisella tularensis; tularemia; magnetic bead; biosensor; magnetic label;
D O I
10.1016/j.jmmm.2006.10.1175
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A biosensor that uses resonant coils with a special frequency-mixing technique and magnetic beads as detectable labels has been established for the detection of Francisella tularensis, the causative agent for tularemia. The detection principle is based on a sandwich immunoassay using an anti-Ft antibody for immunofiltration immobilized to ABICAP'(R) polyethylene filters, and biotinylated with streptavidin-coated magnetic beads as labels. The linear detection range of this biosensor was found to be 10(4)-10(6) cfu F tularensis lipopolysaccharide (LPS) per ml. Tested sample matrices were physiological PBS buffer and rabbit serum. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:259 / 263
页数:5
相关论文
共 23 条
  • [1] [Anonymous], 2000, RU Patent, Patent No. [2166751, EP 1262766]
  • [2] Detection and manipulation of biomolecules by magnetic carriers
    Brzeska, M
    Panhorst, M
    Kamp, PB
    Schotter, J
    Reiss, G
    Pühler, A
    Becker, A
    Brückl, H
    [J]. JOURNAL OF BIOTECHNOLOGY, 2004, 112 (1-2) : 25 - 33
  • [3] Detection of biological threat agents by real-time PCR: Comparison of assay performance on the RAPID, the LightCycler, and the smart cycler platforms
    Christensen, DR
    Hartman, LJ
    Loveless, BM
    Frye, MS
    Shipley, MA
    Bridge, DL
    Richards, MJ
    Kaplan, RS
    Garrison, J
    Baldwin, CD
    Kulesh, DA
    Norwood, DA
    [J]. CLINICAL CHEMISTRY, 2006, 52 (01) : 141 - 145
  • [4] Tularemia as a biological weapon - Medical and public health management
    Dennis, DT
    Inglesby, TV
    Henderson, DA
    Bartlett, JG
    Ascher, MS
    Eitzen, E
    Fine, AD
    Friedlander, AM
    Hauer, J
    Layton, M
    Lillibridge, SR
    McDade, JE
    Osterholm, MT
    O'Toole, T
    Parker, G
    Perl, TM
    Russell, PK
    Tonat, K
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 285 (21): : 2763 - 2773
  • [5] Planar Hall effect sensor for magnetic micro- and nanobead detection
    Ejsing, L
    Hansen, MF
    Menon, AK
    Ferreira, HA
    Graham, DL
    Freitas, PP
    [J]. APPLIED PHYSICS LETTERS, 2004, 84 (23) : 4729 - 4731
  • [6] Biodetection using magnetically labeled biomolecules and arrays of spin valve sensors (invited)
    Ferreira, HA
    Graham, DL
    Freitas, PP
    Cabral, JMS
    [J]. JOURNAL OF APPLIED PHYSICS, 2003, 93 (10) : 7281 - 7286
  • [7] Magnetic force-based multiplexed immunoassay using superparamagnetic nanoparticles in microfluidic channel
    Kim, KS
    Park, JK
    [J]. LAB ON A CHIP, 2005, 5 (06) : 657 - 664
  • [8] KRAUSE HJ, 2004, Patent No. 2004077044
  • [9] KRAUSE HJ, 2006, IN PRESS J MAGN MAGN
  • [10] KRAUSE HJ, 2003, Patent No. 103091327