Percentage depth dose evaluation in heterogeneous media using thermoluminescent dosimetry

被引:19
作者
da Rosa, L. A. R. [2 ]
Cardoso, S. C. [1 ]
Campos, L. T. [2 ]
Alves, V. G. L. [1 ]
Batista, D. V. S. [3 ]
Facure, A. [4 ]
机构
[1] Univ Fed Rio de Janeiro, Inst Fis, IRD CNEN, BR-21941972 Rio De Janeiro, Brazil
[2] Univ Fed Rio de Janeiro, Inst Radioprotecao & Dosimetria, BR-21941972 Rio De Janeiro, Brazil
[3] INCA, Inst Nacl Canc, Rio De Janeiro, Brazil
[4] Comissao Nacl Energia Nucl, Rio De Janeiro, Brazil
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2010年 / 11卷 / 01期
关键词
thermoluminescent detector; lung heterogeneity; small field size; 15; MV; treatment planning system; MONTE-CARLO; STEREOTACTIC RADIOSURGERY; ENERGY; BEAMS; DISTRIBUTIONS; RADIOTHERAPY; ALGORITHMS; TRANSPORT; TLD-100; IMPACT;
D O I
10.1120/jacmp.v11i1.2947
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study is to investigate the influence of lung heterogeneity inside a soft tissue phantom on percentage depth dose (PDD). PDD curves were obtained experimentally using LiF: Mg,Ti (TLD-100) thermoluminescent detectors and applying Eclipse treatment planning system algorithms Batho, modified Batho (M-Batho or BMod), equivalent TAR (E-TAR or EQTAR), and anisotropic analytical algorithm (AAA) for a 15 MV photon beam and field sizes of 1 x 1, 2 x 2, 5 x 5, and 10 x 10 cm(2). Monte Carlo simulations were performed using the DOSRZnrc user code of EGSnrc. The experimental results agree with Monte Carlo simulations for all irradiation field sizes. Comparisons with Monte Carlo calculations show that the AAA algorithm provides the best simulations of PDD curves for all field sizes investigated. However, even this algorithm cannot accurately predict PDD values in the lung for field sizes of 1 x 1 and 2 x 2 cm(2). An overdos-age in the lung of about 40% and 20% is calculated by the AAA algorithm close to the interface soft tissue/lung for 1 x 1 and 2 x 2 cm(2) field sizes, respectively. It was demonstrated that differences of 100% between Monte Carlo results and the algorithms Batho, modified Batho, and equivalent TAR responses may exist inside the lung region for the 1 x 1 cm(2) field.
引用
收藏
页码:117 / 127
页数:11
相关论文
共 33 条
[11]  
*INT COMM RAD UN M, 1984, 37 ICRU MEAS
[12]   Comparison of inhomogeneity correction algorithms in small photon fields [J].
Jones, AO ;
Das, IJ .
MEDICAL PHYSICS, 2005, 32 (03) :766-776
[13]   A Monte Carlo study of IMRT beamlets in inhomogeneous media [J].
Jones, AO ;
Das, IJ ;
Jones, FL .
MEDICAL PHYSICS, 2003, 30 (03) :296-300
[14]  
Kawrakow I., 2000, PIRS701 NRCC
[15]  
Khan F. M., 2003, PHYS RAD THERAPY, V3rd
[16]   The value of the PinPoint ion chamber for characterization of small field segments used in intensity-modulated radiotherapy [J].
Martens, C ;
De Wagter, C ;
De Neve, W .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09) :2519-2530
[17]   ENERGY AND ANGULAR-DISTRIBUTIONS OF PHOTONS FROM MEDICAL LINEAR ACCELERATORS [J].
MOHAN, R ;
CHUI, C ;
LIDOFSKY, L .
MEDICAL PHYSICS, 1985, 12 (05) :592-597
[18]   Monte Carlo simulation of the Leksell gamma Knife®:: II.: Effects of heterogeneous versus homogeneous media for stereotactic radiosurgery [J].
Moskvin, V ;
Timmerman, R ;
DesRosiers, C ;
Randall, M ;
DesRosiers, P ;
Dittmer, P ;
Papiez, L .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (21) :4879-4895
[19]   MEASUREMENTS OF DOSE DISTRIBUTIONS IN SMALL BEAMS OF 6 MV X-RAYS [J].
RICE, RK ;
HANSEN, JL ;
SVENSSON, GK ;
SIDDON, RL .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (09) :1087-1099
[20]  
Rogers D., 2021, NRC user codes for EGSnrc, NRCC report PIRS-702 (RevC)