Francisella tularensis detection using magnetic labels and a magnetic biosensor based on frequency mixing

被引:38
作者
Meyer, Martin H. F.
Krause, Hans-Joachim
Hartmann, Markus
Miethe, Peter
Oster, Juergen
Keusgen, Michael [1 ]
机构
[1] Univ Marburg, Inst Pharmaceut Chem, D-35032 Marburg, Germany
[2] Res Ctr Juelich, Inst Bio & Nanosyst IBN2, Julich, Germany
[3] SENOVA GmbH, Jena, Germany
[4] Chemagen GmbH, Baesweiler, Germany
关键词
Francisella tularensis; tularemia; magnetic bead; biosensor; magnetic label;
D O I
10.1016/j.jmmm.2006.10.1175
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A biosensor that uses resonant coils with a special frequency-mixing technique and magnetic beads as detectable labels has been established for the detection of Francisella tularensis, the causative agent for tularemia. The detection principle is based on a sandwich immunoassay using an anti-Ft antibody for immunofiltration immobilized to ABICAP'(R) polyethylene filters, and biotinylated with streptavidin-coated magnetic beads as labels. The linear detection range of this biosensor was found to be 10(4)-10(6) cfu F tularensis lipopolysaccharide (LPS) per ml. Tested sample matrices were physiological PBS buffer and rabbit serum. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:259 / 263
页数:5
相关论文
共 23 条
[1]  
[Anonymous], 2000, RU Patent, Patent No. [2166751, EP 1262766]
[2]   Detection and manipulation of biomolecules by magnetic carriers [J].
Brzeska, M ;
Panhorst, M ;
Kamp, PB ;
Schotter, J ;
Reiss, G ;
Pühler, A ;
Becker, A ;
Brückl, H .
JOURNAL OF BIOTECHNOLOGY, 2004, 112 (1-2) :25-33
[3]   Detection of biological threat agents by real-time PCR: Comparison of assay performance on the RAPID, the LightCycler, and the smart cycler platforms [J].
Christensen, DR ;
Hartman, LJ ;
Loveless, BM ;
Frye, MS ;
Shipley, MA ;
Bridge, DL ;
Richards, MJ ;
Kaplan, RS ;
Garrison, J ;
Baldwin, CD ;
Kulesh, DA ;
Norwood, DA .
CLINICAL CHEMISTRY, 2006, 52 (01) :141-145
[4]   Tularemia as a biological weapon - Medical and public health management [J].
Dennis, DT ;
Inglesby, TV ;
Henderson, DA ;
Bartlett, JG ;
Ascher, MS ;
Eitzen, E ;
Fine, AD ;
Friedlander, AM ;
Hauer, J ;
Layton, M ;
Lillibridge, SR ;
McDade, JE ;
Osterholm, MT ;
O'Toole, T ;
Parker, G ;
Perl, TM ;
Russell, PK ;
Tonat, K .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 285 (21) :2763-2773
[5]   Planar Hall effect sensor for magnetic micro- and nanobead detection [J].
Ejsing, L ;
Hansen, MF ;
Menon, AK ;
Ferreira, HA ;
Graham, DL ;
Freitas, PP .
APPLIED PHYSICS LETTERS, 2004, 84 (23) :4729-4731
[6]   Biodetection using magnetically labeled biomolecules and arrays of spin valve sensors (invited) [J].
Ferreira, HA ;
Graham, DL ;
Freitas, PP ;
Cabral, JMS .
JOURNAL OF APPLIED PHYSICS, 2003, 93 (10) :7281-7286
[7]   Magnetic force-based multiplexed immunoassay using superparamagnetic nanoparticles in microfluidic channel [J].
Kim, KS ;
Park, JK .
LAB ON A CHIP, 2005, 5 (06) :657-664
[8]  
KRAUSE HJ, 2004, Patent No. 2004077044
[9]  
KRAUSE HJ, 2006, IN PRESS J MAGN MAGN
[10]  
KRAUSE HJ, 2003, Patent No. 103091327