Mass transfer coefficients in a Kuhni extraction column

被引:53
作者
Hemmati, Alireza [1 ]
Torab-Mostaedi, Meisam [2 ]
Asadollahzadeh, Mehdi [2 ]
机构
[1] Islamic Azad Univ, Dept Chem Engn, Fac Engn, South Tehran Branch, Tehran, Iran
[2] Nucl Sci & Technol Res Inst, Nucl Fuel Cycle Res Sch, Tehran, Iran
关键词
Kuhni extraction column; Mass transfer coefficient; Axial diffusion model; Effective diffusivity; Enhancement factor; LIQUID-LIQUID-EXTRACTION; EFFECTIVE DIFFUSIVITY; PREDICTION; DROPS;
D O I
10.1016/j.cherd.2014.07.011
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Mass transfer performance has been presented for a 117 diameter Kuhni extraction column using axial diffusion model for two different liquid-liquid systems. The influence of operating variables including the rotor speed as well as the continuous and dispersed phase flowrates on the volumetric overall mass transfer coefficients is investigated. Effective diffusivity is substituted for molecular diffusivity in the Grober equation for prediction of dispersed phase overall mass transfer coefficients. The enhancement factor is determined experimentally and there from an empirical correlation is derived for prediction of enhancement factor in terms of Reynolds number and dispersed phase holdup. The prediction of overall mass transfer coefficients from the presented equation is in good agreement with experimental data. (C) 2014 The Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:747 / 754
页数:8
相关论文
共 50 条
  • [21] Transient modeling of zinc extraction with D2EHPA in a Kuhni column
    Neto, Artur Pereira
    Mansur, Marcelo Borges
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2013, 91 (12) : 2323 - 2332
  • [22] Experimental mass transfer coefficients in a pilot plant multistage column extractor
    Mehdi Asadollahzadeh
    Ahad Ghaemi
    Meisam Torab-Mostaedi
    Shahrokh Shahhosseini
    ChineseJournalofChemicalEngineering, 2016, 24 (08) : 989 - 999
  • [23] Hydrodynamics and mass transfer coefficients for a modified Raschig ring packed column
    I. Mamaliga
    D. Sidor
    C. Condurat
    E. T. Iacob Tudose
    Heat and Mass Transfer, 2014, 50 : 1385 - 1392
  • [24] The Effect of Size and Concentration of Nanoparticles on the Mass Transfer Coefficients in Irregular Packed Liquid-Liquid Extraction Columns
    Nematbakhsh, Gita
    Rahbar-Kelishami, Ahmad
    CHEMICAL ENGINEERING COMMUNICATIONS, 2015, 202 (11) : 1493 - 1501
  • [25] Axial Variation of Mass Transfer Volumetric Coefficients in Bubble Column Bioreactors
    Leon-Becerril, Elizabeth
    Maya-Yescas, Rafael
    CHEMICAL PRODUCT AND PROCESS MODELING, 2010, 5 (01):
  • [26] Modeling the axial distribution of mass transfer coefficient in an agitated-pulsed extraction column
    Tan, Boren
    Xu, Ziyang
    Wang, Yong
    Zhang, Yanlin
    Hu, Yongqi
    Qi, Tao
    AICHE JOURNAL, 2022, 68 (06)
  • [27] Prediction of mass transfer coefficients in an asymmetric rotating disk contactor using effective diffusivity
    Torab-Mostaedi, Meisam
    Asadollahzadeh, Mehdi
    Safdari, Jaber
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2017, 25 (03) : 288 - 293
  • [28] The investigation of mass transfer coefficients in a pulsed regular packed column applying SiO2 nanoparticles
    Moghadam, Ensiyeh Hosseini
    Bahmanyar, Hossein
    Heshmatifar, Fatemeh
    Kasaie, Maryam
    Ziaei-Azad, Hessam
    SEPARATION AND PURIFICATION TECHNOLOGY, 2017, 176 : 15 - 22
  • [29] The effects of a surfactant on the mass transfer in spray-tower extraction column
    Chen, LH
    Lee, YL
    CHEMICAL ENGINEERING JOURNAL, 1999, 73 (01) : 77 - 81
  • [30] The influence of silica nanoparticles on hydrodynamics and mass transfer in spray liquid-liquid extraction column
    Ashrafmansouri, Seyedeh-Saba
    Esfahany, Mohsen Nasr
    SEPARATION AND PURIFICATION TECHNOLOGY, 2015, 151 : 74 - 81