Coronary artery flow velocity is related to lumen area and regional left ventricular mass

被引:91
作者
Anderson, HV
Stokes, MJ
Leon, M
Abu-Halawa, SA
Stuart, Y
Kirkeeide, RL
机构
[1] Univ Texas, Hlth Sci Ctr, Div Cardiol, Houston, TX 77225 USA
[2] Hermann Hosp, Houston, TX USA
关键词
blood flow velocity; coronary circulation; coronary angiography;
D O I
10.1161/01.CIR.102.1.48
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Coronary flow velocity varies widely between individuals, even at rest. Because of this variation, indices with less apparent deviation, such as the ratio of hyperemic to resting velocity (coronary flow reserve), have been more commonly studied. We tested the hypothesis that the flow continuity principle could be used to model resting coronary flow. and we examined the resulting velocity relationship. Methods and Results-We studied coronary velocity in 59 patients using a Doppler wire to measure resting and hyperemic average peak velocities in the left anterior descending artery. Quantitative techniques were used to calculate lumen cross-sectional area and the lengths of all distal coronary branches. Branch lengths were used to estimate regional left Ventricular mass. We then calculated the ratio of lumen area to regional mass (A/m). Regional perfusion was estimated from the double product of heart rate and systolic blood pressure. Resting velocity (V) varied inversely with A/m ratio [V=46.5/(A/m); r=0.68, P<0.001]. Disease in the left anterior descending artery was categorized as none or luminal irregularities only (n=22), mild (n=15), or moderate (n=22). The A/m ratio declined across these groups (8.7 +/- 4.0, 8.5 +/- 6.2, and 5.6 +/- 3.0 mm(2)/100 g, respectively; P<0.04), and the resting average peak velocity increased (27 +/- 16, 33 +/- 11, and 37 +/- 20 cm/s, respectively; P=0.06). Conclusions-Resting coronary artery flow velocity is inversely related to the ratio of lumen area to regional left Ventricular mass. Higher resting velocities are found when insufficient lumen size exists for the distal myocardial bed, as occurs with diffuse mild or moderate coronary atherosclerosis.
引用
收藏
页码:48 / 54
页数:7
相关论文
共 34 条
  • [1] LOSS OF FLOW-DEPENDENT CORONARY-ARTERY DILATATION IN PATIENTS WITH HYPERTENSION
    ANTONY, I
    LEREBOURS, G
    NITENBERG, A
    [J]. CIRCULATION, 1995, 91 (06) : 1624 - 1628
  • [2] BALLER D, 1979, Clinical Cardiology, V2, P317
  • [3] Current concepts of coronary flow reserve for clinical decision making during cardiac catheterisation
    Baumgart, D
    Haude, M
    Liu, FQ
    Ge, JB
    Goerge, G
    Erbel, R
    [J]. AMERICAN HEART JOURNAL, 1998, 136 (01) : 136 - 149
  • [4] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [5] Buchi M, 1990, Int J Card Imaging, V5, P93, DOI 10.1007/BF01833978
  • [6] EARLY DETECTION OF ABNORMAL CORONARY FLOW RESERVE IN ASYMPTOMATIC MEN AT HIGH-RISK FOR CORONARY-ARTERY DISEASE USING POSITRON EMISSION TOMOGRAPHY
    DAYANIKLI, F
    GRAMBOW, D
    MUZIK, O
    MOSCA, L
    RUBENFIRE, M
    SCHWAIGER, M
    [J]. CIRCULATION, 1994, 90 (02) : 808 - 817
  • [7] Accuracy of Doppler catheter measurements: Effect of inhomogeneous beam power distribution on mean and peak velocity
    Denardo, SJ
    Talbot, L
    Hargrave, VK
    Selfridge, AR
    Ports, TA
    Yock, PG
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 283 - 292
  • [8] Assessing the Hemodynamic Significance of Coronary Artery Stenoses: Analysis of Translesional Pressure-Flow Velocity Relations in Patients
    Donohue, Thomas J.
    Kern, Morton J.
    Aguirre, Frank V.
    Bach, Richard G.
    Wolford, Thomas
    Bell, Calvin A.
    Segal, Jerome
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (02) : 449 - 458
  • [9] VALIDATION OF A DOPPLER GUIDE WIRE FOR INTRAVASCULAR MEASUREMENT OF CORONARY-ARTERY FLOW VELOCITY
    DOUCETTE, JW
    CORL, PD
    PAYNE, HM
    FLYNN, AE
    GOTO, M
    NASSI, M
    SEGAL, J
    [J]. CIRCULATION, 1992, 85 (05) : 1899 - 1911
  • [10] Significance of automated stenosis detection during quantitative angiography - Insights gained from intracoronary ultrasound imaging
    Escaned, J
    Baptista, J
    DiMario, C
    Haase, J
    Ozaki, Y
    Linker, DT
    deFeyter, PJ
    Roelandt, JRTC
    Serruys, PW
    [J]. CIRCULATION, 1996, 94 (05) : 966 - 972