Automated versus Manual Data Extraction of the Padua Prediction Score for Venous Thromboembolism Risk in Hospitalized Older Adults

被引:6
|
作者
Pavon, Juliessa M. [1 ,2 ,3 ]
Sloane, Richard J. [1 ,2 ,3 ]
Pieper, Carl F. [1 ,2 ,3 ]
Colon-Emeric, Cathleen S. [1 ,2 ,3 ]
Cohen, Harvey J. [1 ,2 ,3 ]
Gallagher, David [1 ]
Morey, Miriam C. [1 ,2 ,3 ]
McCarty, Midori [1 ]
Ortel, Thomas L. [1 ]
Hastings, Susan N. [1 ,2 ,3 ,4 ]
机构
[1] Duke Univ, Durham, NC USA
[2] Durham Vet Affairs Med Ctr, Geriatr Res Educ Clin Ctr, Durham, NC USA
[3] Duke Univ, Claude D Pepper Ctr, Durham, NC USA
[4] Durham Vet Affairs Hlth Care Syst, Hlth Serv Res & Dev Ctr Innovat, Durham, NC USA
来源
APPLIED CLINICAL INFORMATICS | 2018年 / 9卷 / 03期
关键词
decision support algorithm; venous thromboembolism; geriatrics; electronic health record and systems; inpatient; ADMINISTRATIVE DATA; AMERICAN-COLLEGE; PROPHYLAXIS; VTE; VALIDATION; ALGORITHM; ACCURACY; MEDICINE; VALIDITY; ICD-9-CM;
D O I
10.1055/s-0038-1670678
中图分类号
R-058 [];
学科分类号
摘要
Objective Venous thromboembolism (VTE) prophylaxis is an important consideration for hospitalized older adults, and the Padua Prediction Score (PPS) is a risk prediction tool used to prioritize patient selection. We developed an automated PPS (APPS) algorithm using electronic health record (EHR) data. This study examines the accuracy of APPS and its individual components versus manual data extraction. Methods This is a retrospective cohort study of hospitalized general internal medicine patients, aged 70 and over. Fourteen clinical variables were collected to determine their PPS; APPS used EHR data exports from health system databases, and a trained abstractor performed manual chart abstractions. We calculated sensitivity and specificity of the APPS, using manual PPS as the gold standard for classifying risk category (low vs. high). We also examined performance characteristics of the APPS for individual variables. Results PPS was calculated by both methods on 311 individuals. The mean PPS was 3.6 (standard deviation, 1.8) for manual abstraction and 2.8 (1.4) for APPS. In detecting patients at high risk for VTE, the sensitivity and specificity of the APPS algorithm were 46 and 94%, respectively. The sensitivity for APPS was poor (range: 6-34%) for detecting acute conditions (i.e., acute myocardial infarction), moderate (range: 52-74%) for chronic conditions (i.e., heart failure), and excellent (range: 94-98%) for conditions of obesity and restricted mobility. Specificity of the automated extraction method for each PPS variable was > 87%. Conclusion APPS as a stand-alone tool was suboptimal for classifying risk of VTE occurrence. The APPS accurately identified high risk patients (true positives), but lower scores were considered indeterminate.
引用
收藏
页码:743 / 751
页数:9
相关论文
共 50 条
  • [21] Assessing the Caprini Score for Risk Assessment of Venous Thromboembolism in Hospitalized Medical Patients
    Grant, Paul J.
    Greene, M. Todd
    Chopra, Vineet
    Bernstein, Steven J.
    Hofer, Timothy P.
    Flanders, Scott A.
    AMERICAN JOURNAL OF MEDICINE, 2016, 129 (05): : 528 - 535
  • [22] RISK-Prediction MODEL for DEVELOPMENT of Venous Thromboembolism In HOSPITALIZED CHILDREN
    Mahajerin, Arash
    Fallon, Robert
    Eckert, George
    Heiny, Mark
    Vik, Terry
    Sharathkumar, Anjali
    BLOOD, 2011, 118 (21) : 990 - 990
  • [23] Is objective mobility data associated with pharmacologic venous thromboembolism (VTE) prophylaxis use among hospitalized older adults?
    Pavon, J. M.
    Sloane, R.
    Pieper, C.
    Colon-Emeric, C. S.
    Gallagher, D.
    Cohen, H.
    Hall, K.
    Morey, M.
    McCarty, M.
    Ortel, T.
    Hastings, S. N.
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2018, 66 : S155 - S155
  • [24] Comparison between Caprini and Padua risk assessment models for hospitalized medical patients at risk for venous thromboembolism: a retrospective study
    Liu, Xiaohan
    Liu, Chengyuan
    Chen, Xi
    Wu, Wenwen
    Lu, Gendi
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2016, 23 (04) : 538 - 543
  • [25] A risk score for prediction of recurrence in patients with unprovoked venous thromboembolism (DAMOVES)
    Franco Moreno, A. I.
    Garcia Navarro, M. J.
    Ortiz Sanchez, J.
    Martin Diaz, R. M.
    Madronal Cerezo, E.
    de Ancos Aracil, C. L.
    Cabello Clotet, N.
    Perales Fraile, I.
    Gimeno Garcia, S.
    Montero Hernandez, C.
    Zapatero Gaviria, A.
    Ruiz Giardin, J. M.
    EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2016, 29 : 59 - 64
  • [26] A risk score for prediction of recurrence in patients with unprovoked venous thromboembolism (damoves)
    Moreno, A. I. F.
    Navarro, M. J. G.
    Sanchez, J. O.
    Diaz, R. M. M.
    Cerezo, E. M.
    de Ancos Aracil, C. L.
    Diaz, V. M.
    Garcia, A. G.
    Hernandez, C. M.
    Arponen, S.
    Clotet, N. C.
    Giardin, J. M. R.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2015, 13 : 682 - 682
  • [27] A Multifactorial Falls Risk Prediction Model for Hospitalized Older Adults
    GholamHosseini, Hamid
    Baig, Mirza Mansoor
    Connolly, Martin J.
    Linden, Maria
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 3484 - 3487
  • [28] Performance of Khorana Risk Score for Prediction of Venous Thromboembolism in Patients With Lung Cancer
    Havlucu, Yavuz
    Kizilirmak, Deniz
    EUROPEAN RESPIRATORY JOURNAL, 2019, 54
  • [29] PERFORMANCE OF KHORANA RISK SCORE FOR PREDICTION OF VENOUS THROMBOEMBOLISM IN PATIENTS OF HEPATOCELLULAR CARCINOMA
    Wang, Yuchen
    Attar, Bashar M.
    Fuentes, Harry
    Yu, Jie
    Simons-Linares, C. Roberto
    Tafur, Alfonso J.
    GASTROENTEROLOGY, 2017, 152 (05) : S1179 - S1179
  • [30] Performance of Khorana Risk Score for Prediction of Venous Thromboembolism in Patients With Hepatocellular Carcinoma
    Wang, Y.
    Attar, B. M.
    Fuentes, H. E.
    Yu, J.
    Zhang, Huiyuan
    Tafur, A. J.
    CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2018, 24 (03) : 471 - 476